| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out complete all as specified and directed. |
| 2 | M & L for Plain cement concrete (1:2:4) type B-2 using 40 mm aggraded stone agg as in foundation filling and mass concrete complete all as specified and directed. |
| 3 | Manufacturing, supplying and fixing retro reflective Overhead informatory road signage and boards, made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTMD- 4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).complete all as specified and directed. |
| 4 | S& F stainless steel tubular pipes, Flats of stainless steel, Ornamental section like globe, pipe caps, (Min 18 gauge) of Gr 304 as in signboard poles, ficing frame etc complete all as specified and as directed. |
| 5 | S&F Italian letters of height 450mm and 60mm thickness with LED dotted lights, fixed with SS screw on ACP cladding and providing polished plain acrylic sheet having thickness of 2mm over the letters complete all as specified and as directed. |
| 6 | S&F aluminium composite panel of 4mm thick exterior grade in wall / column / ceiling with combination of aluminium skin material of 0.25mm thick (two or more metallic coloured coating sheet as directed) aluminium sheet of alloy grade 1100-H14 cover material, coated on external side with PVDF coating containing 70% resins for anti-fungal and anti bacterial properties and the center core shall be with natural polyethelene (HDPE) bonded to the aluminium skin on both side over aluminium frame of section 50 mm x 37 mm x 1.6 mm (16 gauge) fixed on the wall/ Ceiling. Cladding panel to be fixed with rawl plug and SS screw all as approved on walls and roof including necessary accessories, complete all as per manufacturer's instructions and as directed. |
| 7 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directred. |
| 8 | Supply and fixing GI bracket for street light made out of 40mm dia GI pipe medium grade 1.5 mtr length bend in shape as required complete with MS flat iron clamp,nuts and bolts, making holes in pole & bracket for cable including one coat red oxide two coat of synthetic enamal paint as existing colour all as directed and specified and as directed. |
| 9 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.5 metre in depth for laying cables/ GI tubing and getting out complete all as specified as directed. |
| 10 | M&L for sand filling in trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and directred. |
| 11 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-2. flat size 250 mm x 150 mm x 40 mm thick, concrete grade M-20 minimum complete all as specified and directred. |
| 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as directed. |
| 13 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed. |
| 14 | Material and labour for PCC for coping any size/ type for poles and road cutting whereever necessary, 1:3:6 type C-1 (Using 20mm graded stone aggregate) including dismantling old existing any size complete all as specified and as directed. |
| 15 | Supply and lay pipe galvanised iron tubing light grade of 80 mm dia in trenches/under road or floor/on wall / near pole/panel etc all as per site requirement complete all as specified and directed. |
| 16 | Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 16 sqmm 4 core, connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel / Street light boxes all as per site requirement, testing complete all as specified and directed. |
| 17 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core solid conductor nominal cross section in service connection complete all as specified and directed. |
| 18 | PCC for coping for Light pole, road cutting etc whereever necessary 1:3:6 type C-1 (20 mm graded aggregate) complete all as specified and directed. |
| 19 | M&L for tubes light grade galvanised iron pipes of 40 mm sizes with all fittings and fixed under road / culvert/cable protection complete all as specified and directed. |
| 20 | Supply and fix Solar street light fitting of LED 60 watt with 2 days backup IP 65/66 protection on existing pole with complete all as specified and directed. Make: Bajaj, Model: Falcon Plus 60W or its equivalent. |
| 21 | M&L for surface mounting maxi rex 4QTB with IP 53 box Timer switch including Contactor 16 Amp 24 volt and Thermal overload relay trip class 10 amp complete to fix in existing panel inside the 4 substation, cutting drilling and necessary cable termination complete all as specified and directred. Please Enable Macros to View BoQ information |
| 22 | M&L for surface mounting maxi rex 4QTB with IP 53 box Timer switch including Contactor 16 Amp 24 volt and Thermal overload relay trip class 10 amp complete to fix in existing panel inside the 4 substation, cutting drilling and necessary cable termination complete all as specified and directred. Please Enable Macros to View BoQ information |