| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 2 | Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 3 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means |
| 4 | Supplying and erecting centering for vertical plain/ RCC concrete walls of supply channel, retaining wall etc upto 90Cm height with necessary supports,all cross bracing with mild steel size of 90cm x60 cm and gauge BG 10 stiffened with welded mild steel sheet angles of size 25 mm x25 mm x3mm for bearing laid silver Oak/ Country wood joist of size 7.50 cm x5.0 cm spaced @ about 90 cm C/C and supported by Casurina props of 10 cm to 13 cm spaced @ 75 cm C/C etc,, complete complaying with standered specfications and as directed by the departmental officers. - Plinth Beam |
| 5 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 |
| 6 | Centering for soffits of RCC slabs of plane surface like columns ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 |
| 7 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. |
| 8 | Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 8 3/4” x 4 1/4” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 9 | Supplying and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. |
| 10 | Manufacturing supplying and fixing of MILD STEEL DOOR made out of 50 x 50 x 6 mm M.S angle for outer frame,35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets (18 G) with 5Nos, of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase of Double shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers. |
| 11 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 12 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors. |
| 13 | Manufacturing supplying and fixing of MILD STEEL Window made out of 40 x 40 x 6 mm M.S angle for outer frame, 35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets ( 18 G ) with 5Nos,of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase of Double shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers. |
| 14 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement |
| 15 | Dadooing walls with ceramic tiles of sizes 300mm X 450mm X 8mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 16 | Plastering the surface of walls with Cement Mortar 1:4 (One cement and Four plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 17 | Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 18 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 19 | Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. |
| 20 | Supplying and filling the basement with Good Earth filling in layers of not more than 15cm thick well rammed watered and compacted - etc., complete complying with standard specification. |
| 21 | Wiring with 2x1.5 sq.mm(22/0.30) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC Rigid pipe consealed in wall and ceiling with PVC accessories in flush with wall in 3mm thick hylum sheet cover with T.W.switch box and 5A FT switch with continius Earth wire connection of SWG TC wire for making good of the consealed portion with suitable colour for PVC consealed light point (for Electronic Regulator)SD 24 |
| 22 | Wiring with 2x1.5 sq.mm(22/0.30) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC Rigid pipe consealed in wall and ceiling with PVC accessories in flush with wall in 3mm thick hylum sheet cover with T.W.switch box and 5A FT switch with continius Earth wire connection of SWG TC wire for making good of the consealed portion with suitable colour for PVC consealed fan point/fan (for Electronic Regulator)SD 23 |
| 23 | Wiring with 2x1.5 sq.mm(22/0.30) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC Rigid pipe consealed in wall and ceiling with PVC accessories in flush with wall with 150mmx100nnx113mm TW switch box with 3mm thick hylum sheet cover for 5A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the consealed portion with suitable colour for consealed PVC plug point SD 38.Complete as per standard specification. |
| 24 | Supply and fixing of 32A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD Earthing. |
| 25 | Supply and run of 2 of 1.50sqmm (22/0.30) PVC insulated SC unsheated copper conductor of 1100V grade on 7/20GI bearer wire for service connection mains SD 64 |
| 26 | Providing rain water harvesting using 6 No.of RCC well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 No. of 6mm dia MS rod vertically and 3 No. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia to a depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with RCC circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm M.S reinforcement at 15 cm spacings on both directions and one 6mm M.S rod ties at the edge of the slab circumferentially including cost of moulding, curing, finishing and well placing in position and disposing off excavated earth with all initial leads and lifts in places as shown by the Departmental officers etc., complete in all respects. |
| 27 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \\"U\\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 28 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 29 | Supply and delivery and fixing of HDPE 1000 litres tank as per IS 12701/1996 including loading,unloading,transportation and labour charges for fixing of the GI pipes and specials for pipe connections works including cutting threading and fixing charges etc., |
| 30 | PVC panelled door shutters hollow type 200mm x 20mm panels with 1mm wall thickness for panels and styles and rails of suitable size with 2mm wall thickness suitably reinforced using MS angle / flat including cost of necessary aluminium hinges and other furniture fittings Please Enable Macros to View BoQ information |