| 1 | Appendix I-CONSTRUCTION OF TOILET BLOCK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 5 | Random rubble masonry in cement mortar 1:6 (1cement:6coarse sand) with hard stone in foundation and basement upto plinth level |
| 6 | DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site |
| 7 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 10 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 11 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more |
| 12 | Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 13 | Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 14 | Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 15 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete |
| 16 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete |
| 17 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 18 | 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 20 | Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 21 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 22 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wallthickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred atcorners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. squaretube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out theframe. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer's specification and direction of Engineer-inCharge. |
| 23 | Providing and fixing factory made panel PVC door shutter consisting of frame madeout of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primersof approved make and manufacture. M.S. frame covered with 5 mm thick heatmoulded PVC 'C' channel of size 30 mm thickness, 70 mm width out ofwhicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both sideforming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall betapered in 45 degree on th inner side to form top and bottom rail and 115 mm widePVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on bothsides to form lock rail. Top, bottom and lock rails shall be provided both side of thepanel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to befitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm +2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined togetherwith solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width isto be stuck on the interior side of the 'C' Channel using PVC solventadhesive etc. complete as per direction of Engineer -in-charge, manufacture'sspecification & drawing.30 mm thick plain PVC door shutters |
| 24 | Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 26 | For shutters of doors, windows & ventilators including providing and fixinghinges / pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paidfor separately)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 27 | Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 28 | Steel work for purlin/single section with G I pipes including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 29 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approvedsteel primer all complete. |
| 30 | Providing and fixing mild steel round holding down bolts with nuts and washer platescomplete. |
| 31 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 32 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 33 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm(+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns using self drilling/ self tapping screwscomplete:Ridges plain (500-600 mm) |
| 34 | Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work |
| 35 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) |
| 36 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mmSand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, includingflush pipe, manually controlled device (handle lever) conforming to IS : 7231, withall fittings and fixtures complete, including cutting and making good the walls andfloors wherever require:White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 37 | Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid |
| 38 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap |
| 39 | Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 453x357 mm |
| 40 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 41 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour600 mm long towel rail with total length of 645 mm, width 78 mm andeffective height of 88 mm, weighting not less than 190 gms |
| 42 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand)with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg)With Sewer bricks conforming to IS: 4885 |
| 43 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed workincluding cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 |
| 44 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2 |
| 45 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 25 mmdia 10 Kgf/cm2- External work - Exposed on wall |
| 46 | Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per directionof engineer in charge.110 mm dia 6Kgf/cm2 |
| 47 | Providing and fixing PVC pipes includings of pipes with one step PVC solventcement, trenching refilling & testing of joints complete as per direction ofEngineer in Charge. 63 mm dia 6Kgf/cm2 |
| 48 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 10 Kgf/cm2 - External work- Exposed on wall |
| 49 | Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in Charge.32 mm dia 10.Kgf/cm2 |
| 50 | Providing and fixing PVC moulded fittings/accessories for Rigid PVCpipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 51 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 52 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 53 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 54 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 55 | Supplying and fixing CP Health faucet good quality including cost of materials andlabour charges etc. complete as per the direction of site engineer-in-charge. |
| 56 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow |
| 57 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Bend |
| 58 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63x63x63 mm dia Door Tee |
| 59 | Providing and fixing trap of self cleansing design with screwed down or hingedgrating without vent arm complete, including cost of cutting and making good thewalls and floors:100 mm inlet and 100 mm outletSand Cast Iron S & S as per IS : 1729 |
| 60 | Providing and fixing uplasticised PVC connection pipe with brass unions:20 mmnominal bore |
| 61 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 62 | Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 63 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore |
| 64 | Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)<br> 4. 35 to 50 flush capacity Please Enable Macros to View BoQ information |