| 1 | M&L for cleaning and maintenance of sewage line / system from first manholes upto the final drop outlet into the septic tank or central sewage system in running/flowing order without blockage having inner dia of pipe from 150mm to 300mm and depth varying upto 3 mtr in any situation manually or mechanically as required including sewage pump, sewage machine, super sucker etc. Complete all as specified & as directed.NOTE :- In case a blockage reoccured with in 10 days, the same shall be removed without any extra cost to the Govt.Cleaning of manhole shall be measured and paid under respective item.No extra payments shall be paid for use of any type of machine ie: Super sucker etc. |
| 2 | M&L for Cleaning and maintenance of sewage line / system from first manholes upto the final drop outlet into the septic tank or central sewage system in running / flowing order without blockage having inner dia of pipe from 150mm to 300mm and depth varying upto 6 mtr in any situation by mechanically as required including sewage pump, sewage machine, super sucker, jetting machine etc complete all as specified & directed.NOTE :- In case a blockage reoccured with in 10 days, the same shall be removed without any extra cost to the Govt.Cleaning of manhole shall be measured and paid under respective item.No extra payments shall be paid for use of any type of machine ie: Super sucker etc. |
| 3 | Taking out sludge water, semi solid or solid materials from manholes up to a depth of 1.5mtr by manually or using super sucker machine, Jet machine, electric motor etc, removing and depositing into excavated pit of suitable size outside of MOD land (incl necessary excavation and earth work in any type of soil) allowing initial percolation of sludge water and finally burying the entire solid/semi solid material completely underground complete all as specified and directed by Engr in Charge. |
| 4 | All as per item No 03 above but depth up to 3.00 mtr complete all as specified and directed |
| 5 | M&L for cleaning of EWCs, IWCs, bottle traps, Nahani Traps, Gully traps and Floor traps etc., removal of blockage in between WC to Nahani trap / WC to Ist manhole / floor trap to nahani trap etc. by flexible roding and removal of all the dirt up to a distance of 100 mtr complete all as specified and as directed .Note:- (i) In case a blockage reoccured with in 10 days, the same shall be removed without any extra cost to the Govt.(ii) cleaning of line in between manholes where complete all as specified and directed. |
| 6 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillers etc complete all as specified and directed. |
| 7 | M&L for brick work with sub class 'B' straight or curved on plan exc 6m mean radius and built in CM 1:4 including demolition of brick work / Stone or boulder masonary built in cement mortar and removing debris beyond MOD land complete all as specified and directed by Engr in Charge. |
| 8 | All as per Srl item no. 07 above but except bricks complete all as specified and directed |
| 9 | M&L for brick work with sub class B bricks, straight or curved on plan to any radius in half brick walls built in in CM 1:4 including demolition of brick work / stone or boulder masonary built in cement mortar and removal of debris beyond MOD lands. Complete all as specified and as directed by Engr in Charge. |
| 10 | Cleaning of drains of inner width up to 0.75 mtr and depth up to 1.2 mtr by removing mud, garbage, debries, sludge, silt and soil of any thickness, vegitation etc by manually or machnically as required. Complete all as specified and as ditrected by Engr in Charge. |
| 11 | Cleaning of RCC / Hume pipe and culvert of any dia and at any depth from ground level chocked will sand, silt, mud, garbage, debries etc. and removal of debries beyond MOD lands. Complete all as specified and as directed. |
| 12 | M&L for PCC 1:3:6 type C-2, (using 40mm graded stone aggregate) as in surface channels and drains incl all moulds and forms etc. requires as per ground conditions complete all as specified and as directed by Engr in Charge. |
| 13 | Extra for forming fair finished drain or channel inner girth up to 55 cm in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engr in Charge. |
| 14 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone agg as in coping, kerbs, bed plates incl weathering slightly rounded or chamfered angle and throating, necessary formwork to obtain a smooth finishes and including demolition of cement concrete and removing debrish beyond MOD land complete all as specified and directed by Engr in Charge. |
| 15 | Excavation in trenches manually or mechanically as per ground requirements n.exc 1.5 mtr wide and n.exc 1.5 mtr depth for fdn etc for soft/loose soil not exc 10 sqm on plan and getting out soft and loose soil complete all as specified & directed by Engr in Charge. |
| 16 | All as per item No. 15 above but exc 1.5 mtr and n.exc 3 mtr in any type of soil complete all as specified and directed |
| 17 | Returning filling in soft/loose soil incl spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified & directed by Engr in Charge. |
| 18 | Removing of surplus soil beyond MOD land complete all as specified and directed by Engr in Charge. |
| 19 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed by Engr in Charge. |
| 20 | S&F 200 mm dia reinforced concrete pipes, class NP2 with collar per length of pipe laid and jointed in trenches. Complete all specified and directed by Engr in Charge. |
| 21 | M&L for cutting of road / path as required for laying of pipe line of any type including repair/make good with filling of earth, boulders, WBM, BM etc. with top surface finished with 50mm thick ready mixed patch filler, Complete all as specified and as directed by Engr in Charge. |
| 22 | M&L for Salt-glazed stoneware drain pipes 150mm interenal dia grade ‘A’ incl testing and laid in trenches and jointed as specified to a level on concrete bed including demolition of any types of pipes set in cement mortar, removing debris's beyond MOD land complete all as specified and directed by Engr in Charge. |
| 23 | M&L for Salt-glazed stoneware drain pipes 200mm interenal dia grade ‘A’ incl testing and laid in trenches and jointed as specified to a level on concrete bed including demolition of any types of pipes set in cement mortar, removing debris's beyond MOD land complete all as specified and directed by Engr in Charge. |
| 24 | Supply and laying, DWCPE(SN8) 150 mm dia pipes and snap fit coupler etc as per site requirements including testing and laid properly, jointed laid in trenches as specified to a level on concrete bed including demolition of any types of pipes set in cement mortar etc., removing debris beyond MOD land complete all as specified and directed by Engr in Charge. |
| 25 | Supply and laying, DWCPE(SN8) 200 mm dia pipes and snap fit coupler etc as per site requirements including testing and laid properly, jointed laid in trenches as specified to a level on concrete bed including demolition of pipes set in cement mortar etc., removing debris's beyond MOD land complete all as specified and directed. |
| 26 | M&L for 100mm thick cement concrete 1:4:8 type D-2 using 40mm graded agg in packing under and haunching against sides of 150mm dia (Internal dia) pipe of any types after they are laid and tested including demolition of old concrete and removing debrish beyond MOD land complete all as specified and directed by Engr in Charge. |
| 27 | M&L for 150mm thick cement concrete 1:4:8 type D-2 using 40mm graded agg in packing under and haunching against sides of 200mm dia (Internal dia) pipe of any types after they are laid and tested including demolition of old concrete and removing debrish beyond MOD land complete all as specified and directed by Engr in Charge. |
| 28 | Demolition of cement concrete of any description and in ground floor and paving complete all as specified and directed. |
| 29 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete, bed concrete of pipe, manholes, drain, sub base under tiles etc. Complete all as specified and directed by Engr in Charge. |
| 30 | M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection / hard standing 75mm thick laid in bays and surfaces finished even and fair, including filling the joints with bitumen mastic. Complete all as specified and as directed by Engr in Charge. |
| 31 | Taking down cement or cement lime plaster of any layers on walls, concrete surfaces incl racking out joints, hacking for keys, scrubbing down with water etc and removal of rubbish beyond MOD land complete all as specified and directed. |
| 32 | M&L for rendering 15 mm thick in CM 1:4 on faces of new / old bricks works or concrete surfaces (including garrage chajja, facia and ceiling) etc. finished even and smooth without using extra cement. Complete all as specified and as directed by Engr in Charge. |
| 33 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer for matching old and new surfaces complete all as specified and directed by Engr-in-charge.. |
| 34 | M&L three coat of white washing on newly / old plastered surfaces including preparation of surfaces. Complete all as spd and as directed. |
| 35 | M&L for 40 mm thick PCC 1:2:4 type B-1 ( 20 mm graded stone aggre) as floors finishing surfaces (Including top of roof on garrage) finished even and smooth using extra cement including demolition of old concrete and removing debrish beyond MOD land complete all as specified complete all as specified & directed. |
| 36 | M&L for complete removal of existing treatment of wall surfaces etc. using wire brush/mechanical/ electrical driven sanders, washing, rubbing down and stopping of painted surface including preparation of surface etc and applying two coats of cement base paint complete all as specified and directed by Engineer-in-charge. |
| 37 | S&F for Precast 75mm thick SFRC manhole/drain covers of size exc 0.30sqm but not exc 0.90 sqm each set and jointed in cement mortar 1:4 including demoliton of PCC drain / manhole cover and removing debrish beynd MOD land complete all as specified and directed by Engr in Charge. |
| 38 | M&L for reinforced cement concrete using type B1, 1:2:4 (20mm graded aggregate) as in cover slab og manhole, GT and drain of any thickness and any size supported on walls etc and set in 1:4 cement mortar including demolition of manhole / drain / GT covers etc. and removing debrish beyond MOD land. Complete all as specified and directed by Engr in Charge. |
| 39 | M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed. |
| 40 | Dismantling of cast iron drain pipes, jointed in cement mortar and taking out of trenches, if required, Internal dia of pipe 100mmomplete all as specified & directed. |
| 41 | S&F 100mm bore cast iron soil waste or vent pipes sand cast type in any length with or without ears with lead joints laid in trenches or in floors / walls omplete all as specified & directed. by Engr in Charge. |
| 42 | Dismantling of any type of tiles Paver block or Chequerd tiles etc. Complete all as specified and as directed. |
| 43 | M&L for machine pressed precast concrete glossy interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement & pigment including demolition/dismantling of PCC/tiles and removing debrish beyond MOD land complete all as specified and directed by Engr in Charge. |
| 44 | All as per Srl item no. 43 above but except tiles omplete all as specified & directed. |
| 45 | M&L for sand filling under floors as cushion bed for interlocking paver blocks complete all as specified and directed byb Engr in Charge. |
| 46 | M&L for machine pressed colour glossy finished chequered cement concrete tiles of 300x300x25 mm thick set jointed and pointed in neat cement slurry in floors with grey cement and pigment including 15 mm thick screed bedding layer in cm 1:6 complete all as specified and directed. |
| 47 | S&F for 110mm PVC (SWR) rainwater pipes single socketed in any length with rubber ring joints fixed to walls, laid in trenches or floors etc. including dismantling old of AC/PVC pipe with fittings etc complete all as specified and directed by Engr in Charge. |
| 48 | S&F for 200mm PVC (SWR) rainwater pipes single socketed in any length with rubber ring joints fixed to walls, laid in trenches or floors etc. including dismantling old pipe of any type etc. complete all as specified and directed by Engr in Charge. |
| 49 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, demolition of kerb stone, concrete etc. and removal of debris beyond MOD lands. Complete all as specified and as directed by Engr in Charge. |
| 50 | M&L for two coats of synthetic enamel Paints over one coat of primer including preperations of surfaces on new / old Cement Surfaces etc. Complete all as specified and as directed by Engr in Charge. Please Enable Macros to View BoQ information |