| 1 | M&L for Second class hard-wood clean sawn in timber framed work scantlings fixed to walls with screws etc, complete all as specified and as directed. |
| 2 | M&L for 2nd class Hardwood Boarding 15mm thick supplied & fixed with screws on timber frame work (except flooring and skirting) planed one side and edges tongued and grooved or rebated complete all as specified and as directed. |
| 3 | M&L for prerparation of new or previosuly untreated surfaces of wood including painting with two coats (one under coat and one finishing coat with synthetic varnish) of varnishing over one staining coat with oil and one filler coat with thin varnish or lacquer or shellac varnish complete all as specified and as directed. |
| 4 | M&L for Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and as directed. |
| 5 | Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches,sockets, ceiling roses and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as specified and as directed. |
| 6 | M&L for modular switch piano, flush type, single pole, one way 6 Amps 240V complete all as specified and as directed. |
| 7 | M&L for modular socket outlet 6 Amps, multipurpose, 2/3 pin piano flush, complete all as specified and as directed. |
| 8 | M&L for modular socket outlet 15/16 Amps, multipurpose, 5 pin piano flush, complete all as specified and as directed. |
| 9 | M&L for modular ceiling fan regulator electronic step type complete all as specified and as directed. |
| 10 | M&L for Modular metal flush box 4 module complete all as specified and as directed. |
| 11 | M&L for Modular metal flush box 8 module complete all as specified and as directed. |
| 12 | M&L for Modular white cover plate with frame 4 module complete all as specified and as directed. |
| 13 | M&L for Modular white cover plate with frame 8 module complete all as specified and as directed. |
| 14 | Removing spilt type AC indoor unit from the room including disconnecting from the outdoor unit and store in a suitable place till noise reduction wooden paneling work is completed and the same is to be refixed including charging of R32 gas and plug top complete all as specified and as directed. |
| 15 | M&L for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp Capacity complete all as specified and as directed. |
| 16 | M&L for sub main wiring for A/C using two single core PVC insulated cable 6 sqmm copper conductor multi stranded insulated cable using and earth wire and drawing through and including PVC casing capping of suitable size and connecting terminal ends including provision of 6 sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly complete all as specified and as directed.Note: 3runs of cable and one run of PVC caping and caping shall be measured as one unit. |
| 17 | Supply and install hi wall split type air conditioner units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum BEE 5 star rating and EER 3.2 of capacity 1.5 TR including providing wall stand for fixing outdoor unit and providing copper pipe upto 6 RM complete all as specified and as directed. |
| 18 | S&F wall mounted type voltage stabilizer for automatic operation naturally air cooled indoor type 4 KVA capacity single phase- 220 Volts 50 HZ AC supply for voltage correction up to 170-260 Volts with accuracy of +/- 2.5% tolerance and with provision of protection relays including fixing accessories connection testing etc complete all as specified and as directed. |
| 19 | M&L for XLPE insulated heavy duty electric cables with aluminium conductor ,1100 volts grade, cross sectional area of size 2 core, but sectional area 16 sqmm complete all as specified and as directed. |
| 20 | S&F for sheet metal enclosure for DB's Double door,vertical type, single pole and neutral, 8 way including backing plate with 200 amp rated bus bar, 240 volts fixed sunk/flush to the wall complete all as specified and as directed. |
| 21 | S&F for amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole and netural with current carrying capacity 63A in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 22 | Supply and fix 240 Volts, 10KA 'C' curve miniture circuit breaker (MCB) of single pole with current carring capcity 20 Amps, in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 23 | Taking down the old US LT Panel Boards including disconnection of the all the incoming and outgoing connections complete all as specified and as directed. |
| 24 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in deep and getting it out in soft loose/soil including forming bottom surface to required level for laying pipes complete all as specified and as directed. |
| 25 | Returing filling in excavated soil including spreading, levelling, watering and well ramming in layers not exc. 25cm complete all as specified and as directed. |
| 26 | Removing excavation soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 27 | Supply, install, testing and commissioning of factory fabricated out door type Main LT panel of size (2.0m x 1.5m x 0.6m) made out of 3.15 mm thick CRCA sheet and angle iron of size (40 x 40 x 5 mm) floor mounted type with Aluminium bus bar of capacity 1000 Amp- 4 Nos including two coats of synthetic enamel paint over a coat of red oxide, including voltmeter, ammeter, with necessary CTs & PTs, selector switches, phase indication lamps for three phase system, control panel & power panel wiring, cable alleys at both side, confirming to IS:8623, IEC:60439 & CPRI Approved, protection class IP65 including necessary grouting and PCC complete with legs 30cm in ground in PCC and 50cm above ground including grouting with PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including connecting cables with cable glands lugs etc and consisting of the following accessories :- (a) MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 50 KA (incomming)- 01 No(b) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps 36 KA- 02 Nos(c) MCCB 4 Pole, 415 V, Thermal Magnetic Release, 125 Amps 10 KA- 01 No(d) MCCB 4 Pole, 415 V, Thermal Magnetic Release, 100 Amps 10 KA- 01 No(e) MCCB 4 Pole, 415 V, Thermal Magnetic Release, 63 Amps 10 KA- 01 No(f) MCCB SPN C-Curve 32 Amp, 240 V- 01 No(g)Spare -02 Noscomplete all as specified and as directed. |
| 28 | Supply, install, testing and commissioning of factory fabricated out door type Main LT panel of size (1.5m x 1.2m x 0.6m) made out of 3.15mm thick CRCA sheet and angle iron of size (40 x 40 x 5 mm) floor mounted type with Aluminium bus bar of capacity 300 Amp- 4 Nos including two coats of synthetic enamel paint over a coat of red oxide, including voltmeter, ammeter, with necessary CTs & PTs, selector switches, phase indication lamps for three phase system, control panel & power panel wiring, cable alleys at both side, confirming to IS:8623, IEC:60439 & CPRI Approved, protection class IP65 including necessary grouting and PCC complete with legs 30cm in ground in PCC and 50cm above ground including grouting with PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including connecting cables with cable glands lugs etc and consisting of the following accessories :- (a) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA (incomming)- 01 No(c) MCCB 4 Pole, 415 V, Thermal Magnetic Release, 63 Amps 10 KA- 05 Nos(c) MCCB 4 Pole, 415 V, Thermal Magnetic Release, 32 Amps 10 KA- 01 No(d) MCCB SPN C-Curve 32 Amp, 240 V- 01 No(e)Spare -02 Noscomplete all as specified and as directed. |
| 29 | Supply, install, testing and commissioning of factory fabricated out door type Main LT panel of size (1.5m x 1.2m x 0.6m) made out of 3.15 mm thick CRCA sheet and angle iron of size (40 x 40 x 5 mm) floor mounted type with Aluminium bus bar of capacity 400 Amp- 4 Nos including two coats of synthetic enamel paint over a coat of red oxide, including voltmeter, ammeter, with necessary CTs & PTs, selector switches, phase indication lamps for three phase system, control panel & power panel wiring, cable alleys at both side, confirming to IS:8623, IEC:60439 & CPRI Approved, protection class IP65 including necessary grouting and PCC complete with legs 30cm in ground in PCC and 50cm above ground including grouting with PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including connecting cables with cable glands lugs etc and consisting of the following accessories :- (a) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps 36 KA (incomming)- 01 No(b) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA (incomming)- 01 No(c) MCCB 4 Pole, 415 V, Thermal Magnetic Release, 63 Amps 10 KA- 02 Nos(d) MCCB 4 Pole, 415 V, Thermal Magnetic Release, 32 Amps 10 KA- 01 No(e) MCCB SPN C-Curve 16 Amp, 240 V- 03 Nos(f) MCCB SPN C-Curve 10 Amp, 240 V- 01 No(g) ON load change over switch 160 Amps capacity-01 Nocomplete all as specified and as directed. |
| 30 | Supply, install, testing and commissioning of factory fabricated out door type Main LT panel of size (1.0m x 1.0m x 0.6m) made out of 3.15 mm thick CRCA sheet and angle iron of size (40 x 40 x 5 mm) floor mounted type with Aluminium bus bar of capacity 125 Amp- 4 Nos including two coats of synthetic enamel paint over a coat of red oxide, including voltmeter, ammeter, with necessary CTs & PTs, selector switches, phase indication lamps for three phase system, control panel & power panel wiring, cable alleys at both side, confirming to IS:8623, IEC:60439 & CPRI Approved, protection class IP65 including necessary grouting and PCC complete with legs 30cm in ground in PCC and 50cm above ground including grouting with PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including connecting cables with cable glands lugs etc and consisting of the following accessories :- (a) MCCB 3 Pole, 415 V, Thermal Magnetic Release, 63 Amps 16 KA- 01 No(b) MCB 4 Pole, 415 V, C-Curve, 32 Amps 10 KA- 01 No(c) MCB SPN, 240 V, C-Curve, 32 Amps 10 KA- 02 Nos(d) DOL Starter for single Phase 2.0 HP Pump,16A-01 No(e) DOL Starter for 3 Phase 7.5 HP Pump,with over load relay range 10-16A- 01 Nocomplete all as specified and as directed. |
| 31 | Taking down and re-laying of the existing UG Cable PVC/ XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 to 300 sq mm 2/3, 5/4 core complete all as specified and as directed.Note :- The UG Cables shall be terminated with suitable size of aluminium thimbles at no extra cost. |
| 32 | M&L for XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of following sizes:-(a) 3.5 core 95 sqmmcomplete all as specified and as directed. |
| 33 | S&F for DWC pipe of size 110mmx95mm (outer and inner dia)for protection of LT cable of size 300/120/95 sqmm complete all as specified and as directed. |
| 34 | M&L for earthing complete with Galvanised steel earth plate electrode (60 cm x 60 cm x 6 mm) thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised strip (32 x 6 mm) connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe light grade for protection of GI strip (32 x 6 mm) and 20 mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC (1:2:4), type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n.exc. 50 mtr, provision of charcoal and salt complete all as specified and as directed. Please Enable Macros to View BoQ information |