| 1 | Providing Campus Lighting:- |
| 2 | Supply and Erection of 70 Watt LED Street Light fitting (including LED driver) suitable for energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07, THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse auredited LAB. |
| 3 | Supply and Erection of Decorative Pole 6 Meter long with Decorative bracket. Architectural Lighting Pole is design to create a distinctive atmosphere in town & cities by using the most advanced technology to develop innovative lighting solutions. Poles can stylishly convey the identity of any landscape. Our poles can be designed to suit single or multi arms brackets in order to install one or more light sources. Product Description:- • Pole made of Galvanized and steel types. • Pole design parameters vary depending on the type of bracket and loading factor. • Conical pole are welded using saw welding technique by certified welders by using automatic machine with precision welding. • Other Welding using special v groove technique by certified welders using high end MIG welding processes. • Built-in control box with service door and safety rope. • Service door is contoured to the shape of the pole with rubber gasket. • The control gear tray is prewired with MCB, terminal connectors for loop-in / loop-out arrangement. • The foundation bolt holes in the base plate are designed to be elongated for fine adjustments / alignment of the pole during installation. • Base plate made of steel grade E250 & foundation bolt of grade 4.6 including RCC Foundation of size 2x2x4 mm depth. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 4 | Supply and Erection of 50/60w LED Decorative drop down light made of cast Aluminium span Aliminium clear Acrylic(A9) housing fitted with clear/Polycarbonate diffuser Aluminium heat sink. Input power 60w with THD less tha 10%with driver efficiency greater than 55%, operating voltage range 100-270 V with output open circuit protection, short circuit protection and over voltage protection with internal surge protection 5KV and output surge protection 10 kv. Luminous flux 3000/4000/5700 k. IP Grade 66, Minimum CRI 70. LED Life 50000 Hrs min. Complete in all respects as approved and desired by Engineer In charge at site. |
| 5 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 6 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 7 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 8 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 9 | G.I. EARTHING: Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 10 | GI Earth rod 20 mm dia. 3 mtr. Long |
| 11 | Upgrading of existing Sub Station System:-INDOOR LT PANELS: LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). |
| 12 | SUB LT PANEL (NORMAL): LT Panel enclosure having space for 1No. Incomer MCCB 630Amp. and 6Nos. outgoing MCCB's 40amp. to 250amp. (Option: MCCB 200-250amp.= 2Nos. and MCCB's 40-100amp.= 4Nos.) according to the requirement at site (Approx. size 1475 x 1800 x 400mm) |
| 13 | MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc |
| 14 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 15 | MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 16 | MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 17 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 18 | Overall size 400sq.mm (3½ Core) Un-armoured (Loose) |
| 19 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 20 | Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.) |
| 21 | ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure):Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- |
| 22 | On Load Change Over Switch Four Pole 400amp., 415volts |
| 23 | INDOOR LT CABLES, CABLE TRAY & DWC PIPE:CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 24 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 25 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 26 | Brass Gland for Aluminium cable 3/3½/4 Core size 400sq.mm |
| 27 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 28 | Aluminium thimble cable Core size 240sq.mm |
| 29 | Aluminium thimble cable Core size 400sq.mm |
| 30 | COPPER EARTHING COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 31 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 32 | COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 33 | Additional Length 20mm x 3mm thick Copper Tape |
| 34 | 8 SWG COPPER EARTHING :Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 35 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 36 | Charges of ACB Servicing including Maintenance, Closing tripping coil, contact relays etc. (2) VCB Servicing including Maintenance, Closing tripping coil, Vacumm interruptor checking, IR test, COOC operation test, High pot test etc. (3) Dry type Transformer Servicing including visual inspection of trasformer core, tightining of HVLV terminal, IR test, PI test, turn ratio test, temprature sensor test etc. (4) Bus Bar contact resistance test, Measurement and IR test etc. complete in all respect. |
| 37 | Providing Advance Lightning Protection System:- |
| 38 | Supply, installation, testing & commissioning of fully autonomous Early Streamer Emission Lightning Air Terminal (ESEAT) comprising of floating panels/body isolated from an earthed central finial/tip (elevated sharp tip) on top of the highest point to protect from direct lightning strikes with the following technical parameters. As per NF C 17-102 : 2011, (Annexe C), Clause C.3.4 ESE terminal is tested & certified for the below parameters. • ESE air terminal should be tested for an Impulse current (10/350 micro sec)=103 KA • Charge (Q) = 54.9 A.s • Specific Energy (W/R) = 2500 KJ/Ω and as per Clause C.3 all the tests should be carried out on a sample (preferably all tests in one lab) according to the flow chart in figure C.1 (Sequence of testing) pg 69 i. General tests, ii. Mechanical tests, iii. Environmental tests, iv. Electrical tests, v. Early Streamer Test (Δt in 10μs to 60 μs and standard deviation) • For the local certification, the ESE air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) or more. LPI is Tested & certified by CPRI (Central Power Research Institute), Govt of India for the Impulse current of 70 KA with 5 positive & 5 negative impulse • The International testing laboratory should be duly accredited by ILAC / IEC / ENAC / EZU / UL to ensure the genuine testing and the quality of the product. The serial number displayed on the ese lightning arrester is duly supported with the \\"certificate of country of origin\\" issued and duly sealed by the Australian Government \\"Chamber of Commerce & Industry\\". Complete in all respect and as per design and size approved by engineer incharge at site. |
| 39 | GALVANIZED IRON PIPES AND G.I. EARTHING: Supply & erection of G.I. pipe (A-Class) as per IS:1239 (Part-I) 2004 including sockets, bends, inspection boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 40 | Galvanized Iron Pipe 50mm dia. (A-class) Flushed |
| 41 | COPPER EARTHING (Upto 14 metre in Length):-iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 42 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 43 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 44 | Overall size 70sq.mm (Un-sheathed) |
| 45 | Providing Lifts 1 Nos. 8 Passengers (2 STOPS): |
| 46 | Supply, installation, testing and commissioning of 1 No. lift of 8 passengers machine room less.Type and Capacity : Approximately 544 Kg, 8 Passengers Speed:1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately 8 meter________ Serving: _2 Floors _2 Stops _2 Openings _2 Levels (All on the same side) Hoist way Required: 1800mm (Wide) x 1600mm Clear dimensions Headroom Height (HR): 4170 mm beyond finished floor level of last landing Pit Depth: 1400mm below the finish floor level of first landing Car dimension : 1100x 1300x 2200 mm Car door size : 800x 2000 mm Car Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof/ Honeycomb/ Linen).Car Entrance: Center Opening Automatic Doors of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 800mm (wide) x 2000mm (high) Fire Retardent Ten min. of 120 Minutes Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features. |
| 47 | Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Rescue Device to bring the Elevator to the nearest landing in case of power failure. |
| 48 | Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Rescue Device to bring the Elevator to the nearest landing in case of power failure. |
| 49 | 28. The use of visually and acoustically reflective Wall suarce should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairments.29. The floor of the lift car should be slip resistant and have similar frictional qualities to the floor of lift landing to decrease the risk of Stumbling.30. The provision of a mirror on the wall of the lift car opposite the lift door does not extend below 900m from the lift floor to avoid confusing people with impaired sight.31. The Emergency communication system should be coupled with an induction loop system installed all sound the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids. |
| 50 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 51 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 52 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 53 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 54 | COPPER EARTHING (Upto 14 metre in Length):- |
| 55 | Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length) |
| 56 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 57 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 58 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 59 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 60 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: |
| 61 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 62 | MCCB's (MOULDED CASE CIRCUIT BREAKER): |
| 63 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 64 | MS SHEET ENCLOSURE FOR MCCB's: |
| 65 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 66 | Add 1% Cultural Cess. Please Enable Macros to View BoQ information |