| 1 | Demolition of stone/ boulder masonry, block masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlars facings, dressed stonework and precast concrete articles etc all as specified and directed. |
| 2 | M&L for providing precast cement concrete block masonry with solid blocks exceeding 10cm width, type C-1, using 20mm graded stone aggregate and set in cement mortar (1:6) complete all as specified and directed. |
| 3 | Description all as per item No.02 above but except precast blocks i.e using serviceable precast blocks obtained from item No 01 herein before all as specified and directed. |
| 4 | M&L for walling of random rubble, masonry uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1: 6 all as specified and directed. |
| 5 | Description all as per item No.04 above but except stone i.e using serviceable stone obtained from item No 01 herein before all as specified and directed |
| 6 | M&L for Flush pointing to block in course or ashlar masonry on concrete block walling in CM 1:4 complete all specified and directed |
| 7 | M&L for Raised pointing to Random or polygonal rubble uncoursed masonry or concrete block walling or brought up to courses in CM 1:4 |
| 8 | M&L for RCC (1:2:4) type-B1 using 20 mm graded stone aggregate as in lintels up to 1.5 m clear span, sills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs etc complete all as specified and directed. Note: Reinforcement shall be measured and paid separately. |
| 9 | Rectifying complaints of bathroom / kitchen / WHB / urinals / WCs of any pattern by cleaning the blockage of gully trap and Nahani trap and make it fully functional by flushing with sufficient water including disposal of sludge etc away from residential area and burying in borrow pits complete all as specified and directed. Notes:- (a) Earth work if any and making good to disturbed surface shall be deemed to be included in unit rate. (b)Unit rate quoted shall include taking out sludge away from residential area and burying in borrow pits. (c) The payment shall be done by complaint wise. (d) The period of rectifying each complaints is maximum 48 hrs and in case of failure to rectify the complaint in the stipulated period the necessary recovery at the rate of Rs 150 / per day per complaint shall be deducted from next due to contractor without any notice. (e) The contractor shall provide cleaning personal along with tools, bucket ,etc to rectify the complaints. |
| 10 | M&L for removal of blockage and cleaning of sewage lines of 100 mm bore by rodding from manholes to manholes or manholes to cleaning eyes, taking out all debris, sludges and solid materials from sewage lines and removing outside MD land and well flushing with water complete all as specified and directed. |
| 11 | Description all as per item No.10 herein before but 150 mm bore. |
| 12 | Description all as per item No.10 herein before but 200 mm bore. |
| 13 | Description all as per item No.10 herein before but 250 mm bore. |
| 14 | Description all as per item No.10 herein before but 300 mm bore. |
| 15 | M&L for removal of blockage and cleaning of manholes of size 800 mm x 800 mm and up to a depth of 1 m by removing sludge/ liquid foul/ waste etc complete and ensuring smooth flow of sewage including sprinkling of bleaching powder after cleaning of manholes and disposing the waste outside Defence land all as directed. |
| 16 | Description all as per item No. 15.00 herein before but manhole of size 900 mm x 1200 mm and depth of manhole exc. 1 m and not exceeding 2 m. |
| 17 | Description all as per item No. 15.00 herein before but manhole of size 1400 mm dia and depth of manhole exc. 2 m and not exceeding 3 m. |
| 18 | Description all as per item No. 15.00 herein before but manhole of size 1400 mm dia and depth of manhole exceeding 3 m and not exceeding 4 m. |
| 19 | Description all as per item No. 15.00 herein before but manhole of size 1400 mm dia and depth of manhole exceeding 4 m and not exceeding 5 m. |
| 20 | Cleaning of septic tanks/Man hole/Soakage Well by bailing out/ removing the solid / semi solid / liquid sludge in foul condition by using suction machine and removing/ disposing the waste outside the MD land including refixing the cover properly after washing the septic tank with clean water and bleaching powder complete all as specified and directed. |
| 21 | M&L for removal of blockage/waste and cleaning gully traps and Nahani traps of any description and size for smooth flow all as directed. |
| 22 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking up/ laying sewer line and getting out in Hard /Dense soil all as specified and directed. |
| 23 | Excavation in trenches exceeding 1.5m wide and not exceeding 3.0m in depth for taking up/ laying sewer line and getting out in Hard /Dense soil all as specified and directed. |
| 24 | Excavation over areas exceeding 10 Sqm in plan area and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed |
| 25 | Returning, filling in using excavated soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick all as specified & directed. |
| 26 | Removing of excavated surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point |
| 27 | Demolition and breaking up drain pipes 100mm dia (Salt Glazed stoneware, reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris outside the MD land complete all as specified & directed. Note for item no 27 to 29: Excavation and earth work will be measured and paid separately. |
| 28 | Description all as per item No. 27 above but drain pipe of dia 150/160 mm dia. |
| 29 | Description all as per item No. 27 here in before but drain pipe of dia 180/250 mm dia. |
| 30 | M&L for DWCPE (SN8) 180 (OD)/163(ID) mm diameter pipes laid on 150 mm thick bed 0.70 to 1.65 Rm length with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame includes all items and activities to execute and make sewer line functional. |
| 31 | M&L for Double Wall Corrugated Pipes of 150mm dia, HDPE, for replacement of GI, UV resistant -proof light weight durable, sewerage and water Purposes complete all as specified and directed. |
| 32 | M&L for Double Wall Corrugated Pipes of 200mm dia, HDPE for replacement of GI, UV resistant -proof light weight durable, sewerage and water Purposes complete all as specified and directed. |
| 33 | M&L for Double Wall Corrugated Pipes of 250mm dia, HDPE, for replacement of GI, UV resistant -proof light weight durable, sewerage and water Purposes complete all as specified and directed. |
| 34 | M&L for Salt Glazed Stoneware pipes grade 'A', of size 100mm bore, laid in trenches and jointed and testing complete all as specified and directed. |
| 35 | Description all as per item No. 34 herein before but size of 150mm bore. |
| 36 | M&L for 250mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars and testing complete all as specified and directed. |
| 37 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for bed to drain pipe of size 100mm bore including packing under and haunching against the sides of pipes after they are laid and tested all as specified and directed. |
| 38 | Description all as per item No. 37 above but bed to drain pipe of size 150mm bore. |
| 39 | Description all as per item No. 37 herein before but bed to drain pipe of size 250mm bore. |
| 40 | Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 41 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls |
| 42 | S & F 110mm dia bore PVC bends . |
| 43 | Dismantling of 100 mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out all as specified by Engr-in-Charge |
| 44 | S&F Cast iron soil, waste and vent sand cast pipes, 100mm dia bore, in any length with or without ears with cement joints, fixed to walls |
| 45 | S&F Cast iron bends 100mm dia bore (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 46 | S&F in repair for 75mm dia cast iron Nahani trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate complete and as directed. |
| 47 | S&F in repairs 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed. |
| 48 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement joints all as specified |
| 49 | Dismantling posts or struts including GI barbed wire (wood, steel or RCC) from concrete/masonry any section including taking out embedded portion and making good disturbed area as all respects complete |
| 50 | Dismantling of wrought iron or mild steel work of any description all as specified and directed. |
| 51 | Excavation in post holes (or similar holes) as in hard / dense soil each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm as specified and directed. |
| 52 | M&L for plain cement concrete 1:3: 6 type C2 40 mm graded stone aggregate as in foundations, filling and mass concrete as specified and directed. |
| 53 | M&L for M S Angle iron, flat iron, hand rails, half round or other steel section or posts and struts in fencing drilled and countersunk for balusters running bars, nosing to steps including embedding in concrete and screwing etc. flat iron to angle iron post including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe 410-0 or Fe 310-0 complete all as directed and specified. |
| 54 | M&L for Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping columns, hookingends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 55 | M&L for Galvanized, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as directed and specified. |
| 56 | Fixing only chain link fencing of 4mm dia galvanised steel wire, 100 x 100mm mesh, made up into mattresses or cages, lapped wired and laid / fixed in position, including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and directed. |
| 57 | Supply only chain link 4mm dia galvanised steel wire, 100x100mm mesh, made up into mattresses or cages, lapped wired and laid / fixed in position, complete as specified and directed. |
| 58 | Mild Steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm long but not exceeding 15 cm long , 11 to 15mm dia of neck as specified and directed. |
| 59 | M&L for two coats of synthetic enamel paint to steel surface by mechanical spray over a coat of red oxide primer including preparation of new surface over 10cm width or girth complete as specified and directed. |
| 60 | M&L for two coats of synthetic enamel paint to steel surface by mechanical spray over a coat of red oxide primer including preparation of new surface of any description not other wise described not exceeding 10 cm width or girth complete as specified and directed. |
| 61 | M&L for punched tape 0.5mm thick & 600 mm dia concertina coil, 125 to 127 clips per 6m length and 01 RM concertina coil using 10 to 15 RM single wire etc including dismantling & removing of existing coil complete all as specified and directed. |
| 62 | Taking down of cement plaster from wall surface of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed. |
| 63 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surface even & smooth without using extra cement all as specified and directed. |
| 64 | M&L for preparation of new plastered surface of walls and applying 3 coats of white wash all as specified and directed. |
| 65 | Demolition of RCC of any description and any position not otherwise specified and removing debris outside MD land. |
| 66 | M&L for pre-cast reinforced cement concrete 1:2:4, type B¬1 using 20 mm graded stone aggregate as in cover slabs (for manholes etc) shelves and similar articles with plain faces and set in cement mortar 1:6 including necessary form work complete all as specified and directed. Note: Reinforcement shall be measured and paid separately. |
| 67 | S&F in repairs, vitreous China wash hand basin, white flat back size 550 mm x 400 mm including brackets including pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe,15mm dia PVC connection pipe complete all as specified and as directed. |
| 68 | S&F in repairs, Vitreous China Squatting Pan \\"Orissa pattern\\" size 580 mmx440 mm white with integral foot rest etc. (excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed. |
| 69 | S&F in repairs, vitreous China wash down water closet (pedestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti siphonage pipe, trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed |
| 70 | S&F in repairs, vitreous China bowl, urinal flat back, size of 465X 355 X 265 mm white ( minimum) with grating and union for discharge pipe, 15mm dia PVC connection pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement etc. complete all as specified and as directed. |
| 71 | S&F in repairs,10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets, 15mm dia PVC connection pipe etc complete all as specified and as directed. |
| 72 | S&F in repair CP Health faucet with spring pipe as specified. |
| 73 | Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for and removing all the rubbish all as specified and directed |
| 74 | S&F On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for capacity of 10 users, including disconnecting the existing line from old unserviceable septic tank and connecting to the new septic tank. |
| 75 | S&F On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for capacity of 20 users, including disconnecting the existing line from old unserviceable septic tank and connecting to the new septic tank. |
| 76 | M&L for Soakage well excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top lid of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM 1:6, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size dia (1.80 M x 3.0 mtr effective depth), including disconnecting the existing line from old unserviceable soakage well and connecting to the new soakage well. |
| 77 | M&L for Soakage well excavation dia 1.80 M x 4.5 mtr effective depth, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top lid of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM 1:6, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats, including disconnecting the existing line from old unserviceable soakage well and connecting to the new soakage well. |
| 78 | Note for Item No 1 to 77: All sewage-related works under this contract shall be executed only by mechanical means. Manual cleaning/desludging/entry into sewers, manholes, septic tanks or soakage wells is strictly prohibited. Please Enable Macros to View BoQ information |