| 1 | Civil road and Drain work |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR 2023/15.2.1 |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar DSR 2023/15.7.4 |
| 4 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.DSR 2023/15.6 |
| 5 | Excavation in foundation in ordinary Soil ( Loam clay or sand ) including filling lift upto 1.5metre (5fts.) and lead upto 30.0 m (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in- charge upto a distance of 30 M. (100 fts.) from the foundation trenches.SOR2022/251 |
| 6 | Earthwork in filling in cartage upto 8 KmSR |
| 7 | Construction of granular sub-base by providing close graded Material, spreading in uniform layers with motor grader on prepared surface,mixing by mix in place method with front end loder at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.SR |
| 8 | Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.SOR2022/ 281 |
| 9 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixerDSR 2023/16.43.2 |
| 10 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)DSR 2023/16.45 |
| 11 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.Using grade ‘A’ sealing compound conforming to IS: 1834.DSR 2023/16.46.1 |
| 12 | Mild Steel or iron in plain work such as in reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastages and over lapping and hookes.SOR2022/504 |
| 13 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth levelConcrete of m25 grade with minimum cement content of 330 kg /cumDSR 2023/5.33.1.1 |
| 14 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymerDSR 2023/26.31.1 |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concreteDSR 2023/5.9.1 |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.DSR 2023/5.9.2 |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and accessplatformDSR 2023/5.9.3 |
| 18 | Supply of 25 mm dia cpvc pipe including all complete.SOR2022/88 |
| 19 | Road Signages & Road Safety |
| 20 | Electrical Work |
| 21 | Supply ,fixing, testing & commissioning of 7 mtr decorative pole with single arm bracket .Pole made from continuously tapered circular hot rolled steel pipe conferming to E250 grade as per IS 2062 :2011 standards.Total hight of pole with bracke shall be 7000mm nominal above the ground floor.Base plate is made of 10mm/12mm MS sheet base so designed that the foundation bolt are not visible .The pole dimensions are a bottam diameter 166mm ,topndiameter of 76 mm and thickness of 3mm .the bracket stem is constructed from circular pipe 76.1 mm diameterand 2.6mm thickness ,crowned with a mild steel (MS) cone 700 mm hight of at the top.The pole are painted with multiple coat of weather resistant polyurethane paint the service window at the lower part of the pole contains connector,cutouts & MCB etc.The single arm bracket is made out of steel section of vairious diameters the bracket can be made as per top of pole diameter.The RCC foundation of pole also included with 450mm long x16mm dia foundation bolt .The bidder should be Submit the sample of pole for approval of paint and designe. The waranty of each part of equipment should be minimum 5years. Make-as per approved UP PWDMR |
| 22 | Supply, fixing ,testing & commissioning of IP 65 protection 120 watt post top latern as per approved and suitable for 7 mter decorative pole, the system lumens should be min 9000 lumens.the luminaire efficiency should be 100 lumens/w system wattage should not be more than 120 watt. The colour of lamp should be as per approval of Engineer/Incharge Make as per approved UP PWDMR |
| 23 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed 3core 6 sqmm XLPE cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitablesize or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.The cable will be connect to existing Electrical Panel.Make-UP PWD ApprovedSOR(E) 2022/501 |
| 24 | Supply and laying below 750mm of 63mm dia DWC HDPE pipe including digging and backfilling and repairing of any cutting of road cutting as directed by Engineer Incharge.Make as per UP PWD approved.DSR 2022/14.16.1 |
| 25 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. CertifiedSOR(E) 2018/726 (C) |
| 26 | EXTERNAL LIGHTING PANEL-1Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all Respect. Including 16 A SP MCB .All equipments shall be UP.PWD approved.DSR 2022/807 |
| 27 | INCOMER1 No. 32 A DP MCB,10 kA breaking capacity.DSR 2022/1009 |
| 28 | OUTGOINGS16A DP MCBProvide the space in panel for provision of CCMS System.And Energy Meter DSR 2022/1002 Please Enable Macros to View BoQ information |