| 1 | Erection of suspension clamp for LT ABC of any size |
| 2 | Providing one Earth using GI earth pipe of size 38.1mmdia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at a minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in ordinary soil & backfilling. |
| 3 | Additional rate for excavation of one Earth Pit (2.5m depth) in Hard Laterite. |
| 4 | Re-Tensioning one span 11kV line including replacing pin insulators, pin binding, jumpering, replacinginsulators cross arms disc, tightening stay, cutting treebranches etc. wherever necessary, including conveyance of all materials complete. |
| 5 | Labour charges for loading HT PSC pole from thestacking place and unloading the same at work site (transportation by any vehicle). |
| 6 | Labour charges for loading HT A type pole from thestacking place and unloading the same at work site(transportation by any vehicle). |
| 7 | Labour charges for loading LT PSC pole from thestacking place and unloading the same at work site(transportation by any vehicle). |
| 8 | Transporting poles by hired vehicle to a distance upto5km and carrying upto 4 numbers of poles excludingloading& unloading charges. |
| 9 | Transferring LT single phase 2/3 wire OH line to newlyerected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete. |
| 10 | Transferring LT three phase 4/5 wire OH line to newlyerected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete. |
| 11 | Dismantling (without damage) one Channel crossarm from existing DP structure and bringing backto section store. |
| 12 | Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole including conveyance ofmaterials. |
| 13 | Fitting one Additional 2.4m/3m Channel cross arm(100x50x6mm), in existing 11kV DP includingconveyance of materials. |
| 14 | Providing Stay for LT poles including digging & backfilling pit in ordinary soil. |
| 15 | Additional rate for excavation of one Pit for LT Pole/LT Stay in Hard Laterite. |
| 16 | Additional rate for refitting/redoing one Shackle Set, including reshacling one span, while renewing anytype of LT pole. |
| 17 | Dismantling (without damage) one km LT three phase 4 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly. |
| 18 | Dismantling (without damage) one km LT additional conductor line by dismantling cross arms, insulators and stacking the conductors in rolls properly. |
| 19 | Disconnecting and lowering down the single phase WPservice connection with guy wire from the OH line and reconnecting the same after completing the line work. |
| 20 | Disconnecting and lowering down the three phase WPservice connection with guy wire from the OH line andreconnecting the same after completing the line work. |
| 21 | Dismantling one ordinary street light/CFL/LED fittingfrom existing pole and refitting the same on newlyerected pole including disconnecting and reconnecting wires. |
| 22 | Fiting One No MVT on existing cross arm excludingtermination work (for One phase) of any rating for 11kV AB Cable |
| 23 | Dismantling one suspension clamp from 11 KV ABC |
| 24 | Erection of suspension clamp for 11KV ABC of any size |
| 25 | Dismantling one Anchor clamp /dead end clamp from11 KV ABC |
| 26 | Erection of Anchor clamp / dead end clamp for 11kVABC of any size |
| 27 | Dismantling of Anchor clamp / dead end clamp forLT AB cable |
| 28 | Erection of Anchor clamp / dead end clamp for LT ABCof any size |
| 29 | Transporting LT ABC by hired vehicle to a distance up to 5 km and carring up to 2 drum including loading and un loading using crane |
| 30 | Stringing of 1.1 kV Aerial bunched cable of size 3 x 70+ 1 x 16+1x 50 sqmm with bare/insulated Messengerthrough existing poles |
| 31 | Fitting of one No. pole top service connection box ofstandard size (up to 4 way) using ss strap/B&N ofsuitable size in to the PSC/A poles at the standard height excluding giving connections |
| 32 | Installation of Insulation piercing connector for mainto service line main :50-150 sqmm, Tap : 4-35 sqmm |
| 33 | Installation of Insulation piercing connector for mainto service line main :25-95 sqmm, Tap : 25-95 sqmm |
| 34 | Installing One No. Insulation piercing connector of sizeMain :16 to 95 ,Tap:1.5 to 16 Sq.mm |
| 35 | Dismantling one damaged 11kV A type pole afterdisconnecting stays, strut etc. attached thereon and stacking the same. |
| 36 | Dismantling transformer station with transformererected in DP structure by dismantling HT Double PoleStructure using PSC pole after disconnecting stay wires, 10 channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipments, CTs, Distribution Box, statutory display boards etc. but excluding the rate of dismantling transformer, earthing, stay sets & fencing. |
| 37 | Dismantling one Transformer (upto and including 160kVA) from existing structure and loading to any vehicle directly, including disconnecting HT/LT/Earthconnections. |
| 38 | Fitting 6 channel cross arms, AB switch, DO fuse, Stationclass LA, HT & LT connections upto OH lines, etc. on existing DP structure, Fixing distribution box/provision for one set (3No.) of LT fuses, drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing & mounting of Transformer on poles. |
| 39 | Providing one Earth using GI earth pipe of size 38.1mmdia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at standard distance (1.5m) away fromthe pole/structure in ordinary soil & backfilling the pit with 15cm alternate layer of charcoal, salt and sand up to 90cm from the bottom. including the cost of 20kgsalt, 25kg charcoal, excluding supply of earth pipe. |
| 40 | Erecting one 160kVA Transformer to existing DP and giving connections, including loading from TMR/SRS/other stacking place & unloading at site butexcluding cost for transporting transformer. |
| 41 | Providing Transformer fencing to a height of 1.8 mabove ground level using MS Angle frames of size ISA50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizondal brasing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with syntheticenamel paint two coats over one coat of iron primer etccomplete, incl cost of transportation |
| 42 | Cleaning and levelling of transformer yard/RMU,spreading 40 mm broken stone in yard for a thicknessof 10 cm above bed of 10 cm thick 6 mm broken stone,after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc. |
| 43 | Dismantling one damaged 11kV PSC/RCC pole afterdisconnecting stays, strut etc. attached thereon and stacking the same. |
| 44 | Dismantling (without damage) one 11kV PSC/RCCpole after disconnecting stays, strut etc. attachedthereon and stacking the same. |
| 45 | Dismantling one damaged LT PSC/RCC pole afterdisconnecting stays, strut etc. attached thereon and stacking the same. |
| 46 | Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same. |
| 47 | Dismantling (without damage) one HT PSC/RCCStrut pole including removal of clamps and stacking. |
| 48 | Fitting and erecting one HT PSC Single Pole in position,including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficientlength of GI earthing leads from F clamp through Vcross arm to the ground for earthing (excluding provisionof earthing). |
| 49 | Fitting and erecting one HT A type Single Pole in position, including fitting cross arm, digging and backfilling pit in ordinary soil (as per standards), drawingsufficient length of GI earthing leads from F clampthrough V cross arm to the ground for earthing(excluding provision of earthing). |
| 50 | Fitting and providing one Strut using HT PSC poleincluding digging and back filling pit in ordinary soil. |
| 51 | Erecting one LT PSC Pole in position including digging &back filling pit in ordinary soil. |
| 52 | Fitting and providing one HT Stay for 11kV pole, including digging and back filling pit in ordinary soil. |
| 53 | Fitting and erecting one HT Double Pole Structure usingA type pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing). |
| 54 | Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing. |
| 55 | Dismantling one damaged AB switch from existingstructure and bringing back to section store. |
| 56 | Additional rate for refitting/redoing one Disc setwhile renewing any type of 11kV cut pole. |
| 57 | Additional rate for excavation of Pit for A type pole in Hard Laterite. |
| 58 | Additional rate for excavation of one Pit for HTPole/HT Stay in Hard Laterite. |
| 59 | Providing concrete muffing of size 0.45x0. 45x1.5m(0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides. Please Enable Macros to View BoQ information |