| 1 | Demolition of brickwork or stone work/boulder masonary built in cement mortar or cement lime mortar complete all as specified and directed. |
| 2 | Material and Labour for precast cement concrete 1:3:6, type C-1, (20mm graded stone aggregate ) masonary with solid blocks, exc 10cm in width and setting in cement mortar (1:6) complete all as specified and directed. |
| 3 | All as per item No 2 above but except block recovered from demolition complete all as specified and directed. |
| 4 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 5 | Material and Labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement morter 1:4 complete all as specified and as directed. |
| 6 | Material and Labour for preparation of new undecorated surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 7 | Dismantling fencing, wire mesh any type complete all as specified and directed by Engr in Charge |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for in any position complete all as specified and directed by Engr in Charge. |
| 9 | Supply and Fix Mild steel for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed |
| 10 | Material and Labour for cement concrete in foundation PCC 1:3:6 type C2 using 40mm graded stone agg for fencing post etc complete all as specified and directed |
| 11 | Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed. |
| 12 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 13 | Material and Labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | Supply and Fix in repairs galvanised 2 strand barbed wire 2.24mm dia of wire and 2mm dia of barbed at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provn of galvanised MS wire staples or steel pins etc complete all as specified and directed |
| 15 | All as per item No. 14 here in before but restraining resecuring old fence including making good staples etc only all old wire fit for reuse complete all as specified and directed |
| 16 | Supply and Fix in repair framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe 290 Gde-E-165 complete all as specified and directed |
| 17 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed |
| 18 | Material and Labour for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 19 | Supply and Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old Roof sheet CGI/ PGI Sheet complete all as specified and directed by Engineer-in-charge. |
| 20 | Supply and Fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old Roof sheet CGI/ PGI Sheet complete all as specified and directed. |
| 21 | S & F fiber glass reinforced translucent corrugated sheeting with two corrugations side help fixed with coach screw and washer in roof , wall etc. including dismantling of old Roof sheet CGI/ PGI Sheet complete all as specified and directed. |
| 22 | Material and Labour for preparation of untreated new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint ( 1st grade quality ) over a coat of red oxide primer complete all as specified and as directed. |
| 23 | Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed |
| 24 | Material and Labour for cement concrete 1:4:8 type D-2 (40mm graded stone aggregate) 75 mm thick in sub base or similar items complete all as specified and directed. |
| 25 | Material and Labour for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed |
| 26 | Material and Labour for 80mm thick coloured rubburised, glossy finish machine pressed interlocking pattern paver block any shape and size conforming to IS 15658-2006 of M-40 Grade complete all as specified and directed by Engineer-in Charge. |
| 27 | Supply and Fix Pre Polished Chequered cement concrete tiles glossy and rubburised finish 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in CM 1:6 under tiles incl complete all as specified and directed by Engineer-in Charge. |
| 28 | Material and Labour for PCC 1:3:6 type C-1 , 75 mm thick as in plinth protection, Path, floor complete all as specified and directed |
| 29 | Material and Labour for Cement concrete (1:2:4) type B2 (40 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 30 | Extra for fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed |
| 31 | Demolition of cement concrete (re inforced) in roof floors, beams, staircase, landings, chajjas, pillars , cover slab etc and similar suspended works and removing materials from site of work complete all as specified and directed |
| 32 | Material and Labour for precast cement concrete 1:2:4 type B-1 (20mm graded agg) set in CM 1:6 as in cover slabs for manholes etc complete all as specified and directed |
| 33 | Supply and Fix TMT bars 6 to 8mm dia bar, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 34 | Demolition of Stone slabs and tiles of any description or thickness laid bedded and pointed in cement mortar in floors, aprons etc complete all as specified and directed |
| 35 | Material and Labour for Coloured Glazed ceramic tiles engraved textrure type or plain in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick plastering in cm 1:4 complete all as specified and directed |
| 36 | Material and Labour for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete fixed over and including backing coat of 10mm thick in CM 1:4 complete all as specified and directed |
| 37 | Dismantling wall and ceilihg boards (Fiber pulp, insulation etc or insulation boards any thickness including cover fillets complete all as specified and directed |
| 38 | Supply and Fix 5 mm thick colour of any selected design hollow PVC wall cladding strips interlocked to each other fitted to wall including PVC 'U' shapes at top/ bottom and PVC angles at windows/door openings all as per manufacturer’s fixing instructions complete all as specified and directed. |
| 39 | Supply and Fix 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall and make PVC frame/grid manufacturers instruction and complete all as specified and directed by the Engr-in-Charge. Please Enable Macros to View BoQ information |