|
| 1 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for foundation, shafts, cesspits, manholes, pier holes, etc and getting out in in any type of soil complete all as specified and directed. |
| 2 | Returning filling in any type of soil including spreading levelling watering and well ramming in layers n. exc 25 cm complete all as specified and directed. |
| 3 | Removing excavated material exc. 500 m but n exc. 1.5 km and depositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed. |
| 4 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) 200 mm thick as in foundation , sub base concrete etc complete all as specified and directed. |
| 5 | M&L for Moorum filling in sub base brought from outside MD land with any lead, including spreading, levelling, watering & well ramming, in layers not exc 15 cm each complete all as specified and directed. |
| 6 | M&L for hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 7 | M&L for 150 mm thick cement concrete type B-1,1:2:4 (20mm graded aggregate) using mechanical mixer and surface vibrator complete all as specified and directed. |
| 8 | M&L for 25 mm thick Wearproof topping as per manufacturers instructions as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complete all as specified and directed. |
| 9 | M&L Mild steel TMT bars 6 to 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 10 | M&L for fly ash brick work with modular bricks straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 11 | M&L 15mm thick rendering in CM 1:4 on brick/concrete/stone masonry surfaces including finishing the surfaces even and smooth (without using extra cement) complete all as specified and directed. |
| 12 | M&L for cement concrete Type B-1, 1:2:4 using 20 mm graded stone aggregate as in bed blocks, copings, kneelers, apex stones, bed plates, lintels and the like etc complete all as specified and as directed. |
| 13 | M&L for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 14 | Excavating in post holes in any type of soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, incl removing of surplus soil complete all as specified and directed. |
| 15 | M&L Plain cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundations / mass concrete complete all as specified and directed. |
| 16 | S&F rolled mild steel work as in rafter, purlins, trusses, posts, poles etc. and like (beam, tee, angle, channel or flat sections (Fe 410-W(Gde E-250 quality) complete all as specified and directed. |
| 17 | M&L for preparation of new or previously untreated surfaces of steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer, complete all as specified and directed. |
| 18 | S&F pre- painted galvalume aluminum zinc coating GI Based corrugated steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas, fixed with self tapping screws complete all as specified & directed |
| 19 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 20 | Supply and erect steel tubular pole 11 mtrs type 410 SP-55 long including makin alternate yellow and black strips 30 cms height (04 Nos strips) numbering the pole by 2\\" height letters with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 21 | Supply and fix in repairs metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, station class, medium duty, nominal discharge current 10 KA, switching impulse discharge current 1 KA, repetitive charge transfer rating (Qrs) more than 1.6 C, thermal energy rating (Wth) more than 7 KJ/KV, nominal system voltage 33 KV, highest system voltage 36 KV, rated voltage of arrester 27 KV, continuous operating voltage 21.6 KV, temporary overvoltage (30.45 KV for 1 s, 28.50 KV for 10 s, 26.35 KV for 100 s), rated short circuit current 20 KA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 170 KV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 70 KV, switching impulse residual voltage (30/60 µs) at switching impulse discharge current maximum 57 KV, high current impulse withstand capability (4/10 µs) 100 KA, minimum creepage distance 900 mm complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 22 | Supply and fix in repairs metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, station class, medium duty, nominal discharge current 10 KA, switching impulse discharge current 1 KA, repetitive charge transfer rating (Qrs) more than 1.6 C, thermal energy rating (Wth) more than 7 KJ/KV, nominal system voltage 33 KV, highest system voltage 36 KV, rated voltage of arrester 27 KV, continuous operating voltage 21.6 KV, temporary overvoltage (30.45 KV for 1 s, 28.50 KV for 10 s, 26.35 KV for 100 s), rated short circuit current 20 KA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 170 KV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 70 KV, switching impulse residual voltage (30/60 µs) at switching impulse discharge current maximum 57 KV, high current impulse withstand capability (4/10 µs) 100 KA, minimum creepage distance 900 mm complete all as specified and as directed. Please Enable Macros to View BoQ information |