| 1 | Preventive maintenance and monthly servicing and check up of Bitzer make, new BV yard Blast cold storage 25 HP of 1 units including 1 ODU+ 1 IDU (-)30 °C operation wih R- 404A refrigerant gas two stage, semi hermatically sealed compressor controlled with electronically operated solinoid valve for liquid system,complete all as specified and directed. |
| 2 | All as per item no 01, here-in-before but new BV yard meat room of cold storage (-)18 °C with capacity 6 HP having 01 units including 1 ODU +1 IDU complete all as specified and directed. |
| 3 | All as per item no 01, here-in-before but new BV yard Fish room of cold storage (-)18 °C with capacity 4 HP having 01 units including 1 ODU +1 IDU complete all as specified and directed. |
| 4 | All as per item no 01, here-in-before but new BV yard Vegetable room of cold storage (+) 4 °C capacity 6 HP having 01 units including 1 ODU +1 IDU complete all as specified and directed. |
| 5 | All as per item no 01, here-in-before but new BV yard Egg room of cold storage (+) 4 °C capacity 4 HP having 01 units including 1 ODU +1 IDU complete all as specified and directed. |
| 6 | All as per item no 01, here-in-before but new BV yard Ante room of cold storage (+) 4 °C capacity 6 HP having 01 units including 1 ODU +1 IDU complete all as specified and directed. |
| 7 | All as per item no 01, here-in-before but new BV yard Milk room of cold storage (+) 4 °C capacity 2 HP having 01 units including 1 ODU +1 IDU complete all as specified and directed. |
| 8 | Preventive maintenance and monthly and check up of old BV yard Bitzer Blast cold storage 48000 BTU of 1 unit including 1 ODU+ 1 IDU (-)30 °C operation wih R- 404A refrigerant gas two stage, semi hermatically sealed compressor consisting 4 cylinder, controlled with electronically operated solinoid valve for liquid system,complete all as specified and directed. |
| 9 | Preventive maintenance and monthly and check up of old BV yard Danfoss cold room plant (-)18 °C with(50000 BTU) of 1 unit including 1 ODU + 1 IDU, R- 404 A Regrigerant.The compressor hermatically sealed , equipped with electronically controlled solinoid valve system. The system have individual accumulated to varify and controll the liquid gas flow including micro processor controlled electrical panel indoor blower unit controlled with fans and other electrical circuites with electronically operated solenoid valve for liquid system,complete all as specified and directed |
| 10 | All as per item no 09, here-in-before but old BV yard Vegetable room of cold storage (+) 4 °C capacity 30000BTU having 01 units including 1 ODU +1 IDU complete all as specified and directed. |
| 11 | All as per item no 09, here-in-before but old BV yard Egg room of cold storage (+) 4 °C capacity 20000BTU having 01 units including 1 ODU +1 IDU complete all as specified and directed. |
| 12 | Preventive maintenance monthly and check up of Blue star cold room at sanjivani hospital temp to be stabled +4 °C with capacity upto 15000 BTU of 1 units including 1 IDU+2 ODU ,R-404A Refrigerent inculding in door blower unit equipped with electrically operated micro processor controll panel including blower fans and other other lectrical circuites of the system to be checked complete all as specified and directed. |
| 13 | Preventive maintenance and monthly and check up of Blue star cold room at sanjivani hospital temp to be stabled +4 °C with capacity upto 12000 BTU of 1 units including 1 IDU+1 ODU ,R-22 Refrigerent inculding in door blower unit equipped with electrically operated micro processor controll panel including blower fans and other other lectrical circuites of the system to be checked complete all as specified and directed. Please Enable Macros to View BoQ information |
| 14 | Preventive maintenance and monthly and check up of Blue star cold room at sanjivani hospital temp to be stabled +4 °C with capacity upto 12000 BTU of 1 units including 1 IDU+1 ODU ,R-22 Refrigerent inculding in door blower unit equipped with electrically operated micro processor controll panel including blower fans and other other lectrical circuites of the system to be checked complete all as specified and directed. Please Enable Macros to View BoQ information |