| 1 | vf/k'kklh vfHk;Urk] fo|qr forj.k [k.M++&lxM+h] vktex<+ ds dk;Z{ks= esa lseh VuZ dh ij ¼fctusl Iyku 2026&27½ ds vUrxZr ,y0Vh0 ykbu fuekZ.k ,oa ejEer ,oa izkDdyu ls lEcfU/kr vU; dk;Z ¼fodsUnzhd`r lkexzh QeZ }kjk ns; gksxhA½ |
| 2 | ih0lh0lh0 iksy 8-5 ehVj dh fo|qr Hk.Mkj [k.M+ vktex<+ ls dk;ZLFky rd |
| 3 | ih0lh0lh0 iksy 8-5 ehVj [kM+k djds xzkmfVax dk dk;ZA ¼jsLiks ekuds ds vuqlkj½ |
| 4 | Stay Wire 7/10 SWG fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 5 | Stay Wire 7/10 SWG dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 6 | LT ABC (3x50+1x35+1x16) SQ MM fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 7 | LT ABC (3x50+1x35+1x16) SQ MM dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 8 | A.B. Cable L.T. (3x95)+(1x70)+(1x16) SQ MM fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 9 | A.B. Cable L.T. (3x95)+(1x70)+(1x16) SQ MM dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 10 | Cable L.T. XLPE 3 1/2x70 SQ. MM fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 11 | Cable L.T. XLPE 3 1/2x70 SQ. MM dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 12 | Stay Insulator fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFkya ij |
| 13 | Stay Insulator dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 14 | Earthing Rod 2500x20 mm fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 15 | Earthing Rod 2500x20 mm dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 16 | Cable L.T. XLPE 1x25 SQ. MM fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 17 | Cable L.T. XLPE 1x25 SQ. MM dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 18 | Stay Steel 16x1800MM W.7/10 SWG. Stay wirefo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 19 | Stay Steel 16x1800MM W.7/10 SWG. Stay wire dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 20 | Distribution Box 3 Phase fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 21 | Distribution Box 3 Phase dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 22 | A.B. Cable (3x120+1x95+1x16) SQ MM fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 23 | A.B. Cable (3x120+1x95+1x16) SQ MM dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 24 | G.I. wire 6 SWG fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 25 | G.I. wire 6 SWG dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 26 | Cable L.T. XLPE 3 1/2x150 SQ. MM fo|qr Hk.Mkj [k.M vktex<+ ls dk;ZLFky rd |
| 27 | Cable L.T. XLPE 3 1/2x150 SQ. MM dk;ZLFky ij leLr fQfVax ds lkFk yxkus dk dk;ZA |
| 28 | lkbZV ls [kjkc ,oa iz;ksT; lkexzh dks dk;ZLFky ls fo|qr Hk.Mkj dsUnz] vktex<+ rd ynkbZ@mrjkbZ ,oa igqapkus dk dk;ZA |
| 29 | fofHkUu lkexzh dh vkiwfrZ ,oa LFkkiuk dk dk;ZA |
| 30 | MS Bolt & Nut with 1-washer (Providing by contractor and installatation work) |
| 31 | Stay Clamp (Providing by contractor and installatation work) |
| 32 | Distribution Box Clamp (Providing by contractor and installatation work) |
| 33 | Suspension Clamp (Providing by contractor and installatation work) |
| 34 | Dead End Clamp with Eye Hook (insulated) (Providing by contractor and installatation work) |
| 35 | Alluminium Lug 25 SQ MM (Providing by contractor and installatation work) |
| 36 | J Hook (Providing by contractor and installatation work) |
| 37 | LT Bare Neutari Connector (PG Clamp) (Providing by contractor and installatation work) |
| 38 | Piercing Connector (Providing by contractor and installatation work) |
| 39 | Copper Z-Clamp (Providing by contractor and installatation work) |
| 40 | LT Protection Fuse Set (Providing by contractor and installatation work) |
| 41 | Aluminium Lug 120 MM (Providing by contractor and installatation work) |
| 42 | 11 KV Fuse set (Providing by contractor and installatation work) Please Enable Macros to View BoQ information |