| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm RLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | GROUP C |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 4 sq. mm |
| 6 | Supplying & Laying of one Number multi core flexible PVC outer sheathed copper conductor suitable for rated voltage of 1.1 KV grade ISI marked in following manners. |
| 7 | 3 x 6 sq. mm (in the existing masonry open duct / existing pipe /tray/wall surface as required) |
| 8 | Supplying & Laying of one Number following core PVC/XLPE insulated with PVC outer sheathed armoured Aluminium conductor cable suitable for rated voltage of 1.1 KV grade ISI marked in following manners. |
| 9 | 3 x 4 sq. mm (on wall / existing tray) |
| 10 | Supplying and fixing of following sizes of PVC trunking profile along with accessories fixing on wall surface and making good the same as required. |
| 11 | 50x 50 MM |
| 12 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But Without MCB/RCCB/Isolator) |
| 14 | 16 way , Double door |
| 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | Single pole |
| 17 | Supplying and fixing 63 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | Double pole (63 AMP) |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 20 | Supply of Pendant Circular diffused Industrial Well glass robust and modern lowbay Industrial 35watt LED luminaire with unconventional breakthrough design for illuminating mid and high ceiling of Housing made-up PDC Aluminium with UV Stabilized Injection moulded PC Diffuser to ensure effectively light distribution. Luminaire to have 220-240V AC (Input load type) power supply, Minimum luminaire efficacy >110 lm/W, Minimum lamp life L70B50 ≥50,000hrs, CRI ≥ 80, THD <10%, Power factor >0.95. Integral switched ON-OFF Driver with\inbuilt SPD 4KV and IP 65 protection. control unit, all mounting and installation accessories. |
| 21 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 0/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external Connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 22 | 18- 22 Watt LED Batten light (System lumen efficacy ≥105 <120lm/Watt). LED Powder Coated CRCA Sheet Body (Thickness>0.50 mm) |
| 23 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body With built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 52 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as er LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all espect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 24 | 70 watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). |
| 25 | Supplying and fixing of SMC junction /pole box having size not less than 200mm x140mmx95 mm minimum IP 65 rating, Din mounting with 6 amp MCB support i/c 20mmx3mm Aluminium bus bar support connection, eartthing i/c complete fixing and connection as required. |
| 26 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 27 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 28 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 29 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 30 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 31 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: |
| 32 | 65 mm dia |
| 33 | 150 mm dia |
| 34 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required: |
| 35 | 65 mm dia |
| 36 | 150 mm dia |
| 37 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. |
| 38 | 65 mm dia |
| 39 | 150 mm dia |
| 40 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
| 41 | 150 mm dia |
| 42 | Supply installation and testing and commissioning of Sewage type Submersible pump set having delivery 65 mm dia, discharge minimum 1500 to 220 LPM at minimum head range 12-39 mtr, stainless steel CF8 or CF8M impellers & solid handling capacity minimum 25 mm with hardened stainless steel (SS410) shaft sleeve to protect the shaft from wear at the gland packing area gland packed stuffing box complete TEFC 415 V 50 HZ 2900 rpm IE3 class etc. as required. |
| 43 | 10 HP/7.5 KW |
| 44 | Supply installation and testing and commissioning of Sewage type Submersible pump set having delivery 150 mm dia, discharge minimum 4750 to 280 LPM at minimum head range 8-18 mtr, stainless steel CF8 or CF8M impellers & solid handling capacity minimum 45 mm with hardened stainless steel (SS410) shaft sleeve to protect the shaft from wear at the gland packing area gland packed stuffing box complete TEFC 415 V 50 HZ 1440 rpm IE3 class etc. as required. |
| 45 | 15HP/11 KW |
| 46 | Supplying & fixing of fully automatic star delta control panel suitable for different capacity sewage submersible pump sets complete with all accessories & switchgears on the existing wall / floor etc. complete as required. |
| 47 | 10 HP |
| 48 | 15 HP |
| 49 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 50 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 51 | Supplying & Laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with amendment No. 1 in following manners. |
| 52 | 3 x 25 sq. mm (in the existing masonry open duct/cable tray as required) |
| 53 | 3.5 x 120 sq .mm(in the existing masonry open duct/Cable tray as required as required) |
| 54 | Supplying & Laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with amendment No. 1 in following manners. |
| 55 | 3 x 25 sq. mm (on wall surface as required.) |
| 56 | 3.5 x 120 sq. mm (on wall surface as required.) |
| 57 | Supplying & Laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with amendment No. 1 in following manners. |
| 58 | 3 x 25 sq. mm (in RCC/Hume/Metal/DWC pipe as required.) |
| 59 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 60 | 3 X 25 sq. mm (25mm) |
| 61 | 3½ X 120 sq. mm (45mm) |
| 62 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 63 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 64 | Fabrication, Supplying and installation of outdoor type cubical feeder pillar of M.S. sheet 2mm thick (14 SWG) having Size not less than 1.86 Sqmtr ,Depth 300 mm, duly compartmentalised having 4 strip busbars of 200 amp capacity double door with two nos. godown locking arrangement for protection from rain, dust, duly fixed on M.S. angle iron frame work of size 50 mm X 50 mm X 5 mm (NS) 900 mm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement 2 sand :4 stone aggregate 20 mm) and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminum thimbles, earthing with two nos. earth studs duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as reqd. Supplying & Fixing of following accessories in the existing cubical panel board/feeder pillar including connection testing etc. as reqd.a) Incoming-160Amp 36 KA 4P MCCB with Thermal Magnetic release with Phase barriers and spreader terminals on incoming and outgoing side with rotary handle complete with connections etc. as required-1 Nosb)63 Amp 25 KA 4P MCCB with Thermal Magnetic release with Phase barriers and spreader terminals on incoming and outgoing side with rotary handle complete with connections etc. as required-4 Nos. c)63 Amp FP MCB – 4 set. d)32 Amp DP MCB – 5 set. e) Multifunction meter with suitable CT ratio – 1set. f) RYB LED indicator with control accessories- 1 Set |
| 65 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 66 | Hot finished welded type tubes |
| 67 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 68 | In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 69 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 70 | Providing and fixing of 4.5Kg Carbon Dioxide type (Co2) fire extinguisher confirming to IS 15683 duly enamel painted fully charged, wheel release type valve, delivery hose horn locking arrangement, operating temperature: 30 Deg C to +55 Deg C i/c wall mounting MS. bracket etc. complete as required. |
| 71 | Supplying and laying of rubber Mat of dimension as required as customized as per floor of site having thickness 2.5 mm to withstand 11Kv dielectric strength as per latest IS 15652-2006 etc. as required. |
| 72 | Credit for old dismantled materials |
| 73 | 15HP pump set |
| 74 | Old Starter |
| 75 | Panel with burnt switchgears |
| 76 | Assorted Aluminium cable |
| 77 | MS pipe |
| 78 | Assorted copper wire |
| 79 | light fitting |
| 80 | MS conduit |
| 81 | Assorted Switch socket Please Enable Macros to View BoQ information |