| 1 | Safe loading Carriage including unloading and proper stacking of following materials from central store Barabanki to site of work. |
| 2 | PCC Pole 8.5 Mtr |
| 3 | Earthing Set Complete |
| 4 | ACSR Weasel Conductor |
| 5 | 11 kv Polymer Pin Insulator |
| 6 | 11 kv Polymer Disk Insulator with Fitting |
| 7 | 11 KV XLPE Cable 3x70 Sq.mm. |
| 8 | 11 KV XLPE Cable 3x185 Sq.mm. |
| 9 | 11 KV 3x70 sqmm XLPE O/D Cable Box Jointing Kit |
| 10 | 11 KV 3x185 sqmm XLPE O/D Cable Box Jointing Kit |
| 11 | 11 KV 3x70 sqmm XLPE Cable Box Straight Through |
| 12 | 11 KV 3x185 sqmm XLPE Cable Box Straight Through |
| 13 | Stay Wire 4 mm 7/8 SWG |
| 14 | Top Channel |
| 15 | Dropper Channel |
| 16 | MS-Cross Basing Angle 65x65x5 with Clamp |
| 17 | 11 kv 'V' Type Cross Arm |
| 18 | T-off Channel |
| 19 | Stay Set Complete |
| 20 | F-clamp 11 kv |
| 21 | Dragging of pole from JE Dump Store to site |
| 22 | Grouting of Pole in depth of 1/6th the length of pole in ratio 1:4:8 in cement sand and brick ballast and construction of pole plinth 300mmx45mm above ground level in 1:2:4 in cement, coarse sand and stone grit as per respo norms. |
| 23 | Concreating of Stay |
| 24 | Erection of Substation type single pole with PCC 8.5 Mtr. Long including mounting of Top Channal, base angle with clamps with nut & bolt 33/11 KV line. |
| 25 | Stringing and sagging of 11 KV line with ACSR Weasel Conductor including nuzzling binding and jumpering (weasal conductor will be provided by the department) |
| 26 | Earthing of pole with MS Earthing. |
| 27 | Providing & Fixing of various type materials. All materials shall be supplied by the contractor. |
| 28 | Nut & Bolt |
| 29 | Clamp for Top/T-off/Dropper |
| 30 | GI Pipe dia 6/8 |
| 31 | Clamp for 11 kv 'V' Type Cross Arm PCC with Nut & Bolt |
| 32 | PG Clamp for ACSR Conductor |
| 33 | Laying of 11 kv XLPE Cable AL. 3x185Sq.MM S/C by HDD(Drill Method) as per Respo Norms.(All the material required for laying will be supplied by the contractor except 11 kV XLPE cable) |
| 34 | Fixing of 11 KV 3x70 sqmm XLPE O/D Cable Box Jointing Kit |
| 35 | Fixing of 11 KV 3x70 sqmm XLPE Cable Box Straight Through |
| 36 | Fixing of 11 KV 3x185 sqmm XLPE O/D Cable Box Jointing Kit |
| 37 | Fixing of 11 KV 3x185 sqmm XLPE Cable Box Straight Through |
| 38 | Testing of Cable |
| 39 | Hosting of 11 kv XLPE Cable AL. 3x70+3x185Sq.MM on DP with GI pipe 6\\" its Jumpring complete with clamps, nut and bolts. (All material will be Provided by the contractor except 11 kv cable & O/D J/K. as per RESPO NORMS. |
| 40 | Dismantling of 11 kV grade underground XLPE cable of any size (up to 3•185 sq.mm), including excavation of trench, removal of cable carefully without damage, coiling, loading, transportation to departmental store, unloading, stacking and accounting, complete in all respects. |
| 41 | Other line work Please Enable Macros to View BoQ information |