| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground post embedded in natural ground complete all as specified and as directed. |
| 2 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement concrete and making good disturbed ground complete all as specifed and directed. |
| 3 | Excavation for post holes in any type of soil (or in similar hole ) each n.exc 0.50 Cum including dismantling PCC including disposal of surplus n.exc 50m complete all as specified and directed. |
| 4 | M&L for PCC 1:3:6 type C-2 (20mm graded crushed stone aggregate) in foundation filling and mass concrete all complete all as specified and directed. |
| 5 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 6 | Supply only PVC coated MS Chain link fencing with line wires,any type and mesh size and any type of standards and dia of wire ( as directed by Engineer-in-charge) fixed with rails, staining bolts etc including provision of binding wire including dismantling existing unserviceable fencing complete all as specified and directed.(Note: rails, staining bolts will be measured in seperate Item) |
| 7 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 8 | S&F MS bands, straps, supports or stays for rainwater, ventilating pipes, including bolts if reqd, hooks(stay), hook and pintle hinges, large hasp and staples, clamps, hold fasts, wall ties, plain angle cleats for securing purlins to wood trusses or rafters and similar small articles confirming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 9 | Demolition of brick work, stone/boulder masonry built in cement mortar complete all as specified and directed. |
| 10 | Brick work with sub class 'B' (old size) bricks, straight or curved on plan to any radius built in cement sand mortar 1:4, complete all as specified and directed. |
| 11 | All as per Ser item No. 10 above but except bricks complete all as specified and directed. |
| 12 | M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:4 complete all as specified and directed. |
| 13 | All as per Ser item No. 12 above but except Stones complete all as specified and directed. |
| 14 | Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 15 | Rendering 15mm thick in cement mortar 1:4 including water proofing compound as per manufacturer instructions on other than fair faces of brick work finished even and smooth without using extra cement, complete all as specified and directed. |
| 16 | M&L for preparation of newly plastered surface of wall applying two coat of cement base paint over a one coat of alkali resistant primer, complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 17 | M&L for preparation of new plastered/unplastered surface and finishing walls with Acrylic Smooth exterior paint of required shade as approved by GE with two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on walls over 3mm thick plaster of paris putty complete all as specified and directed.Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b) The acrylic emulsion paint work shall be carried out by using smart painting tools and techniques as specified in Particular Specifications and Contractor will have to produce necessary documents for purchase of smart painting tools or rent receipt of these tools along with bill/RAR.The bidders are requested take this aspect in consideration before quoting their rate and no claim on account of misunderstanding or otherwise shall be admissible on this account. (c) The painting is to be done in one or more shades as approved by GE. |
| 18 | Preparation of old decorated plastered or unplastered surface including cleaning by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasy spots and applying one coat of cement base paint on walls of external surfaces.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 19 | M&L for preparation of old decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasy spots and finishing walls with Acrylic Smooth exterior paint of required shade as approved by GE with two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on walls over 3mm thick plaster of paris putty complete all as specified and directed.Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b) The acrylic emulsion paint work shall be carried out by using smart painting tools and techniques as specified in Particular Specifications and Contractor will have to produce necessary documents for purchase of smart painting tools or rent receipt of these tools along with bill/RAR.The bidders are requested take this aspect in consideration before quoting their rate and no claim on account of misunderstanding or otherwise shall be admissible on this account. (c) The painting is to be done in one or more shades as approved by GE. |
| 20 | Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion complete all as specified and directed. |
| 21 | M&L Plain cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 22 | M&L Reinforced cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in foundation including raft footing, foundation beam, plinth beam, bases of columns etc basement slab under reamed piles and mass concrete complete all as specified and directed. |
| 23 | M&L Reinforced cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in beams, cantilivers, bressummers, lintels over 1.5 m span complete all as specified and directed. |
| 24 | M&L Reinforced cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 25 | M&L use and waste of formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides & soffits (if any) of foundation and plinth beams and similar work, vertical or to batter including rough finished surfaces of concrete complete all as specified and directed. |
| 26 | M&L use and waste of formwork to sides of pillars, struts, piers, columns and stanchions including rough finished surfaces of concrete, square, rectangular or polygonal in sections concrete, complete all as specified and directed. |
| 27 | M&L use and waste of form work to sides and soffits of flat, lintels etc rough finished etc complete all as specified and directed. |
| 28 | M&L for TMT bars 10mm dia & over cut to length bent to shape required including, cranking, bending spirally, hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 29 | All as per Srl item No. 28 above here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, complete all as specified and directed. |
| 30 | Plain cement mortar (1:2:4) type B-1 using 20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, formwork (straight or curved) complete all as specified and directed. |
| 31 | M&L for providing precast cement concrete (type B0 1:2:4 12.5mm graded crushed stone aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings and form work including demolition of old louvres and jallies complete all as specified and directed. |
| 32 | Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face at junction of RCC and brickwork complete all as specified and directed. |
| 33 | S&F PVC 110 mm Dia (SWR) pipes single socketed, in any length with rubber ring joints,Uses as weep hole complete all as specifed and directed. |
| 34 | S & F mild steel of grade Fe-290 (Grade E-165) in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work, complete all as specified and directed. |
| 35 | Fixing only mild steel of grade Fe-290 (Grade E-165) in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work, complete all as specified and directed. |
| 36 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 37 | Preparation new steel surfaces or iron works of any description, over 10cm in width or girth not otherwise and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 38 | Preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth, and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 39 | Dismantling of Barbed wire in fencing of any description complete all as specified and directed |
| 40 | S&F in Repair Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as complete all as specified & directed. |
| 41 | Restraining & resecuring existing barbed wire of any type incl making good staples etc any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc (each line wire to be measured separatley) complete all as specified and directed. |
| 42 | S&F in Repair Punched Tape Concertina Coil (including spike and handle) with 56 loops and dia 600mm, Max covered length 10 RM, having a core wire of high carbon spring steel of high tensile strength conforming to IS 4454/Part-I/Grade-SM, duly hot dipped galvanized with heavy zinc coating with minimum 230 gms per Sqm. The punched tape and core wire (2.5 + 0.35mm dia) shall be heavy galvanized (IS-1730) (Wire-275GSM & strip-200 GSM) conforming to IS-513 to provide protection against outdoor exposure. The punched tape shall mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of the coil. The width of strip as 19mm and spacing of blades 24.00 + 0.5 mm C/C. The weight of each coil shall be 8.50 + 5% Kgs without packing material and coil length 10 Mtr (maximum) when opened up, (Each coil should packed with bituminized hessian cloth for providing protective packing) as in fencing including fixing with special galvanised fasteners such as J clips, C clips, U clips fixed at any height on compound wall including dismantling old concertina coil wire including necessary scaffolding as required complete all as specified and directed.[Note: After stretching the coil the length of the compound wall on which it has been stretched shall be measured as straight length for payment] |
| 43 | S&F in Repair Punched Tape Concertina Coil (including spike and handle) with 56 loops and dia 900mm, Max covered length 10 RM, having a core wire of high carbon spring steel of high tensile strength conforming to IS 4454/Part-I/Grade-SM, duly hot dipped galvanized with heavy zinc coating with minimum 230 gms per Sqm. The punched tape and core wire (2.5 + 0.35mm dia) shall be heavy galvanized (IS-1730) (Wire-275GSM & strip-200 GSM) conforming to IS-513 to provide protection against outdoor exposure. The punched tape shall mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of the coil. The width of strip as 19mm and spacing of blades 24.00 + 0.5 mm C/C. The weight of each coil shall be 8.50 + 5% Kgs without packing material and coil length 10 Mtr (maximum) when opened up, (Each coil should packed with bituminized hessian cloth for providing protective packing) as in fencing including fixing with special galvanised fasteners such as J clips, C clips, U clips fixed at any height on compound wall including dismantling old concertina coil wire including necessary scaffolding as required complete all as specified and directed.[Note: After stretching the coil the length of the compound wall on which it has been stretched shall be measured as straight length for payment] |
| 44 | Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below & above GL) unreinforced complete all as specified and directed. |
| 45 | M&L for 75 mm thick PCC 1:4:8 type D-2 using 40mm graded as in sub base of floor, hard standing (40 mm graded crushed stone aggregate), finishing even and smooth without using extra cement to received tiles including necessary form work etc complete all as specified and directed. |
| 46 | M&L for sand cushioning under floor or in foundation including watering and consolidation complete all as specified and as directed. |
| 47 | M&L in repair 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and laid over and including 25mm thick grid cushion complete all as specified and directed. |
| 48 | M&L in repair 80mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-40 Gde of approved shape, size and colour conferming to IS 15658-2006 and laid over and including 25mm thick grid cushion complete all as specified and directed. |
| 49 | M & L for fixed in repair Chequered cement concrete tiles of size 30cm x 30cm x 25 mm thick (with grey cement and pigments) set, jointed and pointed in neat cement slurry in floor,laid over and incl 20mm thick cement screed base in CM 1:4, complete all as specified and directed. |
| 50 | M & L for fixed in repair Chequered cement concrete tiles of size 30cm x 30cm x 25 mm thick (with grey cement and no pigments) set, jointed and pointed in neat cement slurry in floor,laid over and incl 20mm thick cement screed base in CM 1:4, complete all as specified and directed. Please Enable Macros to View BoQ information |