| 1 | Schedule 'A' |
| 2 | M & L for Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out in soft and loose soil complete all as specified and directed. |
| 4 | M&L for PCC 1:3:6 Type C1 (Nominal mix) (using 20mm graded stone aggregate), as in post holes, foundation, filling and mass concrete complete all as specified and as directed. (Note:- using dimapur sand) |
| 5 | M&L for PCC 1:3:6 Type C2 (Nominal mix) (using 40mm graded stone aggregate), as in post holes, foundation, filling and mass concrete complete all as specified and as directed. (Note:- using dimapur sand) |
| 6 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 7 | M & L for PCC 1:4:8 Type D2 (Nominal mix) (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed. (Note:- using dimapur sand) |
| 8 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. |
| 9 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:4) complete all as specified and directed. |
| 10 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 11 | Ditto all as per Sl item No. 9.00 here-in-above but except brick (NOTE: Seviceable brick obtained from demolition under Sl item No 7.00 here-in-above shall be reused under the item) |
| 12 | M&L hardcore of gauge n exc 63mm, broken stone or boulders deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface completed all as specified and directed. |
| 13 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 5cm but n exc 10cm wide completed all as specified and directed. |
| 14 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed. (Using dimapur sand) |
| 15 | M&L for 75 mm thick cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in sub base,hardstanding,path complete all as specified and as directed by the Engineer-in-Charge. |
| 16 | M&L for 100 mm thick cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in sub base of floor finishes, finished even and rough to receive floor tiles with cobing completed all as specified and directed. |
| 17 | M&L for PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 18 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 19 | M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick set jointed with grey cement and pigments and pointed in neat cement slurry in floors including 15mm thick sreed bed in CM 1:4 complete all as specified and directed. |
| 20 | M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick set jointed with grey cement and pigments and pointed in neat cement slurry in floors including 20mm thick sreed bed in CM 1:6 complete all as specified and directed. |
| 21 | M&L for plain cement concrete type B0, 1:2:4, (using 12.5 mm graded stone aggregate), as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 22 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in lintel upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, facing courses, parapets and railing upto 60 cm in height , coping, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and as directed. |
| 23 | M & L for PCC 1:3:6 type C1 (20 mm graded aggregate) as in coping including necessary formwork etc complete all as specified and directed. |
| 24 | M& L PCC (1:2:4) type B1 using 20mm graded stone aggregate as in benching of drain complete all as specified and directed. |
| 25 | M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed.Note : (i) WPC will be measured and paid separately (ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account. |
| 26 | Supply only intergral water proofing compound complete all as specified and directed. |
| 27 | M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 28 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soft/loose soil complete all as specified and as directed. |
| 29 | Removing excavated material/soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 30 | Removing excavated material exc. 250m but n. exc. 500m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified. |
| 31 | Removing excavated material exc. 500m but n. exc. 1.5Km and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified. |
| 32 | S&F PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joints laid in trenches or in floors with steel clamps complete all as specified and directed. |
| 33 | M&L for MS works as in Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 34 | M&L for Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 35 | S&F MS angle iron as in posts and struts as in fencing including cutting tops to shape as directed, drilled holes notching for wire etc incl all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165.complete all as specified and directed. |
| 36 | S&F steel flat iron including necessary drilling hole bolting or reveting etc and similar work complete conforming to Fe -290 Gde E - 165 complete all speciified and directed complete all speciified and directed. |
| 37 | M&L for round steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all speciified and directed. |
| 38 | S&F 12mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and secured the other or screwed the both ends each screwed ends to be fitted with washer and one hexagonal or square nuts exc 5cm and n.exc 10cm long complete all as directed. |
| 39 | Supply only Chain link MS galvanisd fencing, any size or type weighting not less than 2.80 Kg/Sqm complete all as specified and directed. |
| 40 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 41 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured).complete all as specified and directed. |
| 42 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 43 | Ditto as per items No 63.00 here-in-above but 5mm and over upto & incl 10mm dia in stirrups, spaces and binders complete all as specified and directed. |
| 44 | M&L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 45 | M&L for preparation of new steel surfaces of any description, not otherwise described, not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 46 | M&L for preparation of old painted surfaces of steel of any description over 10cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 47 | S&F Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified. |
| 48 | S&F 1mm thick Mild steel, plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams including bending or turning up, mitred angles, etc. as required complete all speciified and directed. |
| 49 | Demolition of stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar complete all as specified and directed. |
| 50 | Removing building materials etc. to a distance of 1000m, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed. |
| 51 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing , including screed bed 20mm thick in CM 1:3 complete all as specified and directed. |
| 52 | M&L for machine cut kota stone slab 20-25mm thick in riser of steps,skirting,dado and pillar over & including 10 mm cement mortar backing in cm (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 53 | Dismantling floor, hearth , chequred tiles, interlocking tiles tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 54 | S&F Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile including 10mm thick cement mortar backing in CM (1:4) as backing coat to receive tiles complete all as specified and directed. |
| 55 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including screed bed 20mm thick in CM 1:3 complete all as specified and directed. |
| 56 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work.complete all as specified and directed. |
| 57 | M&L for Reinforced cement concrete ( nominal mix) type B0 (1 :2:4) (using 12.5 mm graded stone agg.) as in Slabs supported on walls,beams and columns in floors, roofs/chajja, landings, balconies, canopies, deck slabs and in shelves and the like roof complete all as specified and directed. |
| 58 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. flat rough finished surface of concrete complete all as specified and directed. |
| 59 | S&F 15mm bore bib taps, cast copper alloy, chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed. |
| 60 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including setting and jointing with solvent cement complete all as specified and directed. |
| 61 | S&F in repair Gun-metal (ISI marked), globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20mm bore and fixed complete all as specified and directed. |
| 62 | Taking up or down 15mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed. |
| 63 | S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 64 | Refixing of old 15mm GI tubing and connections on new or old position (walls, ceilling, floor etc) complete all as specified. |
| 65 | Taking up or down 20mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed. |
| 66 | S&F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 67 | Refixing of old 20mm GI tubing and connections on new or old position (walls, ceilling, floor etc) complete all as specified. |
| 68 | S&F PVC SWR pipes 75 mm bore single socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and directed. |
| 69 | S & F 110 mm bore PVC (SWR) branch bends of any radius complete all as specified and directed. |
| 70 | Dismantling water tanks capacity exc. 500 litres and n.exc. 1000 liters and removing to store complete all as specified and directed. |
| 71 | S&F rotational moulded polyethylene water storage tank, ISI marked, 1000 litres capacity of multilayered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including all necessary inlet/outlet connections like ball brass valves of 20mm dia, high pressure with polythene float and fly nut complete, screwed for iron pipe of brass ferrule and fixed in 20mm bore GI tube complete all as specified in SSR Part-I and as directed. Please Enable Macros to View BoQ information |