| 1 | [10.93]Providing and Laying of P.O.P on floors with polythene sheet, cleaning, wiping floor and mixing of POP with water on the polythene sheet and removing it after completion and disposing off the same complete in all respects as per direction of Engineer-in-Charge. [Through Rate] |
| 2 | [22.87.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 3 | [23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate] |
| 4 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 5 | [23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm [Through Rate] |
| 6 | [23.24.4.4]MS STAND, BUS BAR CHAMBER AND PANELS 4.4. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 400 amp. [Through Rate] |
| 7 | [24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate] |
| 8 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 9 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 10 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 11 | [24.14.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35 Sq mm 3.5 core (Arm.) [Through Rate] |
| 12 | [24.14.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.) [Through Rate] |
| 13 | [24.2.8.11]LT CABLE 8.11. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 150 sqmm [Through Rate] |
| 14 | [24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm [Through Rate] |
| 15 | [24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate] |
| 16 | [24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm [Through Rate] |
| 17 | [25.7.1]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet [Through Rate] |
| 18 | [25.7.2]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheet [Through Rate] |
| 19 | [30.94]Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, up to 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal and vertical tubes joint with cup and lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. [Through Rate] |
| 20 | SITC of O-General/Mitshubishi/Daikin/Carrier/ BLUESTAR Make Air Cooled Ductable Air-conditioning units comprising of ImportedScroll Compressor, DX Evaporator coil,thermostatic expansion device, air- cooled condensers with specially coated fins, centrifugal blower, TEFC Motor, Micro- processor based control panel etc. All items shall be encased in sheet metal cabinet with first charge of refrigerant gas,Vibration Isolation pads, liftingshifting and positioning of indoor and outdoor units including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. following capacities:Capacity 22TR |
| 21 | Supply and ref gas R-410 A including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. |
| 22 | SITC of Hard copper refrigerant piping Both suction and discharge insulated with nitrile tube and supported including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. Make :- MAXFLOW/MANDEV/VENUS |
| 23 | SITC of 6 core x 2.5 mm Interconnecting electrical cabling for Ductable splits units between indoor and outdoorunits including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. |
| 24 | SITC OF MS wall mounted type stand for Ductable split outdoor units including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. |
| 25 | SITC OF Duct Insulation with 9 mm thick nitrile rubber insulation with adhesive including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. |
| 26 | SITC OF Duct Accoustic lining with 9 mm thick nitrile rubber insulation with adhesive including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. |
| 27 | SITC OF Aluminium Powder coated supply/ return air Diffuse including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. |
| 28 | SITC OF MS Volume Control Damper for supply air duct collars including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. |
| 29 | SITC OF Canvass connection fire retardant including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. Please Enable Macros to View BoQ information |