| 1 | Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar. |
| 2 | Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc.15 cm thickness (below or above ground level) and removing from site all as specified and directed. |
| 3 | M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors. |
| 4 | M&L for Virified Ceramic tiles 9-10 mm thick light shade (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm,as in floors etc set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:4 (Tile pattern and decoration may be as suggested by Engineer-in-charge). |
| 5 | M&L for Virified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, as in vertical surface like skirting /dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat 10 mm thick in CM 1:3 |
| 6 | M & L for 18 to 20 mm thick machine cut green marbel stone in single piece in window/opening (Jambs/Cills) laid over cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10 mm thick plastering with cement mortar 1 : 3 including necessary adhesive complete all as specified |
| 7 | M&L Granite (of any type and colour) work (table rubbed and polished) 18 to 20mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed. |
| 8 | S&F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 9 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubularsections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 10 | S&F 4.00mm thick sheet glass, selected ordinary quality and glazing with rubber beading or with glazing clips exc 0.5 sq. m in each pane including solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, all as specified and directed. |
| 11 | M&L for 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/Angle iron frame/PVC door frame with screw complete all as specified and directed. |
| 12 | S & F 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed |
| 13 | S & F 150 mm size extruded aluminium alloy handles, febricated type anodised |
| 14 | S&F in repair 18mm thick HDHMR BOARD exterior grade including any coloured prelaminated sheet of required thickness over HDHMR board, anti fungal, moisture resistance, anti borer as per IS 14587 for frame and shutter for kitchen cabinets/cupboards etc all as per specified and directed by Engr-in-charge. Note: sample as approved by GE. Make: Action Tessa/Greenply/Century. |
| 15 | S&F in repair 18mm thick HDHMR BOARD exterior grade including white coloured prelaminated sheet of required thickness over HDHMR board, anti fungal, moisture resistance, anti borer as per IS 14587 for frame and shutter for kitchen cabinets/cupboards etc all as per specified and directed by Engr-in-charge. Note: sample as approved by GE. Make: Action Tessa/Greenply/Century. |
| 16 | S&F magnet door stopper of rectangular size for PVC cabinets including all fittings fixed complete all as specified and directed. |
| 17 | S & F SS W Hinges SS 202 Grade steel Rust Resistance , for fixing cup boards shutters sizes of hinges 3\\" to 4\\" and 1.5 mm thickness, suitable for 18 mm thick cabinets shutters complete all as specified and directed |
| 18 | S&F 100 mm Pull door handles, chrome finish, Stainless steel of SS 304 grade all as per specified and directed by Engr-in-charge. Note: sample as approved by EIC/GE |
| 19 | S & F in repairs 20mm dia brass chromium plated tubular towel rail complete. |
| 20 | S & F for mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete confirming to grade Fe 410-W (Gde- E- 250) quality-A, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 21 | Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge. |
| 22 | S & F 20 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 23 | Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge. |
| 24 | S & F 20mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed. |
| 25 | S & F in 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall all as specified and as directed. |
| 26 | S & F in 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed. |
| 27 | S & F in 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall all as specified and as directed. |
| 28 | S & F in 75mm bore PVC (SWR) bends any radius all as specified and as directed. |
| 29 | S & F in 75mm bore PVC (SWR) bends any radius with oval access doors all as specified and as directed. |
| 30 | S & F in 75mm PVC (SWR) floor trap, including jointing with solvent all as specified and as directed. |
| 31 | S&F in grating 150mmx150mm made out of stainless steel complete all as specified and directed. |
| 32 | S & F in 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal or with parallel branches with access door all as specified and as directed |
| 33 | S & F in 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal or with parallel branches with access door all as specified and as directed |
| 34 | S & F stack clamps made out of 50mm x 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 75mm bore pipe all as specified and as directed |
| 35 | S & F in repairs 15mm bore chromium plated fancy type bib tap long body, screwed down, high pressure for iron pipe or for brass ferrule |
| 36 | S & F CP wall mixer three in one system for mixing hot and cold water screwed down for iron pipe 15 mm bore and fixed complete all as specified and directed. Make Prayag or equivelent make. |
| 37 | S & F in repairs stop valves/Angle valve15mm bore fancy type chromium plated screwed both ends for iron pipe or for unions and fixed |
| 38 | S & F in repairs 20mm dia bore gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed |
| 39 | S&F 32 mm bore low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2 as in waste pipe |
| 40 | S&F in vitreous china Wash hand basin, white , flat back size 450x300 mm except taps, CP waste coupling but incl brackets all as specified. Make cera/Hindware |
| 41 | S&F in brass CP centre hole basin mixer for mixing hot & cold water three way screwed down for iron pipe 15mm bore and fixed complete. |
| 42 | S & F 32 mm dia stainless steel waste coupling for wash hand basin all as specified and directed. Make : Prayag or equivalant. |
| 43 | S & F in repair PVC connections 15mm size with PTMT nuts of length 450mm |
| 44 | S&F in 350x450mm size cabinet mirror rectangular shape with 4mm thick selected quality mirror and PTMT frame with openable door shutter with PTMT frame outside mirror as complete.Make : Prayag & equivalent. |
| 45 | S&F in repairs sinks made of stainless steel 1mm thick laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever bracket and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified. |
| 46 | S& F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. |
| 47 | Demolition of reinforced cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work |
| 48 | M&L Cement concrete type B1 1:2:4 (20 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges. |
| 49 | Taking down cement plaster on brick/concrete surface including racking out joints hacking for key scrubbing down with water etc. |
| 50 | Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc, |
| 51 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 |
| 52 | S&F 40mm bore UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe |
| 53 | M & L Rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement) |
| 54 | M & L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of 2mm average thickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed. |
| 55 | M&L for Providing reinforced cement concrete (nominal mix) Type B1, 1:2::4 (using 20 mm stone Aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work complete all as specified and directed. Note. (reinforcement shall be measured and paid separately) |
| 56 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specifed and as directed. |
| 57 | M & L for complete removal of old existing treatment completely by scrapping and or rubbing of wall and applying two coats of oil bound distemper over a coat of 2mm average thickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed. |
| 58 | M & L for complete removal of old existing treatment completely by scrapping and or rubbing of ceiling and applying two coats of oil bound distemper over a coat of 2mm average thickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed. |
| 59 | Taking down carefully existing unserviceable copper/aluminium point wiring (light, fan, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators, etc ( except tube light fittings), removing materials for taking credit and making good disturbed surface of wall, floors, etc complete all as directed by Eng-in-Charge. |
| 60 | Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity. |
| 61 | M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC Conduit and all accessories Concealed in walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed for the following:- |
| 62 | One light point controlled by one switch. |
| 63 | One ceiling fan point controlled by one switch and fan regulator. |
| 64 | One exhaust fan point controlled by one switch. |
| 65 | One 3 pin socket outlet 5 Amps independent board. |
| 66 | One 3 pin socket outlet 5 Amps on the same board with other switch. |
| 67 | One Wall fan point controlled by one switch and fan regulator. |
| 68 | All as per item No. 61 here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 2.5 sqmm PVC insulated multistranded flexible copper conductor for one independent 6 pin 16 Amp socket. |
| 69 | S&F Modular switch, one way, 6 Amp 230, 1 module all as specified and directed by Engr in charge. |
| 70 | S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt |
| 71 | S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt . |
| 72 | S&F socket Modular 6 Amp-2/3 pin combined 2 module |
| 73 | S & F ceiling rose surface polycarbonate body three terminal. |
| 74 | S&F Modular lamp holder Polycarbonate type with back plate suitable for Batten fitting Suitable for B22 type bulb. |
| 75 | S&F modular fan step regulator 120W 2 module. |
| 76 | S & F of BLDC White colour ceiling fan complete with blades and rod from existing roof / trus to fall ceiling, and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE,Winding material 100 % copper ,350RPM air velocity 215m3/min,anti rust blades five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor. |
| 77 | Supply and fix of LED light fitting 1X20Watt, 4 feet 220 Volt AC , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9, decorative box type with drivers, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old unserviceable existing light fitting complete all as specified and directed. Note : Warrenty on light should be of minimum 03 Years Provided by the contractor. |
| 78 | Supply and fix of LED light fitting 1X10Watt, 2 feet 220 Volt AC , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9, decorative box type with drivers, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old unserviceable existing light fitting complete all as specified and directed. Note : Warrenty on light should be of minimum 03 Years Provided by the contractor. |
| 79 | S&F LED bulb B22 9 watt inverter bulb ,lumin efficency 900 lumin/watt in normal mode and 350 lumin/watt in power backup mode,CRI ≥80,CCT-6500K ,surge protection upto 4KV,Voltage Protection upto 400 volt,PF ≥ 0.9 suitable for batten holder fitting complete all as specified and directed by Engr in charge.Note Warrenty on light should be of minimum 02 Years. |
| 80 | Taking down and refixing connecting same electric meter SP up to 60 amp incl S & F suitable new board close recessed type of suitable size and making good to disturbed surface and matching with the existing colour of wall. All as specified and directed by engr in charge. |
| 81 | Supply and Fix Wall mounted fan silent type steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers, 50Hz, RPM 1200, copper winding of sweep 300mm including cutting of suitable size holes on existing wall and making good disturbed work to match the existing surfaces and exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed |
| 82 | S & F of exhaust fan of white colour made of sturdy engineering PVC complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, noise level 40-45dB ,water resistant ,copper winding of sweep 250mm including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed.Note : 1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. complete all as specified and directed 2. Making suitable size of hole on wall for fixing the exhaust fan .3. 02 years guarantee to be provided by the contractor. |
| 83 | S&F Modular AC box metal enclosure with socket plug top and MCB SP 25 Amps flush mounting enclosure complete all as directed by Engineer-in-Charge |
| 84 | S & F Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.Note : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 85 | S & F Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.Note : Four runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 86 | S&F double door metallic sheet metal enclosure DB double door VTPN suitable for housing 125 MCCB as incomer 4 Way 415 Volts with 160 Amps rated bus bars. |
| 87 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used Triple pole and neutral 4 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed |
| 88 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 4 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed |
| 89 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed |
| 90 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 16 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed |
| 91 | S & F MCB single pole, having rupturing 10KA, 6 amps to 32 amps as ordered 240 Volts (series 'c' ) |
| 92 | S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered.(series 'c') |
| 93 | S&F testing and commissioning of MCB TPN 40 to 100 Amps,415 volt 50 Hz,10ka in accordance with IEC 60947- 2 having C-curve characteristics connected with suitable lugs.All as specified and directed by Engr-in charge |
| 94 | S&F testing and commissioning of MCB TP25 to 63 Amps ,415 volt 50 Hz,10ka in accordance with IEC 60947- 2 having C-curve characteristics connected with suitable lugs.All as specified and directed by Engr-in charge |
| 95 | S & F MCCB 125 Amp , 10KA, 240/415 V 4 pole Thermally and Magnetic Adjustable complete all as specified and directed. by Engr-in charge |
| 96 | S & F of Inverter LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers complete complete all as specified and directed |
| 97 | Taking down existing earthing and M & L Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes :-(a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing work is not found below 3Ω then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative. Please Enable Macros to View BoQ information |