| Sl. No. | Item Description |
| 1 | Horizontal Expansion of Control Room Building at GAIL RT Pune (SIZE 7.5MX6.5M) |
| 2 | 1. CIVIL WORKS |
| 3 | A. DISMANTLING AND DEMOLISHING |
| 4 | Demolishing R.C.C. |
| 5 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 6 | Demolishing brick work |
| 7 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge |
| 8 | Dismantling C.I. or asbestos rain water pipe |
| 9 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 10 | Dismantling G.I. pipes (external work) |
| 11 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge |
| 12 | Taking out C.I. Cover |
| 13 | Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge |
| 14 | Dismantling old plaster or skirting raking out |
| 15 | Providing and applying 10 to 12mm dia hilti dowel bars including drilling, reinforcement & Hilti chemical et.c complete. |
| 16 | Dowel Bars |
| 17 | Providing and applying 10 to 12mm dia hilti dowel bars including drilling, reinforcement & Hilti chemical et.c complete. |
| 18 | Hydraulic Excavator/Backhoe |
| 19 | Supply & Operating of Hydraulic Excavator/Backhoe with Breaker Facility as per requirement along with Fuel and Operator |
| 20 | Tipper/Dumper |
| 21 | Providing Services of Tipper/Dumper including Driver, Helper & Diesel |
| 22 | B. EARTH WORK |
| 23 | Earth work in excavation upto 1.5m - Soil |
| 24 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil. |
| 25 | Earth work in excavation upto 1.5m - Ordinary rock |
| 26 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Ordinary rock |
| 27 | Filling available excavated earth |
| 28 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 29 | Filling of local earth |
| 30 | Excavating,spplying,stacking and filling of local earth ( including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift. |
| 31 | Supplying and filling in plinth |
| 32 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 33 | Supplying chemical emulsion |
| 34 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 35 | Anti termite treatment |
| 36 | Diluting and injecting chemical emulsion for post construction anti termite treatment - Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level : |
| 37 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 38 | C. CONCRETE WORK |
| 39 | PCC 1:3:6 |
| 40 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 41 | Plinth protection |
| 42 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 43 | D. R.C.C. WORK |
| 44 | RCC/RMC M25 - Plinth Level |
| 45 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) |
| 46 | All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum |
| 47 | RCC/RMC M25 - Upto V level |
| 48 | All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg/cum |
| 49 | Reinforcement |
| 50 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars |
| 51 | Centering and shuttering |
| 52 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 53 | Foundation, footing, bases of columns etc. for mass concrete |
| 54 | Suspended floors,roof,landing,balconies and access platform |
| 55 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 56 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 57 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 58 | Weather shade, Chajjas, corbels etc., including edges |
| 59 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 60 | E. BRICK WORK |
| 61 | Brick work CM 1:6 |
| 62 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 63 | Double scaffolding system (cup lock type) |
| 64 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock systemwith M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ orapplying chemical and removing it thereafter. The scaffolding systemshall be stiffened with bracings, runners, connecting with the building etc,wherever required, if feasible, for inspection of work at required locationswith essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for executionof all items for such works |
| 65 | F. STONE WORK |
| 66 | Granite work |
| 67 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, floors, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour, size and shade |
| 68 | Edge moulding of Granite work |
| 69 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 70 | Extra for fixing marble /granite stone |
| 71 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 72 | Extra for providing opening |
| 73 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 74 | G. Wood/uPVC/Aluminium Work |
| 75 | Wooden Frames of Door and Windows |
| 76 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length .Second class teak wood |
| 77 | WPC Door Frames |
| 78 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other rames/Chowkhat , calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 65 x 150 mm |
| 79 | WPC Door Shutter |
| 80 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) - 35 mm thick |
| 81 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3(ii) Sites with structure height more than 20m for all wind speeds |
| 82 | Fixed window / ventilator |
| 83 | Fixed window / ventilator with mullion / transom.Using R1 series with frame (33 mm & above ) x (35 mm & above) & mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre) |
| 84 | Casement Window |
| 85 | Casement Window with Double Rebate Frame with two Side Hung Glazed Panel on outside and two Side Hung wire mesh Panel on inside and French (False) Mullion with S.S. 304 friction hinges as per size and weight of sash, multipoint locking system, zinc alloy (zamak) powder coated handles with shoot bolt on both glazed and fly screen panel.Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & French (False) mullion (55 mm & above) x (60 mm& above) & metal grill (if required to be paid separately). (Height upto 1.8 metre). |
| 86 | 6 mm Clear Toughenend Glass |
| 87 | Supply & Fixing 6 mm Clear Toughenend Glass in Windows and Ventilators (weight not less than 12.50 kg/sqm). |
| 88 | Silicon filling |
| 89 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 90 | SS Fly Proof Wire |
| 91 | Providing and fixing fly proof Stainless steel wire gauge (Grade-304) , to windows, glazing, clerestory windows etc. using wire gauge with average width of aperture 1.4 mm in both directions and 0.50mm dia wire including fittings, consumables all complete. |
| 92 | Flush Door - 35mm thick |
| 93 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 94 | SS Handle |
| 95 | Providing and supplying a pair of stainless steel pull door handle (D or H Type-as per approval of EIC) having minimum length of 600 mm and dia 32 mm for door shutter. SS 304 brush finish of approved make. |
| 96 | SS Door Stopper |
| 97 | Providing and fixing SS door stopper ISI marked a transparent or dyed to required colour and shade with necessary screws etc. complete: |
| 98 | Hydraulic door closer |
| 99 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 100 | SS Tower Bolt - 250mm x10mm |
| 101 | Providing and fixing SSS finished SS 304 grade tower bolts of size 250mmx10mm |
| 102 | SS Tower Bolt - 150mm x10mm |
| 103 | Providing and fixing SSS finished SS 304 grade tower bolts of size 150mmx10mm |
| 104 | Mortice lock |
| 105 | Providing and fixing mortice latch and lock with 6 levers, SSS/SN finish, High Quality Zinc Alloy/Stainless Steel key etc. with necessary screws etc. complete. and a pair of lever handles |
| 106 | Door Stopper |
| 107 | Providing and fixing door stopper, SN finish High Quality Zinc Alloy/Stainless Steel, with necessary screws etc. complete |
| 108 | Roller Blind |
| 109 | Supplying and installing roller blinds of approved make, model and shade at all heights and location and required width and comprising of approved shade and quality fabric, 1 mm thick anodized extruded Aluminium alloy roller tube of approx. 38-mm O.D , a bidirectional operating Clutch mechanism designed for adjustment-free, slippage-free, crash proof smooth operation for all heights, high strength fiber glass reinforced polyester idler, powder coated steel Insert type brackets fitted with roller tube, round bottom rail, control unit engrooved with a Ball Pitch , Stainless Steel Ball Chain, and powder coated atomized steel installation brackets.Bottom rail along with the fabric shall be enclosed in a suitably created pocket and shall be of powder coated aluminium tube and closed from sides with end caps. The item includes all fittings, accessories, brackets, screws, anchor fasteners, fabric as per approved sample and shade all complete as per drawings, tender specifications, relevant standards and direction of Engineer in charge. (Height of blind from top bracket to bottom tube and width from bracket to bracket shall be measured for payment) |
| 110 | GI Partitions |
| 111 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board,including providing and fixing of frame work made of special section power pressed/ rollform G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor andceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to thefloor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diameter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and thestuds 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thickfixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mmcentre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends ofpartition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs atspacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete. 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certificationmarks) |
| 112 | GI Panelling |
| 113 | Providing and fixing, in position concealed G.I. section for wall paneling using board ofrequired thickness fixed on the ‘W’ profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the ‘W’ profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. Tapered edge calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with compressive strength 225 kg/ sq.cm, Bending strength 100 kg/sq.cm. 10mm thick |
| 114 | Glass Partitions |
| 115 | Providing and fixing FRAMELESS GLASS INTERNAL PARTITIONS forming a cabin with 12 mm thick clear toughened glass with division as per approved drawing and height as per elevation drawings. With approved make S.S. fittings of S.S.-316 grade . All the glass shall be fixed with S.S. fittings to the adjoining memebers/ Glass/ Brick/ RCC with fixing clips including filling up necessary gaps at junction, top, bottom and sides with required weather silicon sealant. The complete installation of glazing shall be as per drawings or as directed by Engineer- in- charge and as per the site conditions. Minimum two rows of spider to be provided to every vertical support The installation of glass partition with stainless steel fixtures shall be as per drawings along with approved grade of silicon sealant of \\"Dow corning - USA\\" or \\"WACKER - Germany\\". The partition shall be aligned for the entire height and for the entire width by laser beam equipment to ensure 100 percent 'X' axis and 'Y' axis alignment. The complete design fixing details, spider fittings, details/ design will be done as per approval of Engineer-in charge. (The work is to be got executed by approved specialized agency approved by Engineer in charge.) |
| 116 | Glass Door |
| 117 | Providing, fixing and erecting at site frameless glass pivoted door consisting of diecast patch fitting (SS grade 316) with stainless steel cover and corner lock with euro profile cylinder. The fittings will be mounted on 12 mm toughened glass door with all necessary required accessories. The door will also consist of floor spring BTS-84 with all necessary glass mounting accessories for the self closing feature complete including the cost of 12 mm thick clear toughened glass. Single door with side and upper panels (Consisting of over and side panels 1 no, connector for side /upper panel 1 no, Upper patch 1 no, Bottom patch 1 no, Floor Lock with cylinder 1 no, Strike plate 1 no and pair of Pull handle - D Handles of 450 mm. Cost of floor spring to be paid in relevant item separately |
| 118 | Hydraulic floor spring |
| 119 | Placing the double action hydraulic floor spring with new floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors if required, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate, including dismantling and refitting the door and disposalof existing damaged floor spring and any other related works etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate |
| 120 | Glass Film |
| 121 | Providing and fixing Glass film of approved make and design (frosted, etc.) over the existing glass complete as per Architectural Drawings and direction of Engineer - in - charge |
| 122 | Storage cabinet |
| 123 | Providing and fixing in position of box type STORAGE CABINET unit made out of 18 mm thick termite-resistant, waterproof BWP commercial ply for bottom & top, shelf/ partition, sides, drawer units, shelves etc. and 12 mm WPC back sheet for backing. Front shutter made out of 18mm thick commercial board, all outer exposed area shall be finished with approved 1mm laminate and inside areas shall be finished with 1 mm thick laminate as/approved. Anti-termite oil to be put on the raw surface before applying/ finishing with laminate. Price to including necessary hardware such as knobs, handles, magnet catchers, lock, piano hinges, hanging rod oval shaped, telescopic channel for drawers. All exposed edges finished with PVC lipping (2mm) duly finished with matching colour and pattern as directed. Complete in all respect including grove, fixing with wall, getting it approved, constructing set (s) for mock-up sample for approval, modifying, etc. 450 to 600mm deep average all complete as per tender drawing. Note: The front finished plan area of the cabinet shall be measured for payment purpose. (Makes: For Plywood & Laminates: Century/Archid/Green/Merino) (Makes SS Fittings: Hettich/Godrej/Hafele/Ozone) |
| 124 | 18 mm thick plywood |
| 125 | Providing and Fixing plywood as required including cutting to required size, complete as per direction of EIC- 18 mm thick commercial plywood (MR grade plywood confirming IS:303 ) of approved make. |
| 126 | 12 mm thick plywood |
| 127 | Providing and Fixing plywood as required including cutting to required size, complete as per direction of EIC- 12 mm thick commercial plywood (MR grade plywood confirming IS:303 ) of approved make. |
| 128 | 1.5mm thick Laminated |
| 129 | Providing & Fixing decorative high pressure laminated sheet of minimum 1.5 mm thickness of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesivebonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 130 | Veneer |
| 131 | Providing and supplying plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with :Decorative veneer facings of approved manufacture. |
| 132 | Lipping |
| 133 | Providing and fixing teak wood lipping of size 25x3 mm in pelmet. |
| 134 | Rockwool acoustic Insulation |
| 135 | Providing and supplying of Rockwool acoustic Insulation panel for cubical and cabin construction purposes of 100mm thickness with necessaary arrangements as per direction of EIC |
| 136 | H. FLOORING |
| 137 | Ceramic glazed wall tiles 300x300 |
| 138 | Providing and laying rectified glazed Ist quality ceramic glazed wall tiles 300x300 mm or more conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except white,ivory,grey,fume red brown of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 20 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. for dado |
| 139 | Vitrified floor Tile 1200 x 1200 |
| 140 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & mfg, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. for flooring.The tiles must be cut with zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel,piller,wedge,chips of required thickness,levelling system & rubber mallet for placing the tiles gently & easily. Size of Tile 1200x1200 mm for flooring MATT/Antiskid |
| 141 | Ceramic floor tiles 300x 300 |
| 142 | Providing and laying rectified Anti Skid Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. For Flooring |
| 143 | Vitrified floor Tile 600 x 600 |
| 144 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacture in all colours and shede in skirting,riser of steps,laid with cement based high polymer modified quick set tile adhesive ( water based )confirming to IS 15477 in average 6mm thickness including grouting of joints ( payment for grouting of joints to be made separately ). Size of Tile 600x600 mm |
| 145 | Grouting the joints of flooring/wall tiles |
| 146 | Grouting the joints of flooring/wall tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm |
| 147 | POLISHING ON MARBLE/GRANITE |
| 148 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete |
| 149 | I. ROOFING |
| 150 | PVC Rain water Pipe |
| 151 | Rain water unplasticised rigid PVC rain water pipe 110 mm long with all necessary material like screws, washers etc., |
| 152 | False ceiling Gypsum Board |
| 153 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with |
| 154 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 155 | Tiled false ceiling |
| 156 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. GI Metal ceiling Lay in perforated Tegular edge global white color tiles of sie 595x595mm |
| 157 | J. FINISHING |
| 158 | 15 mm Cement Plaster |
| 159 | 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side ofsingle or half brick wall |
| 160 | 18 mm cement plaster |
| 161 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge |
| 162 | Mixing water proofing material |
| 163 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. ( Each means here is per bag of 50kg cement used in the mix) |
| 164 | GI hexagonal chicken wire mesh |
| 165 | Providing and fixing GI hexagonal chicken wire mesh of size 12mm x22g or as required at the junction of dissimilar surfaces of brick masonry wall and R C C column by beams or as required including necessary nails for fixing etc, complete all as per specification and direction of Engineer -in -charge for all floor at all heights. |
| 166 | Primer |
| 167 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surfacehaving VOC content less than 50 grams/litre |
| 168 | CEMENT PUTTY 2MM |
| 169 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 170 | Gypsum lightweight plaster |
| 171 | Providing and applying 12mm thick (average) premixed formulated one coat of gypsum lightweight plaster having additives & light weight aggregates as vermiculite/pertile respectively conforming to IS:2547(Part-I & II) 1976 ,applied on hacked/uneven background such as bare brick/block/RCC work on walls & ceiling at all floors & locations,finished in smooth line & level etc. complete |
| 172 | Acrylic emulsion paint |
| 173 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.TWO COATS |
| 174 | Exterior Paint with Silicone Additives |
| 175 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 176 | Synthetic enamel paint |
| 177 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 178 | FRENCH SPIRIT POLISH |
| 179 | Providing & Applying French spirit polishing :One or more coats on old/new work |
| 180 | K. PLUMBING WORKS |
| 181 | I. SANITARY FIXTURE |
| 182 | Wall mounting Water closet |
| 183 | Providing and supplying white vitreous china wall mount l type water closet (European type) with seat and lid with C.P. brass hinges and rubber buffers, with fittings.: W.C. pan with white solid plastic seat and lid. (Make : jaquar or hindware or Essco or Parryware) - Rimless Blind Installation Wall Hung WC Size: 380x525x375 mm - (Model No: KUS-WHT-35953BIUFSMPM) |
| 184 | Under Counter Basin |
| 185 | Providing and fixing first quality white vitreous china Under Counter Basin with Fixing Accessories Size: 605x430x200 Mm shape: Oval basin for under counter mounting, specially fabricated CI / MS brackets, painted with two or three coats of enamel paint of approved shade over a coat of primer, waste coupling, 32 mm CP brass waste and CP brass cast bottle trap and pipe to wall with CP brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required. (JAQUAR Cat No - CNS-WHT-705 or equivalent) with waste pipe, waste coupling wtc., |
| 186 | URINAL |
| 187 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 188 | URINALS PRESS COCK |
| 189 | Providing & Supplying of Urinal press Cock/valve with Auto Closing System including Wall Flange of approved make and model. |
| 190 | Long Body Bib Cock with Wall Flange |
| 191 | Providing and fixing Long Body Bib Cock with Wall Flange of approved quality conforming to IS:8931 :15 mm nominal bore ( Jaquar model : COP-CHR-107NPM) |
| 192 | C.P. brass angle valve |
| 193 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore (Jaquar model no: OPP-SSF-15053PM) |
| 194 | Toilet Paper Holder |
| 195 | Providing and fixing SS steel toilet paper holder with flap of approved quality: (JAQUAR Model No - ACN-CHR-1151N OR Equivalent as per approved vendor list) |
| 196 | Beveled edge mirror of superior glass |
| 197 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 198 | SS Towel rail |
| 199 | Providing and fixing SS towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (Jaquar model no: CPA-CHR-1111) |
| 200 | CP brass Health faucet |
| 201 | Providing and fixing of CP brass Health faucet with 8mm dia 1mtr. Long PVC tube and wall hook fixed to wall with rawl plug and CP brass screws complete. (Make: Jaquar Cat. No.(ALD-CHR-573) or equivalent make as approved by Engineer-in-Charge) |
| 202 | Long connecting hose |
| 203 | Prividing and Fixing 1.5 feet long connecting hose with nuts at both ends complete.(Make: Jaquar Cat.No.(ALD-CHR-805B) or equivalent make as approved by Engineer-in-Charge) for health faucet |
| 204 | Kitchen sink with drain board |
| 205 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm along with waste pipe, waste coupling wtc., |
| 206 | Sink Cock |
| 207 | Providing and fixing J shaped Sink Cock (Jaquar make:ARI-CHR-39347S) or equivalent make as approved by Engineer-in-Charge) |
| 208 | Bib Cock |
| 209 | Providing and supplying C.P. Brass bib cock with flange and with or without nozzle of approved quality conforming to IS : 8931- 15 mm Nominal bore |
| 210 | II. WATER SUPPLY INTERNAL |
| 211 | CPVC Pipes - Concealed work |
| 212 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVCsolvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 213 | 15 mm nominal dia Pipes |
| 214 | 20 mm nominal dia Pipes |
| 215 | 25 mm nominal dia Pipes |
| 216 | CPVC Pipes - Internal work - Exposed on wall |
| 217 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & |
| 218 | 25 mm nominal dia Pipes |
| 219 | 32 mm nominal dia Pipes |
| 220 | 40 mm nominal dia Pipes |
| 221 | 50 mm nominal dia Pipes |
| 222 | Gun metal gate valve |
| 223 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 224 | 25 mm nominal bore |
| 225 | 32 mm nominal bore. |
| 226 | 40 mm nominal bore |
| 227 | 50 mm nominal bore |
| 228 | Ball valve (brass) |
| 229 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 230 | 20 mm nominal bore |
| 231 | 25 mm nominal bore |
| 232 | Water storage tank |
| 233 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support |
| 234 | III. SOIL, WASTE, VENT & RAIN WATER PIPES |
| 235 | uPVC SWR floor trap |
| 236 | Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper co |
| 237 | uPVC SWR Pipes- Rain water pipes - 160mm Dia |
| 238 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For Rain water pipes). Nothing extra will be paid fo |
| 239 | Soil & waste pipes -110mm Dia |
| 240 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid - 110mm diameter |
| 241 | Soil & waste pipes -75mm Dia |
| 242 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid- 75mm diameter |
| 243 | PVC Pipe - 40mm Dia |
| 244 | Providing, laying and fixing P.V.C. pipe of ---- dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Inside Toilets).Make: Astral, Ashirvad & Prince 40 mm outer dia |
| 245 | Cowl dome UPVC - 110mm Dia |
| 246 | Providing and Fixing in position UPVC ultra violet stabilized 110mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete.Make: Astral, Ashirvad & Prince |
| 247 | Cowl dome UPVC - 75mm Dia |
| 248 | Providing and Fixing in position UPVC ultra violet stabilized 75mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete. Make: Astral, Ashirvad & Prince |
| 249 | 150 mm dia. R.C.C. pipe |
| 250 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 251 | 150 mm dia. R.C.C. pipe |
| 252 | Masonry manhole |
| 253 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 co Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885 |
| 254 | Extra Depth for manhole |
| 255 | Extra for depth for manholes : Size 90x80 cm With Sewer bricks conforming to IS : 4885 |
| 256 | S.W. gully trap |
| 257 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than4.50 kg and frame to be not less tha 150 x 100 mm size P type With sewer bricks conforming to IS : 4885 |
| 258 | Soak Pit |
| 259 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW. drain 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks. |
| 260 | Honey comb brick work |
| 261 | Honey-comb brick work 10 / 11.4 cm thick with common burnt clay bricks at all levels with cement mortar 1:4 (1 cement : 4 coarse sand). |
| 262 | Brick bats for soak pit |
| 263 | Supply & filling of broken brick bats and filling into soak pit of size 120 mm to 40 mm. |
| 264 | Precast RCC perforated drain covers |
| 265 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineering-charge. |
| 266 | L. Waterproofing works |
| 267 | Brick Bat Coba Waterproofing |
| 268 | Providing and laying integral cement based water proofing including preparation of surface as required consisting of following operation(a) applying a slurry coat of neat cement using 2.75kg/sqm of cement admixture with water proofing compound or approved by EIC (b) Laying of brick bats in cement mortar 1:5 admixed with waterproofing compound over 20 mm thick layer of cement mortar (c) after two days of curing apply 2nd coat of cement coat of slurry using 2.75kg/sqm with waterproofing compound (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1 : 4 with water proofing compound including (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 269 | 52 mm thick cement concrete flooring |
| 270 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 271 | Smart Care Damp Proof Works |
| 272 | Supplying and Applying Asian smart care Damp proof advance or Equivalent as per list of makes of self primer at 30 % dilution and forced coverage of 10 Sq.Ft./Ltr. on horizontal surface and 25 Sq.Ft/L on vertical surface. Laying layer of Fibre glass cloth when the primer layer is still green/wet. Overlaps of joints of fibre cloth should not be less than 10 cm. After drying apply first coats of Smart Care Damp Proof without any dilution at forced coverage of 25 Sq.Ft./Ltr. After drying apply Final coats of Smart Care Damp Proof without any dilution at forced coverage of 25 Sq.Ft./Ltr. Scope include cleaning of existing surface with a solution of bleaching powder. |
| 273 | 2. ELECTRICAL, CCTV, BIS WORKS |
| 274 | A. SUB-HEAD-I: CIRCUIT POINT WIRING |
| 275 | Primary point |
| 276 | Wiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 277 | Group-C (Primary point ) |
| 278 | Looping Point |
| 279 | Wiring for group controlled (looping) light point /fan point / exhaust fan point/call bell point (without independent switch etc) with 1.5 sqmm FRLS PVC insulated copper conductor cable in surface/recessed PVC conduit and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc.as required. |
| 280 | Group-C (looping point ) |
| 281 | Twin control light point |
| 282 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 283 | GI box along with modular base & cover plate |
| 284 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 285 | 1 or 2 Module |
| 286 | 3 Module |
| 287 | 4 Module |
| 288 | 6 Module |
| 289 | 8 Module |
| 290 | 12 Module |
| 291 | Modular base & cover plate |
| 292 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 293 | 1 or 2 Module |
| 294 | 3 Module |
| 295 | 4 Module |
| 296 | 6 Module |
| 297 | 8 Module |
| 298 | 12 Module |
| 299 | Modular switch/ socket |
| 300 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 301 | 5/6 A switch |
| 302 | 2 way 5/6 A switch |
| 303 | 15/16 A switch |
| 304 | 3 pin 5/6 A socket outlet |
| 305 | 6 pin 15/16 A socket outlet |
| 306 | Modular Blanking Plate |
| 307 | Supplying & Fixing Modular Blanking Plate on the existing modular plate & switch box excluding modular plate as required |
| 308 | Wiring for circuit |
| 309 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 310 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 311 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 312 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 313 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 314 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 315 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 316 | B. SUB-HEAD-II: CABLE TRAYS AND ACCESSORIES : |
| 317 | Galvanised Iron cable tray |
| 318 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ wall with G.I. suspenders including G.I. bolts & nuts, etc. as required to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers, supporting arrangements etc as per drawings/site condition and as required. |
| 319 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 320 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 321 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 322 | Bends |
| 323 | Supplying and installing following size of perforated pre-painted M.S cable trays bends with cover and with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required. |
| 324 | 100 mm width X 50 mm depth X 1.6mm thickness |
| 325 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 326 | Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with cover and with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required. |
| 327 | 100 mm width X 50 mm depth X 1.6mm thickness |
| 328 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 329 | C. SUB-HEAD-III: DISTRIBUTION BOARDS |
| 330 | MCB Board - 415V |
| 331 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 332 | 4 way (4 + 12), Double door |
| 333 | 8 way (4 + 24), Double door |
| 334 | MCB Board - 240V |
| 335 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 336 | 4/6 way (4 + 12), Double door |
| 337 | 8 way (4 + 24), Double door |
| 338 | MCB DB Board - 240V |
| 339 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 340 | 40 amps |
| 341 | 63 amps |
| 342 | C” curve, miniature circuit breaker |
| 343 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 344 | Single pole |
| 345 | Double pole |
| 346 | Triple pole |
| 347 | Triple pole and neutral |
| 348 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 349 | MCB DB |
| 350 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 351 | 63 amps |
| 352 | 100 amps |
| 353 | Single Pole Blanking Plate |
| 354 | Supplying and fixing Single Pole Blanking Plate in the existing MCB DB complete Etc. as required. |
| 355 | D. SUB-HEAD-IV: EARTHING INSTALLATION |
| 356 | Earthing |
| 357 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 358 | G.I. earth plate 600 mm X 600 mm X 6 mm thick |
| 359 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe 2.7 M long etc. with charcoal/ coke and salt as required. |
| 360 | 25 mm X 5 mm G.I. strip |
| 361 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 362 | 6 SWG dia G.I. wire |
| 363 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 364 | E. SUB-HEAD-VI: LIGHTS ITEMS |
| 365 | RECESS MOUNTED LED LIGHT |
| 366 | Supply, fixing, testing and commissioning of 35W/36W 2X2 Feet RECESS MOUNTED LED LIGHT (Correlated Colour Temperature (Nom) 6500 K, THD < 10%, PF >= 0.9 all accessories as required. (Philips Model no: RC380B LED42S-6500 G6 L60W60 PSU OD S1. OR Equivalent as per approved vendor list) |
| 367 | 40 W LED CEILING/ WALL MOUNTED TUBE LIGHT |
| 368 | SITC of 40 W LED CEILING/ WALL MOUNTED TUBE LIGHT with all accessories as required. (4 feet). Colour Temperature - 6500K, 100lm/W . Philips Star Bright Decorative Modern Product SKU : 919615898138 OR Equivalent as per approved vendor list |
| 369 | LED bulk head fitting |
| 370 | SITC LED bulk head fitting 10 watt IP 65 & IK 08 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable. |
| 371 | LED Panel light/ Down light |
| 372 | SITC of 9W/10W LED Panel light/ Down light recessed with all accessories as required. Colour Temperature - 6500K, PF > 0.9. Philips DN295B LED10S-6500 PSE WH S2 OR Equivalent as per approved vendor list |
| 373 | HDPE Pipe 32mm |
| 374 | High density poly ethylene pipes 32mm (HDPE) of pressure rating 6 kgf/cm2 laid in trenches |
| 375 | Exhaust Fan 200 mm |
| 376 | SITC of Exhaust Fan 200 mm Sweep area [ 240V , 1200-1500 RPM , 3 BLADES ] with Lovers |
| 377 | LED square / circular Max. 18 W down lighter/ Panel Light |
| 378 | Supplying and erecting rimless full glow LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 379 | Wall mount fan |
| 380 | Providing & Fixing with connection, high speed wall mount fan of 400 mm of approved make and shade as per the directives of EIC. |
| 381 | F. SUB-HEAD-VIII: CONDUIT,CCTV BIS ETC. |
| 382 | PVC Conduit |
| 383 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 384 | Modular switch/ socket |
| 385 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections, termination, crimping with cable. |
| 386 | RJ 45 female jack / Sockets for Data / Voice outlet |
| 387 | UTP 4 pair CAT 6 LAN |
| 388 | Supplying and drawing of UTP 4 pair CAT 6 LAN, 23 AWG ARMOURED Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 389 | 3. FIRE FIGHTINGS |
| 390 | Photothermal detector |
| 391 | Supplying, installing, testing and commissioning of intelligent analog adressable photothermal detector complete with mounting base complete as required. |
| 392 | Fire alarm armoured cable |
| 393 | Supplying & laying of 2x1.5 spmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 394 | Addressable manual call point |
| 395 | Supplying, installing, testing and commissioning of adressable manual call point complete as required. |
| 396 | Adressable horn cum strobe |
| 397 | Supplying, installing, testing and commissioning of adressable horn cum strobe complete as required. |
| 398 | Smoke detector |
| 399 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connection etc. as required |
| 400 | Fire survival armoured cable |
| 401 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 2 x 1.5 sq.mm |
| 402 | MS flexible pipe |
| 403 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 404 | 4. AC WORKS |
| 405 | CASSETTE AC |
| 406 | Supply, installation, testing, and commissioning of 02 Ton TR CASSETTE AC system (05 star rating, inverter type) complete with copper condenser and all standard accessories. The unit shall be energy-efficient, equipped with 100% copper piping and condenser coil, and suitable for continuous operation under Indian climatic conditions. The installation scope includes indoor and outdoor units, mounting frames, vibration pads, interconnecting copper refrigerant piping, electrical wiring, drainage piping, gas charging for making the system fully functional. (Including the ceiling anchoring and its neccessary arrangements) |
| 407 | Split AC |
| 408 | Supply,installation,testing and commissioning of following BEE 5 Star rated (2 TON), Inverter Split AC with indoor & outdoor unit and all accessories as per specifications etc. as required including, required outdoor unit frame, core cutting for refringent piping and cable, PVC drain pipe, stands etc. |
| 409 | Copper pipe |
| 410 | Supplying, fixing , jointing , testing commissioning of additional required (in addition to supplied copper piping with the AC unit) Interconnecting refrigerant copper pipe work suitable for R-32/R- 410A refrigerant with (9mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor &outdoor units as per specifications for Split AC System including all fixing & routing accessories and are in pair. |
| 411 | Supply, Installation, Testing & Commissioning of the copper conductor, FRLS, PVC insulated, 1.1kV control cum Transmission wiring in existing surface/recessed steel/pvc conduits between indoor & outdoor units including supply of screened wires, supports, installation, saddles, ties, tags, ferrules, lugs, nuts/bolts/hardware etc. complete in all respects as per specifications and any other item required to make the system complete. 4Cx 6 Sqmm copper |
| 412 | Drain Pipe |
| 413 | DRAIN PIPING Extra Providing and fixing in position the following pipes cut to required lengths and necessary fitting with 9 mm thk.Nitrile Rubber Insulation as per drawing |
| 414 | Power Cable |
| 415 | Extra Power Cable for IDU (2.5sqmm 3 core flexible Cable). |
| 416 | Vertical Expansion of Control Room Building at Dabhol for GAIL |
| 417 | 1. CIVIL WORKS |
| 418 | A. DISMANTLING AND DEMOLISHING |
| 419 | Demolishing R.C.C. |
| 420 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 421 | Demolishing brick work |
| 422 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge |
| 423 | Dismantling doors, windows |
| 424 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :15.12 |
| 425 | b) Of area Beyond 3.00sqm |
| 426 | Dismantling tile |
| 427 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 428 | Dismantling C.I. or asbestos rain water pipe |
| 429 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 430 | Dismantling G.I. pipes (external work) |
| 431 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge |
| 432 | Taking out C.I. Cover |
| 433 | Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge |
| 434 | Dismantling of flushing cistern |
| 435 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 436 | Dismantling old plaster or skirting raking out |
| 437 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 438 | Dismantling of Waterproofing |
| 439 | Dismantling of Existing waterproofing manually / by mechanical means and disposal of material outside the premises as per direction of Engineer-in-charge(brick bat coba/ app membrane or both). |
| 440 | Dowel Bars |
| 441 | Providing and applying 10 to 12mm dia hilti dowel bars including drilling, reinforcement & Hilti chemical et.c complete. |
| 442 | Hydraulic Excavator/Backhoe |
| 443 | Supply & Operating of Hydraulic Excavator/Backhoe with Breaker Facility as per requirement along with Fuel and Operator |
| 444 | Tipper/Dumper |
| 445 | Providing Services of Tipper/Dumper including Driver, Helper & Diesel |
| 446 | B. EARTH WORK |
| 447 | Surface dressing |
| 448 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil. |
| 449 | Earth work in excavation upto 1.5m - Soil |
| 450 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil. |
| 451 | Earth work in excavation upto 1.5m - Ordinary rock |
| 452 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Ordinary rock |
| 453 | Filling available excavated earth |
| 454 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 455 | Filling of local earth |
| 456 | Excavating,spplying,stacking and filling of local earth ( including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift. |
| 457 | Supplying and filling in plinth |
| 458 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 459 | Supplying chemical emulsion |
| 460 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 461 | Anti termite treatment |
| 462 | Diluting and injecting chemical emulsion for post construction anti termite treatment - Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level : |
| 463 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 464 | C. CONCRETE WORK |
| 465 | PCC 1:3:6 |
| 466 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 467 | Plinth protection |
| 468 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 469 | D. R.C.C. WORK |
| 470 | RCC/RMC M25 - Plinth Level |
| 471 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) |
| 472 | All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum |
| 473 | RCC/RMC M25 - Upto V level |
| 474 | All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg/cum |
| 475 | Reinforcement |
| 476 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars |
| 477 | Centering and shuttering |
| 478 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 479 | Foundation, footing, bases of columns etc. for mass concrete |
| 480 | Suspended floors,roof,landing,balconies and access platform |
| 481 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 482 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 483 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 484 | Weather shade, Chajjas, corbels etc., including edges |
| 485 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 486 | E. BRICK WORK |
| 487 | Brick work CM 1:6 |
| 488 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 489 | AAC Block |
| 490 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 100/125/150mm to 300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). |
| 491 | Double scaffolding system (cup lock type) |
| 492 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock systemwith M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ orapplying chemical and removing it thereafter. The scaffolding systemshall be stiffened with bracings, runners, connecting with the building etc,wherever required, if feasible, for inspection of work at required locationswith essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for executionof all items for such works |
| 493 | F. STONE WORK |
| 494 | Granite work |
| 495 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, floors, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour, size and shade |
| 496 | Edge moulding of Granite work |
| 497 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 498 | Extra for fixing marble /granite stone |
| 499 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 500 | Extra for providing opening |
| 501 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 502 | G. Wood/uPVC/Aluminium Work |
| 503 | Wooden Frames of Door and Windows |
| 504 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length .Second class teak wood |
| 505 | WPC Door Frames |
| 506 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other rames/Chowkhat , calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 65 x 150 mm |
| 507 | WPC Door Shutter |
| 508 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) - 35 mm thick |
| 509 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3(ii) Sites with structure height more than 20m for all wind speeds |
| 510 | Fixed window / ventilator |
| 511 | Fixed window / ventilator with mullion / transom.Using R1 series with frame (33 mm & above ) x (35 mm & above) & mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre) |
| 512 | Casement Window |
| 513 | Casement Window with Double Rebate Frame with two Side Hung Glazed Panel on outside and two Side Hung wire mesh Panel on inside and French (False) Mullion with S.S. 304 friction hinges as per size and weight of sash, multipoint locking system, zinc alloy (zamak) powder coated handles with shoot bolt on both glazed and fly screen panel.Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & French (False) mullion (55 mm & above) x (60 mm& above) & metal grill (if required to be paid separately). (Height upto 1.8 metre). |
| 514 | 6 mm Clear Toughenend Glass |
| 515 | Supply & Fixing 6 mm Clear Toughenend Glass in Windows and Ventilators (weight not less than 12.50 kg/sqm). |
| 516 | Silicon filling |
| 517 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 518 | SS Fly Proof Wire |
| 519 | Providing and fixing fly proof Stainless steel wire gauge (Grade-304) , to windows, glazing, clerestory windows etc. using wire gauge with average width of aperture 1.4 mm in both directions and 0.50mm dia wire including fittings, consumables all complete. |
| 520 | Flush Door - 35mm thick |
| 521 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 522 | SS Handle |
| 523 | Providing and supplying a pair of stainless steel pull door handle (D or H Type-as per approval of EIC) having minimum length of 600 mm and dia 32 mm for door shutter. SS 304 brush finish of approved make. |
| 524 | SS Door Stopper |
| 525 | Providing and fixing SS door stopper ISI marked a transparent or dyed to required colour and shade with necessary screws etc. complete: |
| 526 | Hydraulic door closer |
| 527 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 528 | SS Tower Bolt - 250mm x10mm |
| 529 | Providing and fixing SSS finished SS 304 grade tower bolts of size 250mmx10mm |
| 530 | SS Tower Bolt - 150mm x10mm |
| 531 | Providing and fixing SSS finished SS 304 grade tower bolts of size 150mmx10mm |
| 532 | Mortice lock |
| 533 | Providing and fixing mortice latch and lock with 6 levers, SSS/SN finish, High Quality Zinc Alloy/Stainless Steel key etc. with necessary screws etc. complete. and a pair of lever handles |
| 534 | Door Stopper |
| 535 | Providing and fixing door stopper, SN finish High Quality Zinc Alloy/Stainless Steel, with necessary screws etc. complete |
| 536 | Roller Blind |
| 537 | Supplying and installing roller blinds of approved make, model and shade at all heights and location and required width and comprising of approved shade and quality fabric, 1 mm thick anodized extruded Aluminium alloy roller tube of approx. 38-mm O.D , a bidirectional operating Clutch mechanism designed for adjustment-free, slippage-free, crash proof smooth operation for all heights, high strength fiber glass reinforced polyester idler, powder coated steel Insert type brackets fitted with roller tube, round bottom rail, control unit engrooved with a Ball Pitch , Stainless Steel Ball Chain, and powder coated atomized steel installation brackets.Bottom rail along with the fabric shall be enclosed in a suitably created pocket and shall be of powder coated aluminium tube and closed from sides with end caps. The item includes all fittings, accessories, brackets, screws, anchor fasteners, fabric as per approved sample and shade all complete as per drawings, tender specifications, relevant standards and direction of Engineer in charge. (Height of blind from top bracket to bottom tube and width from bracket to bracket shall be measured for payment) |
| 538 | GI Partitions |
| 539 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diameter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete. 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) |
| 540 | GI Panelling |
| 541 | Providing and fixing FRAMELESS GLASS INTERNAL PARTITIONS forming a cabin with 12 mm thick clear toughened glass with division as per approved drawing and height as per elevation drawings. With approved make S.S. fittings of S.S.-316 grade . All the glass shall be fixed with S.S. fittings to the adjoining memebers/ Glass/ Brick/ RCC with fixing clips including filling up necessary gaps at junction, top, bottom and sides with required weather silicon sealant. The complete installation of glazing shall be as per drawings or as directed by Engineer- in- charge and as per the site conditions. Minimum two rows of spider to be provided to every vertical support The installation of glass partition with stainless steel fixtures shall be as per drawings along with approved grade of silicon sealant of \\"Dow corning - USA\\" or \\"WACKER - Germany\\". The partition shall be aligned for the entire height and for the entire width by laser beam equipment to ensure 100 percent 'X' axis and 'Y' axis alignment. The complete design fixing details, spider fittings, details/ design will be done as per approval of Engineer-in charge. (The work is to be got executed by approved specialized agency approved by Engineer in charge.) |
| 542 | Glass Partitions |
| 543 | Providing and fixing FRAMELESS GLASS INTERNAL PARTITIONS forming a cabin with 12 mm thick clear toughened glass with division as per approved drawing and height as per elevation drawings. With approved make S.S. fittings of S.S.-316 grade . All the glass shall be fixed with S.S. fittings to the adjoining memebers/ Glass/ Brick/ RCC with fixing clips including filling up necessary gaps at junction, top, bottom and sides with required weather silicon sealant. The complete installation of glazing shall be as per drawings or as directed by Engineer- in- charge and as per the site conditions. Minimum two rows of spider to be provided to every vertical support The installation of glass partition with stainless steel fixtures shall be as per drawings along with approved grade of silicon sealant of \\"Dow corning - USA\\" or \\"WACKER - Germany\\". The partition shall be aligned for the entire height and for the entire width by laser beam equipment to ensure 100 percent 'X' axis and 'Y' axis alignment. The complete design fixing details, spider fittings, details/ design will be done as per approval of Engineer-in charge. (The work is to be got executed by approved specialized agency approved by Engineer in charge.) |
| 544 | Glass Door |
| 545 | Providing, fixing and erecting at site frameless glass pivoted door consisting of diecast patch fitting (SS grade 316) with stainless steel cover and corner lock with euro profile cylinder. The fittings will be mounted on 12 mm toughened glass door with all necessary required accessories. The door will also consist of floor spring BTS-84 with all necessary glass mounting accessories for the self closing feature complete including the cost of 12 mm thick clear toughened glass. Single door with side and upper panels (Consisting of over and side panels 1 no, connector for side /upper panel 1 no, Upper patch 1 no, Bottom patch 1 no, Floor Lock with cylinder 1 no, Strike plate 1 no and pair of Pull handle - D Handles of 450 mm. Cost of floor spring to be paid in relevant item separately |
| 546 | Hydraulic floor spring |
| 547 | Placing the double action hydraulic floor spring with new floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors if required, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate, including dismantling and refitting the door and disposalof existing damaged floor spring and any other related works etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate |
| 548 | Glass Film |
| 549 | Providing and fixing Glass film of approved make and design (frosted, etc.) over the existing glass complete as per Architectural Drawings and direction of Engineer - in - charge |
| 550 | Storage cabinet |
| 551 | Providing and fixing in position of box type STORAGE CABINET unit made out of 18 mm thick termite-resistant, waterproof BWP commercial ply for bottom & top, shelf/ partition, sides, drawer units, shelves etc. and 12 mm WPC back sheet for backing. Front shutter made out of 18mm thick commercial board, all outer exposed area shall be finished with approved 1mm laminate and inside areas shall be finished with 1 mm thick laminate as/approved. Anti-termite oil to be put on the raw surface before applying/ finishing with laminate. Price to including necessary hardware such as knobs, handles, magnet catchers, lock, piano hinges, hanging rod oval shaped, telescopic channel for drawers. All exposed edges finished with PVC lipping (2mm) duly finished with matching colour and pattern as directed. Complete in all respect including grove, fixing with wall, getting it approved, constructing set (s) for mock-up sample for approval, modifying, etc. 450 to 600mm deep average all complete as per tender drawing. Note: The front finished plan area of the cabinet shall be measured for payment purpose. (Makes: For Plywood & Laminates: Century/Archid/Green/Merino) (Makes SS Fittings: Hettich/Godrej/Hafele/Ozone) |
| 552 | 18 mm thick plywood |
| 553 | Providing and Fixing plywood as required including cutting to required size, complete as per direction of EIC- 18 mm thick commercial plywood (MR grade plywood confirming IS:303 ) of approved make. |
| 554 | 12 mm thick plywood |
| 555 | Providing and Fixing plywood as required including cutting to required size, complete as per direction of EIC- 12 mm thick commercial plywood (MR grade plywood confirming IS:303 ) of approved make. |
| 556 | 1.5mm thick Laminated |
| 557 | Providing & Fixing decorative high pressure laminated sheet of minimum 1 mm thickness of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesivebonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 558 | Veneer |
| 559 | Providing and supplying plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with :Decorative veneer facings of approved manufacture. |
| 560 | Lipping |
| 561 | Providing and fixing teak wood lipping of size 25x3 mm in pelmet. |
| 562 | Rockwool acoustic Insulation |
| 563 | Providing and supplying of Rockwool acoustic Insulation panel for cubical and cabin construction purposes of 100mm thickness with necessaary arrangements as per direction of EIC |
| 564 | H. FLOORING |
| 565 | Ceramic glazed wall tiles 300x300 |
| 566 | Providing and laying rectified glazed Ist quality ceramic glazed wall tiles 300x300 mm or more conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except white,ivory,grey,fume red brown of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 20 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. for dado |
| 567 | Vitrified floor Tile 1200 x 1200 |
| 568 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & mfg, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. for flooring.The tiles must be cut with zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel,piller,wedge,chips of required thickness,levelling system & rubber mallet for placing the tiles gently & easily. Size of Tile 1200x1200 mm for flooring MATT/Antiskid |
| 569 | Ceramic floor tiles 300x 300 |
| 570 | Providing and laying rectified Anti Skid Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. For Flooring |
| 571 | Vitrified floor Tile 600 x 600 |
| 572 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacture in all colours and shede in skirting,riser of steps,laid with cement based high polymer modified quick set tile adhesive ( water based )confirming to IS 15477 in average 6mm thickness including grouting of joints ( payment for grouting of joints to be made separately ). Size of Tile 600x600 mm |
| 573 | Grouting the joints of flooring/wall tiles |
| 574 | Grouting the joints of flooring/wall tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm |
| 575 | POLISHING ON MARBLE/GRANITE |
| 576 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete |
| 577 | I. ROOFING |
| 578 | Structural stell - Build up section |
| 579 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and two or more coats of synthetic enamel paint of approved color, shade and make all complete. The item includes working at an height upto 6 m from the ground/ slab level. |
| 580 | Steel work- tubular |
| 581 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. The item includes working at an height upto 6 m from the existing ground/ slab level. Hot finished welded type tubes |
| 582 | Sandwich panels puff sheet |
| 583 | Supply & erection of insulated sandwich panels puff sheet roofing 50 mm thick,external steel 0.5 mm thick PPGL (TCT) &internal steel 0.4mm internal color RAL 9002 (off white) . |
| 584 | Crimps |
| 585 | Supply & erection ofPrecoated/mill finish aluminium Crimp curve along with all necessary material like screws, washers etc., |
| 586 | Ridges |
| 587 | Precoated/mill finish aluminium Ridges plain (500- 600mm) long with all necessary material like screws, washers etc., |
| 588 | Gutter |
| 589 | Precoated/mill finish aluminium Gutter (600 mm over all girth) long with all necessary material like screws, washers etc., |
| 590 | PVC Rain water Pipe |
| 591 | Rain water unplasticised rigid PVC rain water pipe 110 mm long with all necessary material like screws, washers etc., |
| 592 | False ceiling Gypsum Board |
| 593 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with |
| 594 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 595 | Tiled false ceiling |
| 596 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. GI Metal ceiling Lay in perforated Tegular edge global white color tiles of sie 595x595mm |
| 597 | J. FINISHING |
| 598 | 15 mm Cement Plaster |
| 599 | 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side ofsingle or half brick wall |
| 600 | 18 mm cement plaster |
| 601 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge |
| 602 | Mixing water proofing material |
| 603 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. ( Each means here is per bag of 50kg cement used in the mix) |
| 604 | GI hexagonal chicken wire mesh |
| 605 | Providing and fixing GI hexagonal chicken wire mesh of size 12mm x22g or as required at the junction of dissimilar surfaces of brick masonry wall and R C C column by beams or as required including necessary nails for fixing etc, complete all as per specification and direction of Engineer -in -charge for all floor at all heights. |
| 606 | Primer |
| 607 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surfacehaving VOC content less than 50 grams/litre |
| 608 | CEMENT PUTTY 2MM |
| 609 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 610 | Gypsum lightweight plaster |
| 611 | Providing and applying 12mm thick (average) premixed formulated one coat of gypsum lightweight plaster having additives & light weight aggregates as vermiculite/pertile respectively conforming to IS:2547(Part-I & II) 1976 ,applied on hacked/uneven background such as bare brick/block/RCC work on walls & ceiling at all floors & locations,finished in smooth line & level etc. complete |
| 612 | Acrylic emulsion paint |
| 613 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.TWO COATS |
| 614 | Exterior Paint with Silicone Additives |
| 615 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 616 | Synthetic enamel paint |
| 617 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 618 | FRENCH SPIRIT POLISH |
| 619 | Providing & Applying French spirit polishing :One or more coats on old/new work |
| 620 | K. PLUMBING WORKS |
| 621 | A. SANITARY FIXTURE |
| 622 | Wall mounting Water closet |
| 623 | Providing and supplying white vitreous china wall mount l type water closet (European type) with seat and lid with C.P. brass hinges and rubber buffers, with fittings.: W.C. pan with white solid plastic seat and lid. (Make : jaquar or hindware or Essco or Parryware) - Rimless Blind Installation Wall Hung WC Size: 380x525x375 mm - (Model No: KUS-WHT-35953BIUFSMPM) |
| 624 | Under Counter Basin |
| 625 | Providing and fixing first quality white vitreous china Under Counter Basin with Fixing Accessories Size: 605x430x200 Mm shape: Oval basin for under counter mounting, specially fabricated CI / MS brackets, painted with two or three coats of enamel paint of approved shade over a coat of primer, waste coupling, 32 mm CP brass waste and CP brass cast bottle trap and pipe to wall with CP brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required. (JAQUAR Cat No - CNS-WHT-705 or equivalent) with waste pipe, waste coupling wtc., |
| 626 | URINAL |
| 627 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 628 | URINALS PRESS COCK |
| 629 | Providing & Supplying of Urinal press Cock/valve with Auto Closing System including Wall Flange of approved make and model. |
| 630 | Long Body Bib Cock with Wall Flange |
| 631 | Providing and fixing Long Body Bib Cock with Wall Flange of approved quality conforming to IS:8931 :15 mm nominal bore ( Jaquar model : COP-CHR-107NPM) |
| 632 | C.P. brass angle valve |
| 633 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore (Jaquar model no: OPP-SSF-15053PM) |
| 634 | Toilet Paper Holder |
| 635 | Providing and fixing SS steel toilet paper holder with flap of approved quality: (JAQUAR Model No - ACN-CHR-1151N OR Equivalent as per approved vendor list) |
| 636 | Beveled edge mirror of superior glass |
| 637 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 638 | SS Towel rail |
| 639 | Providing and fixing SS towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (Jaquar model no: CPA-CHR-1111) |
| 640 | CP brass Health faucet |
| 641 | Providing and fixing of CP brass Health faucet with 8mm dia 1mtr. Long PVC tube and wall hook fixed to wall with rawl plug and CP brass screws complete. (Make: Jaquar Cat. No.(ALD-CHR-573) or equivalent make as approved by Engineer-in-Charge) |
| 642 | Long connecting hose |
| 643 | Prividing and Fixing 1.5 feet long connecting hose with nuts at both ends complete.(Make: Jaquar Cat.No.(ALD-CHR-805B) or equivalent make as approved by Engineer-in-Charge) for health faucet |
| 644 | Kitchen sink with drain board |
| 645 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm along with waste pipe, waste coupling wtc., |
| 646 | Sink Cock |
| 647 | Providing and fixing J shaped Sink Cock (Jaquar make:ARI-CHR-39347S) or equivalent make as approved by Engineer-in-Charge) |
| 648 | Bib Cock |
| 649 | Providing and supplying C.P. Brass bib cock with flange and with or without nozzle of approved quality conforming to IS : 8931- 15 mm Nominal bore |
| 650 | B. WATER SUPPLY INTERNAL |
| 651 | CPVC Pipes - Concealed work |
| 652 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVCsolvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 653 | 15 mm nominal dia Pipes |
| 654 | 20 mm nominal dia Pipes |
| 655 | 25 mm nominal dia Pipes |
| 656 | CPVC Pipes - Internal work - Exposed on wall |
| 657 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & |
| 658 | 25 mm nominal dia Pipes |
| 659 | 32 mm nominal dia Pipes |
| 660 | 40 mm nominal dia Pipes |
| 661 | 50 mm nominal dia Pipes |
| 662 | Gun metal gate valve |
| 663 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 664 | 25 mm nominal bore |
| 665 | 32 mm nominal bore. |
| 666 | 40 mm nominal bore |
| 667 | 50 mm nominal bore |
| 668 | Ball valve (brass) |
| 669 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 670 | 20 mm nominal bore |
| 671 | 25 mm nominal bore |
| 672 | Water storage tank |
| 673 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support |
| 674 | C. SOIL, WASTE, VENT & RAIN WATER PIPES |
| 675 | uPVC SWR floor trap |
| 676 | Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper co |
| 677 | uPVC SWR Pipes- Rain water pipes - 160mm Dia |
| 678 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For Rain water pipes). Nothing extra will be paid fo |
| 679 | Soil & waste pipes -110mm Dia |
| 680 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid - 110mm diameter |
| 681 | Soil & waste pipes -75mm Dia |
| 682 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid- 75mm diameter |
| 683 | PVC Pipe - 40mm Dia |
| 684 | Providing, laying and fixing P.V.C. pipe of ---- dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Inside Toilets).Make: Astral, Ashirvad & Prince 40 mm outer dia |
| 685 | Cowl dome UPVC - 110mm Dia |
| 686 | Providing and Fixing in position UPVC ultra violet stabilized 110mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete.Make: Astral, Ashirvad & Prince |
| 687 | Cowl dome UPVC - 75mm Dia |
| 688 | Providing and Fixing in position UPVC ultra violet stabilized 75mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete. Make: Astral, Ashirvad & Prince |
| 689 | 150 mm dia. R.C.C. pipe |
| 690 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 691 | 150 mm dia. R.C.C. pipe |
| 692 | Masonry manhole |
| 693 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 co Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885 |
| 694 | Extra Depth for manhole |
| 695 | Extra for depth for manholes : Size 90x80 cm With Sewer bricks conforming to IS : 4885 |
| 696 | S.W. gully trap |
| 697 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than4.50 kg and frame to be not less tha 150 x 100 mm size P type With sewer bricks conforming to IS : 4885 |
| 698 | Soak Pit |
| 699 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW. drain 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks. |
| 700 | Honey comb brick work |
| 701 | Honey-comb brick work 10 / 11.4 cm thick with common burnt clay bricks at all levels with cement mortar 1:4 (1 cement : 4 coarse sand). |
| 702 | Brick bats for soak pit |
| 703 | Supply & filling of broken brick bats and filling into soak pit of size 120 mm to 40 mm. |
| 704 | Precast RCC perforated drain covers |
| 705 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineering-charge. |
| 706 | 2. ELECTRICAL, CCTV, BIS WORKS |
| 707 | A. SUB-HEAD-I: CIRCUIT POINT WIRING |
| 708 | Primary point |
| 709 | Wiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 710 | Group-C (Primary point ) |
| 711 | Looping Point |
| 712 | Wiring for group controlled (looping) light point /fan point / exhaust fan point/call bell point (without independent switch etc) with 1.5 sqmm FRLS PVC insulated copper conductor cable in surface/recessed PVC conduit and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc.as required. |
| 713 | Group-C (looping point ) |
| 714 | Twin control light point |
| 715 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 716 | GI box along with modular base & cover plate |
| 717 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 718 | 1 or 2 Module |
| 719 | 3 Module |
| 720 | 4 Module |
| 721 | 6 Module |
| 722 | 8 Module |
| 723 | 12 Module |
| 724 | Modular base & cover plate |
| 725 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 726 | 1 or 2 Module |
| 727 | 3 Module |
| 728 | 4 Module |
| 729 | 6 Module |
| 730 | 8 Module |
| 731 | 12 Module |
| 732 | Modular switch/ socket |
| 733 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 734 | 5/6 A switch |
| 735 | 2 way 5/6 A switch |
| 736 | 15/16 A switch |
| 737 | 3 pin 5/6 A socket outlet |
| 738 | 6 pin 15/16 A socket outlet |
| 739 | Modular Blanking Plate |
| 740 | Supplying & Fixing Modular Blanking Plate on the existing modular plate & switch box excluding modular plate as required |
| 741 | Wiring for circuit |
| 742 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 743 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 744 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 745 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 746 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 747 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 748 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 749 | B. SUB-HEAD-II: CABLE TRAYS AND ACCESSORIES : |
| 750 | Galvanised Iron cable tray |
| 751 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ wall with G.I. suspenders including G.I. bolts & nuts, etc. as required to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers, supporting arrangements etc as per drawings/site condition and as required. |
| 752 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 753 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 754 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 755 | Bends |
| 756 | Supplying and installing following size of perforated pre-painted M.S cable trays bends with cover and with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required. |
| 757 | 100 mm width X 50 mm depth X 1.6mm thickness |
| 758 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 759 | Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with cover and with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required. |
| 760 | 100 mm width X 50 mm depth X 1.6mm thickness |
| 761 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 762 | C. SUB-HEAD-III: DISTRIBUTION BOARDS |
| 763 | MCB Board - 415V |
| 764 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 765 | 4 way (4 + 12), Double door |
| 766 | 8 way (4 + 24), Double door |
| 767 | MCB Board - 240V |
| 768 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 769 | 4/6 way (4 + 12), Double door |
| 770 | 8 way (4 + 24), Double door |
| 771 | MCB DB Board - 240V |
| 772 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 773 | 40 amps |
| 774 | 63 amps |
| 775 | C” curve, miniature circuit breaker |
| 776 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 777 | Single pole |
| 778 | Double pole |
| 779 | Triple pole |
| 780 | Triple pole and neutral |
| 781 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 782 | MCB DB |
| 783 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 784 | 63 amps |
| 785 | 100 amps |
| 786 | Single Pole Blanking Plate |
| 787 | Supplying and fixing Single Pole Blanking Plate in the existing MCB DB complete Etc. as required. |
| 788 | D. SUB-HEAD-IV: EARTHING INSTALLATION |
| 789 | Earthing |
| 790 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 791 | G.I. earth plate 600 mm X 600 mm X 6 mm thick |
| 792 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe 2.7 M long etc. with charcoal/ coke and salt as required. |
| 793 | 25 mm X 5 mm G.I. strip |
| 794 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 795 | 6 SWG dia G.I. wire |
| 796 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 797 | E. SUB-HEAD-VI: LIGHTS ITEMS |
| 798 | RECESS MOUNTED LED LIGHT |
| 799 | Supply, fixing, testing and commissioning of 35W/36W 2X2 Feet RECESS MOUNTED LED LIGHT (Correlated Colour Temperature (Nom) 6500 K, THD < 10%, PF >= 0.9 all accessories as required. (Philips Model no: RC380B LED42S-6500 G6 L60W60 PSU OD S1. OR Equivalent as per approved vendor list) |
| 800 | 40 W LED CEILING/ WALL MOUNTED TUBE LIGHT |
| 801 | SITC of 40 W LED CEILING/ WALL MOUNTED TUBE LIGHT with all accessories as required. (4 feet). Colour Temperature - 6500K, 100lm/W . Philips Star Bright Decorative Modern Product SKU : 919615898138 OR Equivalent as per approved vendor list |
| 802 | LED bulk head fitting |
| 803 | SITC LED bulk head fitting 10 watt IP 65 & IK 08 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable. |
| 804 | LED Panel light/ Down light |
| 805 | SITC of 9W/10W LED Panel light/ Down light recessed with all accessories as required. Colour Temperature - 6500K, PF > 0.9. Philips DN295B LED10S-6500 PSE WH S2 OR Equivalent as per approved vendor list |
| 806 | HDPE Pipe 32mm |
| 807 | High density poly ethylene pipes 32mm (HDPE) of pressure rating 6 kgf/cm2 laid in trenches |
| 808 | Exhaust Fan 200 mm |
| 809 | SITC of Exhaust Fan 200 mm Sweep area [ 240V , 1200-1500 RPM , 3 BLADES ] with Lovers |
| 810 | LED square / circular Max. 18 W down lighter/ Panel Light |
| 811 | Supplying and erecting rimless full glow LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 812 | Wall mount fan |
| 813 | Providing & Fixing with connection, high speed wall mount fan of 400 mm of approved make and shade as per the directives of EIC. |
| 814 | F. SUB-HEAD-VIII: CONDUIT,CCTV BIS ETC. |
| 815 | PVC Conduit |
| 816 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 817 | Modular switch/ socket |
| 818 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections, termination, crimping with cable. |
| 819 | RJ 45 female jack / Sockets for Data / Voice outlet |
| 820 | UTP 4 pair CAT 6 LAN |
| 821 | Supplying and drawing of UTP 4 pair CAT 6 LAN, 23 AWG ARMOURED Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 822 | 3. FIRE FIGHTINGS |
| 823 | Photothermal detector |
| 824 | Supplying, installing, testing and commissioning of intelligent analog adressable photothermal detector complete with mounting base complete as required. |
| 825 | Fire alarm armoured cable |
| 826 | Supplying & laying of 2x1.5 spmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 827 | Addressable manual call point |
| 828 | Supplying, installing, testing and commissioning of adressable manual call point complete as required. |
| 829 | Adressable horn cum strobe |
| 830 | Supplying, installing, testing and commissioning of adressable horn cum strobe complete as required. |
| 831 | Smoke detector |
| 832 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connection etc. as required |
| 833 | Fire survival armoured cable |
| 834 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 2 x 1.5 sq.mm |
| 835 | MS flexible pipe |
| 836 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 837 | 4. AC WORKS |
| 838 | (1.5 TON), Inverter Split AC with indoor & outdoor unit |
| 839 | Supply,installation,testing and commissioning of following BEE 5 Star rated (1.5 TON), Inverter Split AC with indoor & outdoor unit and all accessories as per specifications etc. as required including, required outdoor unit frame, core cutting for refringent piping and cable, PVC drain pipe,stands etc. |
| 840 | (2 TON), Inverter Split AC with indoor & outdoor unit |
| 841 | Supply,installation,testing and commissioning of following BEE 5 Star rated (2 TON), Inverter Split AC with indoor & outdoor unit and all accessories as per specifications etc. as required including, required outdoor unit frame, core cutting for refringent piping and cable, PVC drain pipe, stands etc. |
| 842 | Copper piping along with rubber tubular insulation |
| 843 | Supplying, fixing , jointing , testing commissioning of additional required (in addition to supplied copper piping with the AC unit) Interconnecting refrigerant copper pipe work suitable for R-32/R- 410A refrigerant with (9mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor &outdoor units as per specifications for Split AC System including all fixing & routing accessories and are in pair. |
| 844 | SITC for additional |
| 845 | Supply, Installation, Testing & Commissioning of the copper conductor, FRLS, PVC insulated, 1.1kV control cum Transmission wiring in existing surface/recessed steel/pvc conduits between indoor & outdoor units including supply of screened wires, supports, installation, saddles, ties, tags, ferrules, lugs, nuts/bolts/hardware etc. complete in all respects as per specifications and any other item required to make the system complete. 4Cx 6 Sqmm copper |
| 846 | Drain Pipe |
| 847 | DRAIN PIPING Extra Providing and fixing in position the following pipes cut to required lengths and necessary fitting with 9 mm thk.Nitrile Rubber Insulation as per drawing |
| 848 | Electrical Power cable |
| 849 | Extra Power Cable for IDU (2.5sqmm 3 core flexible Cable). Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |