| 1 | Dismantling of existing structures like culverts, bridges, retaining walls and other sturcture comprising of masonry, cement concrete wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable materials and stacking the serviceable materials with all lifts and lead of 1000m as per Technical Specification Clause 202 |
| 2 | Construction of granular sub-base by providing close grade granular sub-base grading-III material as per table-100-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per clause 401 of MOSRT&H Specifications for Road & Bridges work (4th Revision)(A/R-2006 page-160 item No-39). |
| 3 | Providin, laying, spreading & compacting graded stone aggregate to to Wet Mix Macadam specification including pre mixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in sub base/base course on well prepared surface & compacting with vibratory roller to acieve the desired density as per clause 406 of MoSRT & H specifications for road & bridge works.(4th Revision) |
| 4 | Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub-base, with 43 grade cement or any other type as per Clause 1501.2.2, M30 (grade) coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars near approaches to bridges and culverts (expansion joints), admixtures as approved, curing of concrete slabs for 14 days, curing compound and water finishing to lines and grade as per drawing and Technical Specification Clause 1501. |
| 5 | Earth work in excavation of fondation in hard soil within the initial lead & lift including dressing & levelling the bed & depositiong the excavated earth away from the site etc. all complete as per the direction of Engineer in Charge. |
| 6 | Filling sand-Supplying & filling good clean river sand of approved quality including watering to complete saturation & ramming complete with all leads & lifts including cost, conveyance, royalty & taxes of all materials & cost of all labour & T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
| 7 | Providing and laying reinforced cement concrete pipe NP3 for culverts including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106 of MoRD but excluding the charges of GST & as per direction of the Engineer-in-Charge.(i) 1000 mm dia Single row |
| 8 | Supplying, fitting and placing HYSD bar reinforcement complete as per drawings and technical specification Clauses 1000 and 1200 of MoRD and as per direction of the Engineer-in-Charge. |
| 9 | PCC M-15 grade in foundation bed using 40mm to 10 mm size crushed stone aggregates mixed by concrete mixer laying in layers and compacting by vibrator & all leads and lifts as per approved drawing & technical specification and as per section 1700& 2100 of MORTH specification for road and bridge works (latest revision) but excluding the charges of GST including cost conveyance etc required as directed by Engineer-in-charge. (A) Foundation |
| 10 | (B) Sub-Structure |
| 11 | R.C.C work of M-25 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including cost, conveyance, royalty & taxes of all materials & cost of all labour & T&P required for the work etc. complete as per specification & direction of Engineer in charge. Super-Structure |
| 12 | Providing Weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 of MORD specification for Rural roads but excluding the charges of GST and as per direction of Engineer-in- charge. |
| 13 | Reinforced cement concrete M15 grade Kilometer stone/ local stone of standard design as per IRC:8 fixing in position including painting & printing etc. as per the drawing &technical specification clause 1703 of MoRD but excluding the charges of GST and as per direction of Engineer-in-Charge. (A) Fixing of Km. Stone |
| 14 | 200 mm Stone (Precast) |
| 15 | Guide Post (M-20) |
| 16 | Providing and erecting Informatory retro-reflectorised sign as per IRC-67-2012 made of class-B retro-reflective sheeting of high intensity prismatic grade sheeting as per ASTMD4956-09type-III and IV strictly conforming to clause 6.7of IRC67-2012 and vide clause 801.3, fixed over aluminium sheeting, 2.00mm thick as per clause 6.5.2 of IRC:67-2012 or A.C.P (Aluminium Composite Panel) used for sign boards with a thermo plastic core of blow density polythylene (LDPE) between two thick sheets of aliminium with over all thickness of 4mm and aliminium thichness of 0.5mm on both sides supported on mildsteel square post 80mmx80mmx3mm, 2nos and 5nos horizontal and 3no vertical extra supporting member of M.S pipe of size 50mmx50mmx3mm firmly fixed to the ground by means properly designed foundation withM-15 grade cement concrete 90cmx90cmx15cm, 150cm below ground level of as per approved drawing including cost, conveyance, royality, taxes of all materials, labour, T&P, excavation, curingetc. complete,under supervision of Engineer-In-Charge.Size-12'X8'(3657mm x 2438mm Rectangle) Information signs |
| 17 | Providing and fixing of typical Citizen sign board with logo as per MORD specifications and drawing. Two MS plates of 2mm thick, top & middle plate duly welded with MS flat iron 25mmx5mm size on back on edges. The flat iron frame of both plate will be welded to 2nos 75mmx75mm of 12SWG sheet tubes posts duly embeded in C.C. M-15 grade blocks of 600mmx600mmx750mm, 750mm below ground level. The top most dimond plate will be welded to middle plate by 47mmx47mm of 12SWG steel tube. All M.S. will be stove enameled on both sides. Lettering & printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quailty in required shade & colour. All sections of framed posts & steel tubes will be painted with primer & two coats of paint as per drawing clause 1701 and Annexure 1700.1 |
| 18 | Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 etc complete including cost conveyance etc required as per specification but excluding the charges of GST & direction of Engineer-in-Charge. (A) 600mm equilateral triangle |
| 19 | (B) 600mm Circular |
| 20 | Maintenance WorkRestoration of rain cuts with soil, moorum gravel or a mixture of these, clearing the loose soil, benching for 300mm width laying fresh material in layers not exceeding 250 mm and compaction with plate compactor or power rammer to restore the original alignment ,level and slopes as per technical specification Clause 1902. 1 st Year |
| 21 | 2nd Year |
| 22 | 3rd Year |
| 23 | 4th Year |
| 24 | 5th Year |
| 25 | Making up loose of material/irregularities on shoulders to the design level by adding fresh approved selected soil and compacting it with appropriate equipment at OMC upto a lead of 1000 m as per technical specification Clause 1903. 1 st Year |
| 26 | 2nd Year |
| 27 | 3rd Year |
| 28 | 4th Year |
| 29 | 5th Year |
| 30 | Stripping excess soil from the shoulder surface to achieve the approved level and compacting with plate compactor at OMC as per drawings and Technical Specification Clause 1903 1 st Year |
| 31 | 2nd Year |
| 32 | 3rd Year |
| 33 | 4th Year |
| 34 | 5th Year |
| 35 | Repair to pot holes and removal of loose material, trimming of sides, cleaning of surface by providing tack coat, 20 mm thick pre-mix carpet and seal coat type C as per MORD technical specification Clause 503,508,510,1904 as per direction of the Engineer in charge. 1 st Year |
| 36 | 2nd Year |
| 37 | 3rd Year |
| 38 | 4th Year |
| 39 | 5th Year |
| 40 | Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908. 1 st Year |
| 41 | 2nd Year |
| 42 | 3rd Year |
| 43 | 4th Year |
| 44 | 5th Year |
| 45 | Maintenance of 200 metre km stone by way of refiting of tilted stones repairing with cement mortar, cleaning, repairing and lettering on 200 metre km stone and 5th km stone as per drawing and technical specification Clause 1912. 1 st Year |
| 46 | 2nd Year |
| 47 | 3rd Year |
| 48 | 4th Year |
| 49 | 5th Year |
| 50 | Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914. 1 st Year |
| 51 | 2nd Year |
| 52 | 3rd Year |
| 53 | 4th Year |
| 54 | 5th Year |
| 55 | Cutting of shrubs from the road way or with in R.O.W and disposal of shrubs to suitable locations as per technical specifications Clause 1914. 1 st Year |
| 56 | 2nd Year |
| 57 | 3rd Year |
| 58 | 4th Year |
| 59 | 5th Year |
| 60 | Trimming of grass and weeds from the shoulders/berms and disposing off the same to suitable locations as per technical specifications Clause 1914. 1 st Year |
| 61 | 2nd Year |
| 62 | 3rd Year |
| 63 | 4th Year |
| 64 | 5th Year Please Enable Macros to View BoQ information |