| 1 | Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) of any description and removal of rubbish off from site to out side MoD land, complete all as specified & directed. |
| 2 | M & L for 50 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 50 mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed. . |
| 3 | Dismantling of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & as directed. |
| 4 | M&L for plain cement concrete mix (1:2:4 ) type B-1 (using 20 mm graded crushed stone aggregate) solid building blocks exceeding 10 cm in width ,set in cement mortar (1:6) complete all as specified and directed. |
| 5 | M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed. |
| 6 | M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 but except stone complete all as specified and directed.Note Stone retrived from item No. 03 here-in -before of BOQ. |
| 7 | M&L for extra over squarred rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing complete all as specified and directed. |
| 8 | M&L for 5 cm thick sand stone slabs as in window cills , sun-shades, chajjas, shelves, landings, cover stones, templates, etc. not exceeding 2.0m in length,punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4.complete all as specified & directed |
| 9 | Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc & removing the debris from the premises upto 500 m from the MOD land complete all as specified and directed. |
| 10 | M&L for 15 mm thick rendering in CM 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement including necessary scaffolding arrangement mix with using water proofing compound, complete all as specified and as directed. Note: WPC shall be measured and paid separately under respective item of BOQ. |
| 11 | Racking out joints/pointing to square rubble masonry Jodhpur type regular coursed built in cement mortar complete all as specified and as directed. |
| 12 | M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in cement mortar 1:3 complete all as specified and as directed. |
| 13 | M & L for preparation of newly plaster/unplastered surfaces of walls/chajjas/lintel and applying two coats of cement base paint (white or tinted) over a coat of alkali resistant primer, complete all as specified & directed. |
| 14 | M&L for prepartion of old painted of steel surface of any description , not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint (ordinary tint) any colour on old steel painted surface complete all as specified & directed. |
| 15 | M&L for precast reinforced cement concrete 1:2:4 ,type B-1 (using 20 mm graded crushed stone aggregate) as in kitchen platform, shelves ,man hole cover slab, chullah hoods, chajjas, water troughs, mangers, shelves and similar articles including necessary formwork complete all as specified and directed. Note : Reinforcement will be measured & paid seperately under respective item of BOQ. |
| 16 | Dismantling post or struts (RCC) any position,including taking out embedded portion and making good disturhed ground, post embedded in concrete, brick work, masonry etc complete all as specified & directed. .(Note- Only embedded portion of post or strut will be measured for payment) |
| 17 | Dismantling expanded metal, chain link fencing in carefully any thickness or mesh, any size or any type fixed with steel or wood fillets, if any all as directed complete all as specified & directed. |
| 18 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out & removing surplus soil material to a distance not exceeding 50 mtr & and making good surfaces in any type of hard & dense soil complete all as specified and directed. |
| 19 | M&L for mild steel \\"TMT\\" bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends & binding with & including with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 20 | Supply only Chain link MS galvanized fencing 4.0 mm dia GI wire 75 mm x 75mm /50 mm x 50 mm mesh made up to mattresses or cages lapped wired and laid in position including closing and tied with RCC posts properly complete all as specified & directed. Note: BOO will consitute by GE to determinate the weight/ sqm of chainllink fencing of avg of three rolls |
| 21 | Fixing only chain link MS galvaniced fencing including line wires any mesh size and type to any type of standards, rails straining bolts etc including provision of binding wire complete all as specified and directed. |
| 22 | S&F in repairs Galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc all as specified and Directed (each line wire to be measured) complete all as specified & directed. |
| 23 | S&F for mild steel screw bolts 11mm to 16 mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 10 cm but not exceeding 15cm long complete all as specified and as directed. |
| 24 | M&L for 75mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc.,complete all as specified and directed |
| 25 | M & L for chequered cement concrete tiles(laquer coated) 30cm x 30cm x 25 mm thick / 20cm x 20cm x 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry as in floors/ path etc over and including 15mm thick in cement mortar 1:6 as in screed bed or bedding layer including dismantling of existing tile complete all as specified and as directed. |
| 26 | M&L for providing and laying (rubberised interlocking paver) 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;including dismantling of existing tile/ paver complete all as specified and as directed. |
| 27 | Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified & directed. |
| 28 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified & directed. |
| 29 | S&F of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to (Fe 410-W grade E-250) quality A.complete all as specified and as directed. |
| 30 | M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 31 | Dismantling of asbestos cement/ steel sheeting (plain, corrugated or semi corrugated etc., ) as in roof coverings complete all as specified and as directed . |
| 32 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 33 | S&F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 Gde-E-165 complete all as specified & directed. |
| 34 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching /copings, benching to drain including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed |
| 35 | M&L for providing precast cement concrete 1:2:4 type B-0 (12.5mm graded crushed stone aggregate) set in CM 1:4 for louvres and jallies, cement grill any type model of zafri 35/40 mm thick (measured solid), including all mould- ings complete all as specified & directed by Engineer-in-charge. |
| 36 | M&L providing precast concrete posts 1:2:4 type B-0 (12.5mm graded crushed stone aggregate)( size 150 mm x150mm) & 75-100 cm height as in RCC jali post setting in CM 1:6 complete with & including required reinforced complete all as specified & directed by Engineer-in-charge. |
| 37 | S & F in repairs retro reflective informatory sign board 60 cm x 90 cm as per IRC 67 made out of high intensity reflective grade sheeting fixed over aliminium sheeting 1.5mm framed with 25 mm stainless steel square tube(GradeSS 304) supported on stainless steel (GradeSS 304) 40mm dia pipe 3.0m length including 0.5m embeded in PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed. Note :(i) The size of post hole for embedded in PCC BLOCK of post shall be 45 x 45 x 60cm with excavation & earth work.. (ii) The stainless steel shall be of SS 304 Gde. |
| 38 | NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of \\"Credit\\" from the Total quoted amount Please Enable Macros to View BoQ information |