| 1 | Loading, Unloading and safe cartage of the following materials from Electricity Store Centre, Bahraich to the work site/dump site. All the material at Sl. No. 1 shall be given by department and rest all the material including civil material will be arranged by the contractor itself. Any other material if required for completion of work which might not have been mentioned in bid document, shall be arranged by the contractor. (De-Centralized Items Provided by the Contractor as per Estimate). |
| 2 | Cartage of PCC Pole 8.5 Mtr. Long |
| 3 | Cartage of PCC Pole 11 Mtr. Long |
| 4 | Safe Carriage of ABC (3*50+1*35+1*25) SQMM. |
| 5 | Safe Carriage of ABC (3*95+1*70+1*16) SQMM. |
| 6 | Safe Carriage of ABC (3*95+1*70+1*35) SQMM. |
| 7 | Safe Carriage of ABC (3*120+1*95+1*16) SQMM. |
| 8 | Cartage of stay sets complete. |
| 9 | Earthing |
| 10 | Distribution Box 3 Phase |
| 11 | ACSR Weasal conductor |
| 12 | Carriage of Other line material |
| 13 | Carriage of LT XLPE cable All.3.5*240sqmm |
| 14 | Carriage of LT XLPE cable All.3.5*150sqmm |
| 15 | Carriage of LT XLPE cable All. 1*120sqmm |
| 16 | Carriage of B-Type Pannel Suitable for 06 outing MCCB |
| 17 | C-Type Pannel |
| 18 | Erection workMinium depth of laying from ground surface to the top of cable as per IS is-i) Low Voltage (1.1 KV) and Control Cable - 0.75 Mtr.ii) 3.3 KV to 11 KV Cables - 0.90 Mtr.iii) 22 KV to 33 KV Cables - 1.05 Mtr.iv) Cables at Road Crossing - 1.00 Mtr. v) Cables at railway level crossings (measured from bottom - 1.00 Mtr.of sleepers to the top of Pipe)Note 1) - The depth may be increased but not more than 1.6 M2)- The standard depth and width for laying the cable are also attached (as per letter No. 561/Director(Tech.)/MVVNL/Camp/Dt. 09-01-26 561 with the tender form. |
| 19 | Erection of Singal PCC Pole (8.5 Mtr Long) for 11 KV/HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. |
| 20 | Erection of Singal PCC Pole (11 Mtr Long) for 11 KV/HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. |
| 21 | Earthing Complete as per RESSPO Norms. |
| 22 | Fixing of B type pannel (for all size)as per RESSPO Norms. |
| 23 | Fixing of C type pannel (for all size)as per RESSPO Norms. |
| 24 | Fixing of Distribution Box 3 phas as per RESSPO Norms. |
| 25 | Grouting of Poles with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely. All required materials shall be provided by the contractor at his own cost. |
| 26 | Errection & Commissioning of ABC (3*50+1*35+1*25) SQMM. including fitting of Accessories (All Accessories shall be Provided by the Contractor). |
| 27 | Errection & Commissioning of ABC (3*95+1*70+1*16) SQMM. including fitting of Accessories (All Accessories shall be Provided by the Contractor). |
| 28 | Errection & Commissioning of ABC (3*120+1*95+1*16) SQMM. including fitting of Accessories (All Accessories shall be Provided by the Contractor). |
| 29 | Errection & Commissioning of ABC (3*95+1*70+1*35) SQMM. including fitting of Accessories (All Accessories shall be Provided by the Contractor). |
| 30 | Laying, stringing, sagging & binding of ACSR Weasal conductors of 1.1 kv line for neutral singal circuit (where as required). |
| 31 | Erection and Grouting of stay sets alongwith complete fittings. Cement, Sand & Brick ballast provided by the contractor at his own cost. |
| 32 | Dragging & Laying of LT XLPE Cable (3.5*400/3.5*250/3.5*150/1*120/1*400sqmm) in trench with sand & brick and back filling as per Respo Norms. |
| 33 | (Decentralized Items Provided/Fixing/Erection/Installation/Laying by the Contractor as per Respo Norms). |
| 34 | LT Clamp |
| 35 | LT Clamp with I Hook |
| 36 | Eart wire Clamp |
| 37 | Suspension Clamp |
| 38 | Piercing Clamp/connector |
| 39 | Dead ind clamp |
| 40 | All lug for 150 & 240 & 400 sqmm cable |
| 41 | LT Outdoor Cable Box for All size |
| 42 | Clamp for LT Distribution Box (for All size) |
| 43 | Alluminiume Lug for All Size Cable |
| 44 | Connecting Lead |
| 45 | Stone pad Please Enable Macros to View BoQ information |