| 1 | 1 Part I- Electrification &Providing Submersible Pumpset-( Materials used for the work shall be as per list of materials approved by the District level technical committees and attached as separate document) |
| 2 | OD29284/2026-2027:Supply, conveyance, installation, testing and commissioning of 2 HP , Open well Submersible motor pump set of pipe size 50 mm working suitable for single phase, 240V, 50 Hz AC supply and giving connections and trail run on full load. .( Deccan sub-Pump 2HP ER40H-VR/40-2 HP DOL ST or equivalent make |
| 3 | OD29286/2026-2027:Supply and providing BCH make DOL Starter with protection against overload, single phasing, phase reversal & amp; severe unbalanced voltages conditions, in accordance with latest IS/IEC 60947-4-1specifications suitable for 2 HP Submersible motor pump set complete duly internally connected |
| 4 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 5 | OD29288/2026-2027:Supply and providing Ashirwad UPVC adapter set 50mm DC CI |
| 6 | OD29285/2026-2027:Supply and fitting HDPE pipe PN6 PE 63 , 50mm shartec /equivalent make including all accessories etc as required. |
| 7 | OD29290/2026-2027:Supply conveyance and providing nylon MAXIMA LG14MMrope for hanging sub-pump set |
| 8 | OD29289/2026-2027:Supply and fixing CLAMP SET CI 50MM for erection of pump set |
| 9 | OD29299/2026-2027:Supply and fixing 50mmx 12" GI Barrel nipple |
| 10 | OD29300/2026-2027: Supply and providing rubber packing as required |
| 11 | OD29301/2026-2027:Supply and fitting 50 mm Non Return valve using required bolt and nut and flange etc |
| 12 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 13 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 14 | 2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 15 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 16 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 17 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 18 | OD29303/2026-2027:Supply and fitting 32A HRC fuse base with HRC fuse link |
| 19 | OD29304/2026-2027:Supply and installation of Hot press moulded SMC single phase meter box of size 350x250x150mm sintex make GS-MB-3425 or equivalent |
| 20 | OD29302/2026-2027:Supply and fitting 32A 2 way neutral link mounted on DMC/SMC base Please Enable Macros to View BoQ information |