| 1 | Dragging, loading, carriage and unloading of following store materials with proper stacking from ESCSitapur to JE dumps store and from JE dump store to work site within Mehmudabad area. |
| 2 | 11 KV 3x185 sq mm XLPE cable |
| 3 | 11 KV 3x185 sq mm O/D |
| 4 | 11 KV 3x185 sqmm St/Th |
| 5 | ACSR Weasel Conductor |
| 6 | ACSR Rabit Conductor |
| 7 | 11 Mtr ST Pole |
| 8 | 13 Mtr ST Pole |
| 9 | 8.5 Mtr PCC Pole |
| 10 | 11 kv pin insulator with pin |
| 11 | 11KV Top chanal |
| 12 | 11KV Droper chanal |
| 13 | S/S ANGLE 75X75X6 |
| 14 | 11kv dise insulater |
| 15 | M S Earthing Rod 20x2500 mm |
| 16 | ABC CABLE 1X25+1X16 SQMM |
| 17 | ABC CABLE 3X50+1X35+1X16 SQMM |
| 18 | ABC CABLE 3X95+1X70+1X35 SQMM |
| 19 | L T XLPE CABLE 1X400 SQMM |
| 20 | L T XLPE CABLE 1X240 SQMM |
| 21 | LT XPLE CABLE 3.5X400 sqmm |
| 22 | L T XLPE CABLE 3.5X240 SQMM |
| 23 | L T XLPE CABLE 3.5X120/150 SQMM |
| 24 | L T XLPE CABLE 3.5X70 SQMM |
| 25 | 33kv dise insulater B&S TYPE |
| 26 | 33kv dise fITTING B&S TYPE |
| 27 | 33 KV PIN INSULATOR |
| 28 | 11 KV TYPE STEEL X-ARM |
| 29 | Ms CHANNEL 125X65X1300mm (T-OFF) |
| 30 | 33kv Top CHANNEL 125x65x6 3200mm |
| 31 | Droper Channel 100x50x6 2600mm |
| 32 | DISTRIBUTION BOX 3 PHASE |
| 33 | Stay Set 16x1800 Complete |
| 34 | Stay wire 7/10swg |
| 35 | GI wire10swg |
| 36 | Making Trench / Pit For st. thr. 11 KV 3x185 sq mm XLPE with digging and refilling of trench/pit. |
| 37 | Arrangement for Fixing of cable out door jointing Kit 11 KV 3x185 sq mm XLPE |
| 38 | Fabrication & erection of single pole for 11 KV /LT lline on 8.5 M long PCC Pole with fixing of necessary clamp & other acessories like Channel, cross arm, Danger board, barbed wire, Fbracket, etc. contractor shall provide, all material except pole ,Chanals,xarm ,Pin insulator ,disc insulator as per RESPO norms. ( Digram as per tender specification) |
| 39 | Fabrication & erection of 11 KV cable exposure type double pole on 11 mtr with the provission of separate bus bar for each cable with fixing of necesory clamps and other acessories like danger board,number plate,barbed wire, 9 no. pin insulators with pins,1 no. channels 65x65 mm (1600mm each),1 no.MS channel 65x65mm(2800mm in length) and 2 no.MS angle 65x65x6 mm (each 2800mm in length ) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size of lug. (all material arranged by contractor except pole,PVC aluminium cable & insulator,chanal ,angle).as per RESPO norms. ( Digram as per tender specification) |
| 40 | End Type Double Pole- Fabrication, erection, of double pole of end terminations with one side cable exposure for 11 KV line on 11mtr/8.5 M long PCC pole with fixing of necessary clamps & other accessories like disc insulator, 1 no. top chennel 65×65 mm - 2.8M & 1 no. gaurding angle and 1 no. X bracing,disc fittingits, 11kv pin with pin insulator ,danger board,number plate,barbed wire,jumpering by PG clamp 4 no stay complete work (all material arranged by contractor except insulator,disc insulator with fitting ,Stay ,chanals,angle, Pvc cable & pole).as per RESPO norms. ( Digram as per tender specification) |
| 41 | Double Pole- Fabrication, erection, of double pole for 11 KV line on 11mtrSTP/8.5 M long PCC pole with fixing of necessary clamps & other accessories like disc insulator, 1 no. top chennel 65×65 mm - 2.8M, 1 no. X bracing,disc fittingits, gaurding angle, 11kv pin with pin insulator ,danger board,number plate,barbed wire,jumpering by PG clamp 4 no stay complete work (all material arranged by contractor except insulator,disc insulator with fitting, stay set chanals angle & pole).as per RESPO norms. |
| 42 | S/S Type Double Pole- Fabrication, erection, of double pole FOR TRANSFORMER INSTALLATION AND COMMISING on 11mtrSTP/8.5 M long PCC pole with fixing of necessary clamps & other accessories like disc insulator, top channel 65×65 mm - 2.8M, Dropper Channel TRANSFORMER BASE ANGLE, 11KV FUSE SET, 11kv pin with pin insulator ,danger board,number plate,barbed wire,jumpering by PG clamp 4 no stay complete work (all material arranged by contractor except insulator,disc insulator with fitting & pole transformer ).as per RESPO norms. ( Digram as per tender specification) |
| 43 | Double Pole For Road Xing - Fabrication, erection, of double pole for 33 KV line on 13 M long ST pole with fixing of necessary clamps & other accessories like disc insulator, 9 no. 33kv Top CHANNEL 125x65x6 3200mm - 1 no. X bracing,disc fittingits, gaurding angle, 33kv pin with pin insulator ,danger board,number plate,barbed wire,jumpering by PG clamp , stay complete work (all material arranged by contractor except insulator,disc insulator with fitting, stay set,chanal ,angle & pole).as per RESPO norms. |
| 44 | Laying of 11 KV XLPE cable |
| 45 | CABLE LAYING BY Manual METHAD in trench (11 KV XLPE CABLE Provide by department ) |
| 46 | Hoisting of 11 KV XLPE cable on double pole with GI pipe of size 6\\" dia 3 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor except 11 kv cable). |
| 47 | Laying Stringing & Sagging of LT ABC (1X25+1X16) Sq mmas per RESPO Norms |
| 48 | Laying Stringing & Sagging of ABC CABLE 3X50+1X35+1X16 SQMM as per RESPO Norms. |
| 49 | Laying Stringing & Sagging of ABC CABLE 3X95+1X70+1X35 SQMM as per RESPO Norms. |
| 50 | Laying Stringing & Sagging of three phase 11 kv line on ACSRWeasel conductor as per RESPO Norms. |
| 51 | Laying Stringing & Sagging of three phase 11 kv line on ACSRRABIT conductor as per RESPO Norms. |
| 52 | Gauarding of O/H Line - Fabrication and fixing of gaurding angle on single/double Poles as per RESSPO Norms including provision of all necessary clamps and hooks.Shifting of existing line conductor of 11 KV/LT lines to maintain proper clearence in between both Lines.(ALL TYPE CLAMP NUT BOLT PROVIDE By CONTRACTOR) |
| 53 | Ordinary Earthing of pole by M.S. Earthing Rod 20x2500mm with GI wire as per Resspo Norms only earting rod & G I wire provided by deptt other all material provide by contractor |
| 54 | Digging of Pit in kachcha/Pakka land in depth upto 1/6 length of Pole, Dragging of STP /pcc from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 11 KV line on 11 M long ST/8.5Mtr PCC Pole and refilling with ramming of earth. |
| 55 | Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms. |
| 56 | Construction of pole plinth 300mm x 450 mm above ground level in 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms. |
| 57 | High Pressure Testing and fault location of 11 KV cables/line/ as per norms |
| 58 | Tree branches cutting and chopping where required |
| 59 | Dismentaling and installation of Transformer. |
| 60 | SHIFTING OF EXISTING 11KV XLPE CABLE WITH ALL ASSOCIATED WORK AS RESTORING OF DAMAGE CABLE WITH THROUGH JOINTING KIT OR ANY OTHER WORK |
| 61 | Grouting of stay |
| 62 | supply Cable end termination using compression brass glands and crimping type Aluminium Thimbles of different sizess insulated cable sizes as per T.S. |
| 63 | CABLE JOINT KIT ST FOR CABLE 3.5X240 Sqmm |
| 64 | CABLE JOINT KIT ST FOR CABLE 3.5X150 Sqmm |
| 65 | CABLE JOINT KIT ST FOR CABLE 3.5X70 Sqmm |
| 66 | GLAND OF SIZE 400 Sqmm |
| 67 | GLAND OF SIZE 240 Sqmm |
| 68 | GLAND OF SIZE 150 Sqmm |
| 69 | GLAND OF SIZE 70 Sqmm |
| 70 | Supply & Erection of Al. crimping lugs of 400 sq.mm. |
| 71 | Supply & Erection of Al. crimping lugs of different sizes 240/sq.mm. |
| 72 | Supply & Erection of Al. crimping lugs of different sizes 150/120 sq.mm. |
| 73 | Supply & Erection of Al. crimping lugs of different sizes 70 sq.mm. |
| 74 | Supply & Erection of Al. crimping lugs of different sizes 16 sq.mm. |
| 75 | Supply & Erection of Al. crimping lugs of different sizes 10 sq.mm. |
| 76 | Spply of Outdoor type LT Distribution Boards with a rupturing capacity of 50ka at 415V or as called for individual items openable in front and back suitable for 3 phase, 4wire 50Hz AC supply and an ambient temperature of 45 deg. C. the Cubicle should be weather proof, dust proof vermin proof and enclosure protection shall be IP-55 as per IS 2147-1962 and IS 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel and provided with 16 SWG hinged doors including suitable foundation two earthing Electrode 20mm with clamps and 50X6mm GI strip MAIN LT PANEL AT SUBSTATION- 250KVA / 400 KVA(Type A-1)Incomer-1 Set of 630 Amp. TP MCCB with Spreader & Extended hndle Metering on Incomer- 1 Set of Digital Ammeter with ASS1 Set of Digital Voltmeter with VSS1 Set of LED type phase Indicating Light (22.5mm) with Control MCBs Outgoing - 6Set of 250 Amp TP MCCB with Spreader & Extended handle (5 Nos+ 1 No for capactior panle) -2 Set of 100 Amp. TP MCCB with spreder & Extended handle. |
| 77 | Spply of Outdoor type LT Distribution Boards with a rupturing capacity of 50ka at 415V or as called for individual items, openable in front and back suitable for 3 phase, 4wire 50Hz AC supply and an ambient temperature of 45 deg. C. the Cubicle should be weather proof, dust proof vermin proof and enclosure protection shall be IP-55 as per IS 2147-1962 and IS 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel and provided with 16 SWG hinged doors including suitable foundation two earthing Electrode 20mm with clamps and 50X6mm GI strip. Sub pannel of Distribution. (Type B-1)Incomer-1 Set of 250 Amp. TP MCCB with Spreader & Extended hndle Metering on Incomer- 1 Set of Digital Ammeter with ASS1 Set of Digital Voltmeter with VSS1 Set of LED type phase Indicating Light (22.5mm) with Control MCBs Outgoing - 6Set of 100Amp TP MCCB with Spreader & Extended handle (2 Nos+ 1 No for capactior panle) -1 Set of 63Amp. TP MCCB with spreder & Extended handle. |
| 78 | Supply , installation, testing & commissioning of Lockable distribution boxes of size 450X400mm with bus bar 100 Amp. TPN to feed upto 10 houses including structure (of MS Angle 65x65x6) for ground mounting with proper grouting (Type C) with MS Angle 65x65x6 mm for support of C-Type box ( as per GTP Approved by MVVNL) All Material provided by the contractor |
| 79 | Holding of exsting LT overhead line on exsting D/P or S/P for enabling removal of conductor on one side of LT overhead line ,its stringging on D/P or S/P .(agency also to provide temporary stay at the time of dismantaling of overhead line) |
| 80 | Construction of plinth suitable for following equipments with civil material as per requirement. |
| 81 | LT main pillar box |
| 82 | LT mini Pillar |
| 83 | Fabrication, Installation & reconectioning of C-Type Boxes support size of 7'x7' height as per diagram |
| 84 | Construction of massonary type T/F plinth of size 2x2x1½ M with fixing of two nos. Channel on the top of the plinth.RCC slab of 4\\" thick on the top of the plinth, plastering outer surface of walls and its proper curing for erection and commissioning of 11/0.4 KV 250 KVA T/F. |
| 85 | Fabrication, erection, grouting, plinthing & painting of wiremesh fencing 3 M height with M.S Angle 50x50x6 and wiremesh 10 SWG. The work also includes making of retaining wall as per norms . |
| 86 | Dismenteling and installation of distribution transformer with all acceseries |
| 87 | Opening of consumer connection from existing line and again reconnection with newly erected LT distribution box/Pillar box (necessary cable of suitable size shall be provided by contractor) |
| 88 | Single phase CONNECTION |
| 89 | Three phase CONNECTION |
| 90 | Camical Earthing (one earthing for each A & B panal, one neutral ) |
| 91 | Well type pipe earthing depth 40 fit with GI Pipe (20 mm Dia) and 50x6 mm GI Strip with clamp. (All material provided by the contractor)(One earthing each transfarmer Neutral) |
| 92 | Earthing for C- Pannels & One Earthing For Each A And B-TYPE PANNEL(Body) WITH MS ERATHING ROD with GI Strip 25x6 mm with clamp (All material provided by the contractor) |
| 93 | Back Filling and Road Restoration Charges (Kaccha Road/Pucca Road) |
| 94 | SHIFTING OF OUTDOOR TYPE DISTRIBUTION PANNEL(C-TYPE) |
| 95 | SHIFTING OF OUTDOOR TYPE DISTRIBUTION PANNEL(A-TYPE & B-TYPE) |
| 96 | CABLE LAYING CHARGES OF LT XLPE CABLE |
| 97 | Rectification of 11kv / LT Overhead line ,Re-tensioning of conductors, Damaged stay and hardware replace |
| 98 | Dismentaling and Extraction of old poles ensuring the pole is reusable and back filling of pit Safe carraige site to dump site |
| 99 | LT FUSE SET FOR 10KVA,16KVA,25KVA,63KVA & 100KVA T/F |
| 100 | HT FUSE FOR DIFFERENT TYPE OF TF |
| 101 | Dismentaling of HT /LT Line |
| 102 | Safe Carriage of Dismental Line material from work site to ESC, Sitapur Store 0-80 KM with Loading and Unloading Charges. Please Enable Macros to View BoQ information |