| 1 | 90 od |
| 2 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point |
| 3 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points |
| 4 | OD231038/2025-2026:Supply & fitting K.lite .code No. 4983 27 W. LED .TR. light house midi post top lantern or it's equivalent make on the existing post & giving connection as required. |
| 5 | 90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe |
| 6 | OD202870/2025-2026:Supply,conveyance,installation, testing & commisssioning of 20W LED flood light out put greater than 105 lumen/W 4000-6000 k with IP 66 protetion chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load,internal surge protection up to 8 KV and Alu. pressure die -cast powder coated housing acrylic cover complete with THD less thaaaaaaaaan 10% ,power factor greater than 0.98.ROHS compliant, duly wired up for use on 230 v, AC supply.Driver compartment should be separatly ccessible for maintenance(LM 79&80 certificates from NABL accreted. Third party lab to be produced mentioning chip manufacture. |
| 7 | 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 8 | OD231035/2025-2026:Supply & fitting Hensel make (cat No. KFo4o4 G with terminal connectors ) out door connection box with terminal connectors size 104 x 104 x 70 mm. as required. |
| 9 | OD230913/2025-2026:Supply & clamping LED strip out door type 12w/mtr.length on existing 150mmdia/200mm dia GI pipe using suitable size GI saddles with steel screws etc. in position as required. Philips/crompton/Oasis/equivalent. |
| 10 | OD230970/2025-2026:Supply & fitting LED strip connector / adapter in position as required. |
| 11 | OD231033/2025-2026:Supply & fitting 4 channal POE switch in position as required. |
| 12 | OD231034/2025-2026:Supply & fitting 4 channal NVR in position as required. |
| 13 | OD231303/2025-2026:Supply & fitting sintex box GB-JB.-3425(350x250x150) on the existing post top ,using suitable size clamps,nut & bolts etc. as required.( for fixing 4 channal NVR, 4 channal POE switch etc.) |
| 14 | OD231304/2025-2026:Supply & fitting camera weather proof housing as required. |
| 15 | OD231305/2025-2026:Supply & fixing PVC fixing box for camera. |
| 16 | OD231306/2025-2026:Supply & fixing HIKVISION 4 megapixel digital IP full HD with 4mm fixed lens, true WDR , HLC ,BLC, IR , bullet night vision net work camera. |
| 17 | OD231307/2025-2026:Supply & fixing surveillance hard disk 500 GB as required. |
| 18 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 19 | OD202853/2025-2026:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel . |
| 20 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 21 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) |
| 22 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 23 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 24 | 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 25 | 15.4.1:Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required1 output per phase and suitable for single phase supply |
| 26 | OD202855/2025-2026:Supply & providing single phase 25A power contactor fitted in position as required. |
| 27 | OD202891/2025-2026:supply & fitting DIN bar/ channel suitable for fixing SPMCB,TPMCB,RCCB etc. fitted in the existing meter board. |
| 28 | OD203340/2025-2026:Supply & fixing sintex or it's equivalent make junction box in position as required. (model GSJB-1414.) size 140x140x95mm |
| 29 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 30 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 31 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 32 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 33 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 34 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 35 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 36 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 37 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 38 | OD202852/2025-2026:Supply & fixing 16A 3 way bakelite connector in position s required |
| 39 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 40 | 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm |
| 41 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 42 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 43 | OD202851/2025-2026:Supply & providing 25x6 mm brass bolt , nut with washers on the existing MS box/earth bus etc. as required including drilling holes as required. |
| 44 | OD202888/2025-2026:S&P 12x3mm brass bolt & nut with wshers |
| 45 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 46 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 47 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 48 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 49 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 50 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 51 | OD231130/2025-2026:supply & fitting sintex box with hinged door on existing pedastial angle iron stand with suitable size GI unt & bolt with washers (GS-MB-7450, 700x480x200) as required. |
| 52 | OD202843/2025-2026:Supply & providing 32A HRC fuse base with HRC fuse link. |
| 53 | OD202848/2025-2026:Supply & providing 32A ,2 way NL on existing meter box |
| 54 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 55 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 56 | OD202882/2025-2026:Supply & laying ,clamping ,jointing of DWC pipe 40/32 mm in the existing metal portion as required for protection of UG cable. |
| 57 | OD202844/2025-2026:Supply & fabricating suitable size support made out of 35x35x5 mm or nearest size angle iron as required including painting as required. |
| 58 | OD202846/2025-2026:Earthing with 40 mm dia. medium class GI earth pipe 2.5 Mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm GI reducer at top, test joint using 2 nos ,25x3 mm GI strip minimum size 25CM suitably shaped & tightly clamped to the pipe using 25x6 mm steel bolt & nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping & bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal & salt as required shall be filled at 30 CM dia .around the earth electrode) |
| 59 | 90.16.2.2:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class) |
| 60 | OD230985/2025-2026:Supply & fixing fiber make motor cover suitable for 1/2 HP motor pump in position as required. |
| 61 | OD230986/2025-2026:Supply & installation of 0.5 HP centrifugal 1 phase motor pump set v- guard model No. VSPA H-80 with discharge of 1900 to 750 lpm at a head of 6 m to 14 m or equivalent Kirlosker make in position as required. |
| 62 | OD231616/2025-2026:Supply & fitting angle iron/ flat iron make motor stand fitted on wall in position as required. |
| 63 | OD202889/2025-2026:Painting letters/figures of the following sizes with enamel paint as identification mark to SB,DB,panel board etc. as required. 2.5x4 cm. size |
| 64 | OD202854/2025-2026:KSEB connection charges & Concrete support post. actual amount reimbursed producing original bills. Please Enable Macros to View BoQ information |