| Sl. No. | Item Description |
| 1 | Supply and fix PCB kit for BLDC ceiling fan of any make and description including dismantling of old PCB complete all as specified and directed. |
| 2 | Disconnecting and taking down of burnt winding of exhaust fans including necessary dismantling, cutting and removing of unsv windings, cleaning, segrigation of serviceable and unsv parts including re-windings of stator winding with super enameled copper wire of existing gauge and weight of approved make and brand and taping, quick heat varnishing, baking, drying in heat chamber to obtain proper insulating resistance and reassembling the fans including replacement of unsv parts and re-installation to the existing position and necessary transportation and testing complete for exhaust Fan of 450 mm sweep of any make complete all as specified and as directed. |
| 3 | All as per item No 2.00 above but for Exhaust Fan of 300 mm sweep. |
| 4 | All as per item No 2.00 above but for cabin/ padestal fan of 380 to 400 mm sweep of any make.Note For item No 2 to 4 : Rates are deemed to be inclusive for collection of fan from AGE E/M yard under contractor own arrangement, removing defective parts, burnt winding carefully, cleaning & re-assembling the fan after repair i.e. oiling, greasing, washer, lock bolts, connector, cross pin etc, depositing back to AGE E/M yard and testing complete to the satisfaction of Engineer-in-charge. (spare parts will be measured and paid seperately under relevent items) |
| 5 | Supply only Ball bearing of size 6201 |
| 6 | Supply only Ball bearing of size 6202 |
| 7 | Supply only Ball bearing of size 6203 |
| 8 | Supply only Ball bearing of size 6204 |
| 9 | Supply only fan capacitor 3.15 mfd . |
| 10 | Supply only fan capacitor 2.5 mfd |
| 11 | Supply only fan capacitor 4 mfd |
| 12 | Supply only Twisted twin core flexible cable of size 24/0.0076 . |
| 13 | Supply only Gun metal bush for ceiling fan of any size. |
| 14 | Supply only Gun metal bush for exhaust fan of any size . |
| 15 | M&L for spray painting of ceiling fan 1200/ 1400 mm sweep with synthetic enamel paint including filing cavities with filler after cleaning of body, blades, down rods etc by scraping with emery paper including rewriting MES No of fan of letter size 2 cm height, using black paint all as directed. |
| 16 | M&L for spray painting of exhaust fan 300 to 400 mm sweep with synthetic enamel paint including filing cavities with filler after cleaning of body, blades, down rods etc by scraping with emery paper including rewriting MES No of fan of letter size 2 cm height, using black paint all as directed. |
| 17 | Fixing only exhaust fan of any type/sweep after servicing and connecting up including provision of cable of size 23/.0076 from ceiling rose/connector to fan complete all as specified and directed. |
| 18 | Making hole for exhaust fan of suitable size (square/ round) and grouting nuts and bolts of suitable size in and including complete platering and make the disturbed surface as per existing wall complete all as specified and directed. |
| 19 | Supply and fix in repairs down rod for ceiling fan made out of 15 mm dia MS pipe complete with holes, slotted or threaded upto 0.6m long all as specified and directed. |
| 20 | All as per item No 19.00 here-in-before but 0.75 to 1.50m long. |
| 21 | All as per item No 19.00 here-in-before but 1.50 to 3.0m long. |
| 22 | All as per item No 19.00 here-in-before but 3.0 to 6.0m long. |
| 23 | Supply and fix in repairs ceiling fan clamps of heavy duty as per sample including nut, bolt, spring washers, cross pin and rubber reel etc all as specified and directed. |
| 24 | Supply and Fix in repairs ceiling fan canopy(set of two) with nut and bolt of suitable size complete all as directed and specified. |
| 25 | M&L in replacement of rubber reel for ceiling fan suitable for 1200/1400 mm sweep ceiling fan complete all as directed and specified. |
| 26 | M&L in replacement of wall fan blades as per existing pattern and size complete all as directed at site complete all as directed and specified. |
| 27 | M&L in replacement of Ceiling fan blades as per existing pattern and size (set of three) complete all as directed and specified. |
| 28 | M&L in replacement of Exhaust fan blades with louver metallic body as per existing pattern and size (set of three) at site complete all as directed and specified. |
| 29 | Taking down the water heater (Geyser)storage type of any make of 25/35/50 litres capacity from any position, after disconnection of all electrical, water supply inlet and outlet connection and transportation to workshop for repair, further dismantling, segregation of serviceable and unserviceable parts, replacement unserviable parts and re-assembly the water heater and installation the same to their original position or as directed after all testing the of water heater complete all as specifed and as directed by the Engr-in-charge.Note : (a) Cost of transportation shall be deemed to be included in the item rate.(b) Replacement of defective parts shall be measured & paid separately under this BoQ items.(c) Descaling/ Welding/breezing/Painting of water heater if required shall be measured & paid separately under this BoQ items. |
| 30 | M& L for welding/breezing of water heater tank of any size, model at appropriate/bursting area of copper/mild steel inner tank and make 100% leak proof complete all as specifed and as directed. |
| 31 | M&L for descaling of water heater storage tank of any type, size and make by appling descaling solution. |
| 32 | M & L for appling one coat of synthetic enemal paint first grade of approve make and colour by spray machine after preparation steel surfaces including writing MES No of 40mm size of letter for 50/35/25 Ltrs capacity of water heater complete all as specifed and as directed. |
| 33 | Supply and fix inner tank made of stainless steel for water heater of 50 ltrs capacity of exiting type, model complete all as specifed and as directed. |
| 34 | Supply and fix inner tank made of stainless steel for water heater of 25/35 ltrs capacity of exiting type, model complete all as specifed and as directed. |
| 35 | Supply and fixing apparatus plate suitable for water heater 25 / 35 / 50 ltrs capacity of approved make and as per exiting type and size incl rubber gasket, clips, nuts, bolts, and washers etc complete all as specifed and as directed. |
| 36 | Supply and fixing in repair thermostat switch (ISI mark) suitable for 25 / 35 / 50 ltrs capacity water heater (geysers) complete all as specified and directed. |
| 37 | Supply and fixing in repair heating element (rounded / threaded rounded / trangular type base) of capacity 1500/2000 watt suitable for horizontal/ vertical type of geysers 25 / 35 / 50 ltr capacity (ISI mark). |
| 38 | Supply and fixing in repair neon indicating lamp, rectangular /round type as per existing model complete all as specified and directed. |
| 39 | Supply and fixing in repair pressure release valve 15 mm bore (ISI marked) for geyser 25 / 35 / 50 ltrs capacity. |
| 40 | Supply and fixing in repair safety valve for water heater of capacity 25/50 ltrs complete all as specified and directed. |
| 41 | Supply and fixing in repair heating element high quality product compaitable with all brand modelsshock proof of capacity 1500/2000 watt suitable for vertical type of geysers 25 ltr capacity (ISI mark) complete all as specified and directed. |
| 42 | Supply and fixing in repair apparatus plate rubber gasket suitable for six/seven/eight/nine hole assembly of suitable size of water heater of capacity 25/35/50 litres capacity. |
| 43 | Supply and fixing in repair split bottom cover (two pieces) suitable for water heater 25/35/50 litres capacity duly painted, all as directed by Engr-in-Charge. |
| 44 | Supply and fixing 100 mm long and 12 mm dia anchor fastner nut and bolt with suitable washers complete all as specifed and as directed. |
| 45 | M&L for insulating material (glass wool) suitable water heater insulation complete all as specifed and as directed. |
| 46 | Supply and fixing in repair hot and cold type PVC connection (ISI Mark) having 10 mm dia, 45 cm long with 02 Nos of Unions/ cup shaped pvc cover with washers complete all as specifed and as directed. |
| 47 | Supply and fixing in repair 2.5 Sqmm 3 Core (Nominal Area) PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 complete all as specified and as directed. |
| 48 | Taking down window/Split type air conditioner for complete serviceing & cleaning with water and suitable cleaning agent properly, cleaning of all filter, checking of refrigerant gas pressure, checking of all spare parts serviceability, tightening carefully loose connection and re-fixing in same position or different location as directed and making the duct air tight by using foam and other necessary packing materials and testing complete all as specified and as directed. |
| 49 | Taking out water cooler of any capacity from store yard / site to the workshop and dismentle the complete eqpt and carry out necessary mechinary work for complete serviceing & cleaning with water and suitable cleaning agent properly, cleaning of all filter, checking of refrigerant gas pressure, checking of all spare parts serviceability, tightening carefully loose connection and re-fixing in same position or deposted to store yard and testing complete all as specified and as directed. |
| 50 | Taking down desert cooler of any capacity for complete serviceing & cleaning with water and suitable cleaning agent properly, cleaning of all filter, checking of all spare parts serviceability, tightening carefully loose connection and re-fixing in same position or different location as directed and testing complete all as specified and as directed. |
| 51 | Supply and fixing in repair compressor for Refrigerator n. exc 230 Ltr capacity including charging of gas R-134 and anti vibration rubber pad including testing and reinstallation at site or deposited to store yard complete all as specified and directed. |
| 52 | Supply and fixing in repair compressor for Refrigerator of capacity 240 Ltrs above but n. exe. 310 Ltr capacity including charging of gas R-134 and anti vibration rubber pad including testing and reinstallation at site or deposited to store yard complete all as specified and directed. Make - Taccumsha /Whirpool / emersion (Kirloskar)/LG |
| 53 | All as per item No.52 mentioned here in above but for water cooler of any type and capacity, recharging of compressor with gas R-134 complete all as specified and directed. |
| 54 | Supply and fixing in repair rotary compressor for air conditioner window/split type 1.5 Ton capacity including charging of gas up to required level and replacement of anti vibration rubber pad and testing or reinstallation at site or deposited to store yard complete all as specified and directed. |
| 55 | Supply and fixing in repair rotary compressor for air conditioner window/split type 2.0 Ton capacity including charging of gas up to required level and replacement of anti vibration rubber pad and testing or reinstallation at site or deposited to store yard complete all as specified and directed. |
| 56 | Supply , fitting ,testing and commissioning of brass non return valve (NRV) of approved make and suitable size on cold water inlet of geyser to prevent backflow ,including all accessories such as unions ,bend etc complete all as specified and directed. |
| 57 | M&L for repair to body of any type of refrigerator / water cooler including cutting of worn out portion & make good the same, denting, craging of existing paint with existing colour approved paint including testing complete all as directed. |
| 58 | M&L for preparation of existing external surface of Refrigerator / water cooler / deep freezer and applying two coats of synthetic enamel paint over a coat of red oxide primer of approved colour with spray machine painting and writing MES/SM /Sl No complete all as specified and as directed. |
| 59 | Supply and fixing fan motor for window/Split type air conditioner 1.5/2.0 ton capacity complete all as specified and directed. |
| 60 | M&L for taking out and replacement of refrigerator cooling chamber (freezer assembly) complete of existing size, charging of gas up to required level including testing, reinstallation or deposited to store yard complete all as specified and directed. |
| 61 | M&L for taking out and replacement of condenser for refrigerator of any capacity of existing size & dia, including testing compelte all as specified and directed. |
| 62 | M&L for taking out fan motor from water cooler of capacity 20/40 ltrs and replace with new fan motor complete set as per existing size, model including testing complete all as specified and directed. |
| 63 | M&L for taking out fan motor from water cooler of capacity 40/40 ltrs or 40/80 ltrs and replace with new fan motor complete set as per existing size, model including testing complete all as specified and directed. |
| 64 | Supply and fixing in repair and replacement of submersible water pump for desert cooler as per sample approved complete all as specified and directed. (Model SX-8) Make - Bansal. |
| 65 | Supply and fixing in repair and replacement of refrigerator starting Relay/ OLP as per existing size and model complete all as specified and as directed. Make: Danfoss or equivalent as approved complete all as specified and directed. |
| 66 | Supply and fixing in repair and replacement of Refrigerator Thermostat (Single Door) as per existing size and model complete all as specified and as directed. |
| 67 | Supply and fixing in repair and replacement of Refrigerator door lock as per existing size and model complete all as specified and as directed. |
| 68 | Supply and fixing in repair and replacement of refrigerator Ice try as per existing size and model for any capacity of refrigerator complete all as specified and as directed. |
| 69 | Supply and fixing in repair and replacement of relay for air conditioner window/split type of any capacity as per existing size and model complete all as specified and as directed. |
| 70 | Supply and fixing in repair and replacement of thermostat for air conditioner window/split type of any capacity as per existing size and model complete all as specified and as directed. |
| 71 | Supply and fixing in repair and replacement of selector switch for air conditioner window type of any capacity as per existing size and model complete all as specified and as directed. |
| 72 | S&F for replacement of suitable starting relay cum over load (box type) for water cooler as per sample approved complete all as specified and directed. |
| 73 | M&L for taking out exhaust air changer (fan motor) from desert cooler at store yard / site, rewinding with copper wire of existing gauge for three speed & varnishing, heating complete of rewinding and refixing in same positing including testing complete all as specified and directed. |
| 74 | M&L for preparation of existing external and internal surface of desert cooler body and applying two coats of synthetic enamel paint over a coat of red oxide primer of approved colour with spray machine painting complete all as specified and as directed. |
| 75 | S&F in repair and replacement of Capacitor 6 MFD 240 volts AC complete all as specified and as directed. |
| 76 | S&F in repair and replacement of Capacitor 8 MFD 240 volts AC complete all as specified and as directed. |
| 77 | S&F in repair and replacement of Capacitor 36-50 MFD 240 volts AC complete all as specified and as directed. |
| 78 | S&F in repair and replacement of Capacitor 100/120 MFD 240 volts AC complete all as specified and as directed. |
| 79 | S&F in repair and replacement of Capacitor 120/150 MFD 240 volts AC complete all as specified and as directed. |
| 80 | S&F in repair and replacement of Printed Circuit Board (PCB) with remote control and all other accessories suitable for window type air conditioner complete all as specified and as directed. |
| 81 | S&F in repair and replacement of Printed Circuit Board (PCB) with remote control and all other accessories suitable for Split type air conditioner complete all as specified and as directed. |
| 82 | Supply and fixing in repair and replacement of front grill complete set suitable for air conditioner window type of any capacity complete all as specified and as directed.. |
| 83 | Supply and fixing in repair and replacement of fan blade for air conditioner window/split type of any capacity as per existing size and model complete all as specified and as directed. |
| 84 | Supply and fixing in repair and replacement of air conditioner drain pipe window/split type of any capacity as per existing size and model complete all as specified and as directed. |
| 85 | Supply and fixing in repair and replacement of remote control assembly for air conditioner window/split type of any capacity as per existing size and model complete all as specified and as directed. |
| 86 | Supply and filling of poly alky line glycol (PAG) synthetic compressor oil ND-8 after draining & drying existing compressor oil including testing complete all as specified and directed by Engineer-in-Charge. |
| 87 | Supply and Charging of fresh Gas R-134 including testing complete all as specified and directed by Engineer-in-Charge. |
| 88 | Supply, fixing and clamping jointing of copper tubing of size 15 mm for suction line and for liquid discharge line including making hole in wall for passing through and making good the disturbed surface omplete all as specified and as directed. |
| 89 | Supply, fixing and clamping jointing of copper tubing of size 12 mm for suction line and for liquid discharge line including making hole in wall for passing through and making good the disturbed surface omplete all as specified and as directed. |
| 90 | Supply, fixing and clamping jointing of copper tubing of size 10 mm for suction line and for liquid discharge line including making hole in wall for passing through and making good the disturbed surface omplete all as specified and as directed. |
| 91 | Supply and fixing insulation foam material suitable for A/C copper pipe omplete all as specified and as directed. |
| 92 | Supply and fixing wall bracket duly painted for fixing outdoor unit of split type A/C including suitable anchor fastner nuts bolts and washer for fixing bracket complete all as specified and as directed. |
| 93 | S&F in repair and replacement of non return valve for air conditioner window type of any capacity complete all as specified and as directed.. |
| 94 | S&F in repair and replacement of dry filter for air conditioner window/split type of any capacity as per existing size and model complete all as specified and as directed. |
| 95 | S&F in repair and replacement of dry filter for refrigerator of any capacity as per existing size and model complete all as specified and as directed. |
| 96 | M&L for repair and replacement of main burnt transformer of 01 KVA capacity stabilizer with copper winding, wiring and testing complete all as specifed and as directed. |
| 97 | M&L for repair and replacement of main burnt transformer of 0.5 KVA capacity stabilizer with copper winding, wiring and testing complete all as specifed and as directed. |
| 98 | M&L for repair/repalacement defective parts (i.e. relay, electronic circuit plate, 9-0-9 Transformer, fuse MCB, Voltmeter, LED, wiring etc) of stablizer capacity 0.5 / 1.0 KVA and testing complete all as specified and directed. |
| 99 | M&L for repair/repalacement defective parts (i.e. relay, electronic circuit plate, 9-0-9 V/ 12-0-12 V Transformer, fuse MCB, Voltmeter, LED, wiring etc) of stablizer capacity 2.0 / 3.0 KVA and testing complete all as specified and directed. |
| 100 | M&L for repair/repalacement defective parts (i.e. relay, electronic circuit plate, 9-0-9 V / 12-0-12 V Transformer, fuse MCB, Voltmeter, LED, wiring etc) of stablizer capacity 5.0 KVA and testing complete all as specified and directed. |
| 101 | S&F long nose PVC push cock as per sample approved complete all as specified and directed. |
| 102 | S&F flexible pipe for drainage of size 3 / 4\\" as per sample approved complete all as specified and directed. |
| 103 | S&F PVC flexible pipe size 15 mm dia of medium grade as per sample approved complete all as specified and directed complete all as specified and directed. |
| 104 | S&F elbows & distributor (Plastic set of 4) of desert cooler as per sample approved complete all as specified and directed. |
| 105 | S&F suitable size of filter pad (Khas) for desert cooler of any size (set of three) as per sample approved complete all as specified and directed. |
| 106 | S&F in replacement of side panel of desert cooler made out of 24 SWG GI Sheet complete all as specified and directed. |
| 107 | S&F in replacement of water tank depth of minimum 25 mm of desert cooler made out of 24 SWG GI Sheet complete all as specified and directed. |
| 108 | S&F in replacement of top panel of desert cooler made out of 24 SWG GI Sheet complete all as specified and directed. |
| 109 | S&F in replacement of front panel of desert cooler made out of 24 SWG GI Sheet complete all as specified and directed. |
| 110 | S&F of plastic grill of suitable size of existing plastic grill including nuts & bolts etc for desert cooler as per sample approved complete all as specified and directed. |
| 111 | S&F heavy duty rotary switch (4 terminals) complete (rated 15 Amps) for desert cooler (ISI mark) as per sample approved complete all as specified and directed. |
| 112 | S&F two pin metal plug top for AC as per sample approved complete all as specified and directed. |
| 113 | Suplly , insstallation and testing of IDU of air conditiner of capacity 1.5 T complete indoor unit comprising evaporator coil, blower fan washable air filter , insulated condensate drain tray ,high efficiency ,low noise, microprocessor based remote system complete all as specified and directed. |
| 114 | S&F HT connector (Heavy duty) of 3 terminal for 5 KVA stabilizer as per sample approved complete all as specified and directed. |
| 115 | S&F time delay relay (TDR) electronic circuit plate (make Tycon or equivalent) for 5 / 3 / 2 / 1 / 0.5 KVA stablizer complete all as directed. |
| 116 | S&F lamp LED indicator (RYB) incuding holder ans resistance as per sample approved |
| 117 | S&F Transformer (9-0-9 Volt or 12-0-12 Volt) capacity 500 Milli Amps (make Monex/deluxe or equivalent) complete as directed. |
| 118 | S&F relay capacity 25 amps ( Make Dummac) for 3.0 / 5.0 KVA stabilizer complete all as directed. |
| 119 | S&F relay capacity 5 amps (Make Dummac) for 1 / 0.5 KVA stabilizer complete all as directed. |
| 120 | Supply installation and testing of ODU 1.5 TR complete with all accessories ,comprising of hermetically seated compressor , air cooled condensor with copper tube and alluminium fins suitable for operation on 230 V , 50 Hz single phase ac supply using eco friendly refrigirent complete all as specified and directed. |
| 121 | S&F electronic circuit plate of 130 V & 1 / 4 watt resistance for 0.5 / 1.0 KVA stablizer complete all as specified and directed. |
| 122 | S&F electronic circuit plate of 130 V & 1 / 2 watt resistance for 5 / 3 / 2 KVA stablizer complete all as specified and directed. |
| 123 | S&F fuse with holder as per sample of capacity 10 / 15 Amps as per sample approved complete all as specified and directed. |
| 124 | S&F 3 pin 15 Amps plug top complete all as specified and directed. |
| 125 | S&F 3 pin 5 Amps plug top complete all as specified and directed. |
| 126 | Taking down carefully copper / aluminium point wiring (light, fan, switch,socket or power, Bell & Two way point) complete with fitting such as switches, sockets, ceiling rose,sketch light fittings etc, and making good the disturbed surface of walls and floors etc complete all as specified and directed. |
| 127 | Taking down carefully main switches DB's/ MCB DB's and making good the disturbed surfaces of walls etc complete all as specified and directed. |
| 128 | Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed. |
| 129 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling PVC conduit on surface will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes/modular boxes for mounting switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed. |
| 130 | All as per item no 129.00 above but one bell point controlled by one bell Push |
| 131 | All as per item no 129.00 above but one 5 Amps socket out let point controlled by one switch on same board with other switches. |
| 132 | All as per item no 129.00 above but one 5 Amps socket out let point on independent board controlled by one switch. |
| 133 | All as per item no 129.00 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board. |
| 134 | All as per item no 129.00 above but wiring with 4.0 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board. |
| 135 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area drawn in existing concealed conduit and 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes/modular box for mounting switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed.. |
| 136 | All as per item no 135 above but one 5 Amps socket out let point controlled by one switch on same board with other switches. |
| 137 | All as per item no 135 above but one 5 Amps socket out let point on independent board controlled by one switch. |
| 138 | All as per item no 135 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board. |
| 139 | Supply and fixing modular Switch 6 Amps single pole, one way complete all as specified and directed . |
| 140 | Supply and fixing Modular Socket outlet, multi purpose, 5 Pin 6 Amps flush type complete all as specified and directed . |
| 141 | Supply and fixing Modular Switch 16 Amps single pole, one way complete all as specified and directed . |
| 142 | Supply and fixing Modular Socket outlet, multi purpose, 6 pin 16 Amps universal socket complete all as specified and directed . |
| 143 | Supply and fixing in repair Modular Bell push flush type,6 Amps fixed complete all as specified and directed |
| 144 | Supply and fixing Ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. |
| 145 | Supply and fixing in repair modular fan regulator of four step type compatible with BLDC fan complete all as specified and directed . |
| 146 | Supply and fixing in repair white/colour finished single mounting modular plates with inner & outer cover suitable for housing modular accessories suitable for one module box complete all as specified and directed |
| 147 | All as per item no 146 above but suitable for 2 modules |
| 148 | All as per item no 146 above but suitable for 3 modules |
| 149 | All as per item no 146 above but suitable for 4 modules |
| 150 | All as per item no 146 above but suitable for 6 modules |
| 151 | All as per item no 146 above but suitable for 8 modules |
| 152 | Supply and fixing in replacement for 1.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed . |
| 153 | Supply and fix electric water heater,storage type with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete and taking down the old unsv one ,depositing in MES yard for BER complete all as specified and directed. |
| 154 | S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strand 10 sqmm aluminiuam conductor complete all as specified and as directed. |
| 155 | Supply & fixing in repair modular AC box with single pole and neutral with single pole MCB 32 Amps 240 volts fixed in repairs complete. |
| 156 | Supply and fixing in repair Bell multi music type AC 240 Volts,single pole complete all as specified and directed. |
| 157 | Supply, fixing and testing of ceiling fan 1200 mm sweep, heavy duty, single phase, AC, 230 Volts, 50Hz, BEE 5 star rating, ISI marked complete with down rod, canopy, blades, BLDC motor etc and connecting up complete including complete connection from ceiling rose to fan including writing of MES Number with synthetic enamel paint complete all as specified and as directed including taking down old unsv one and deposit in MES store for BER.. . |
| 158 | Supply and fixing in repair modular Switch 6 Amps single pole, one way complete all as specified and directed . |
| 159 | Supply and fixing in repair Modular Socket outlet, multi purpose, 5 Pin 6 Amps flush type complete all as specified and directed . |
| 160 | Supply and fixing in repair Modular Bell push flush type,6 Amps fixed complete all as specified and directed |
| 161 | Supply and fixing in repair Modular Socket outlet, multi purpose, 6 pin 16 Amps universal socket complete all as specified and directed . |
| 162 | Supply and fixing in repair Modular Switch 16 Amps single pole, one way complete all as specified and directed . |
| 163 | Supply and fixing in repair modular fan regulator of four step type compatible with BLDC fan complete all as specified and directed . |
| 164 | Supply and fixing double door TPN DBs four way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and directed . |
| 165 | S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 166 | S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 167 | Supply and fixing MCB SPN 40 to 63 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . |
| 168 | Supply and fixing MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 169 | Supply and fixing MCB TPN 63 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . |
| 170 | Supply and fixing MCB TPN 100 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . |
| 171 | Supply and Fixing wall/surface mounting luminaires integrated LED Batten 20 W, 6500 K , 230V with extruded Aluminium housing 4 feet long with frosted PMMA/PC diffuser & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements all as per specified and directed by Engr-in-charge.. |
| 172 | Supply and fixing wall/surface mounting luminaires (Mirror Light) integrated LED Batten( 2 feet) 10/12 W, 6500 K, 230V ,> 100 lumens/watt,with extruded & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrngements all as per specified and directed by Engr-in-charge |
| 173 | Supply and fixing in repair Wall light fixture lantern made up of nickel finish, Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base., all necessary accessories complete all as specified and directed. |
| 174 | Supply and fixing LED light fitting for bldg security lighting energy saving & environmental friendly long life versatile pressure die-cast housing with individual high power LED as light source and lens embedded PC cover of capacity 35 watt 240 volts AC 50 Hz , IK 07 and IP 66 protection suitable for 40/25 mm dia GI pipe bracket including three years on site warranty from manufacturer complete all as specified and directed. |
| 175 | M & L for security wall light bracket made out of GI pipe light grade 40 mm dia 0.9 metre length bent to shape and reduced to required size at top upto 1.5 metre length by cutting, welding and well finishing including MS clamp of flat iron of size 40x6 suitable length 2 sets complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats of aluminium paints over a coat of red oxide primer including dismantling one complete all as specified and as directed. |
| 176 | S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed.NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire. |
| 177 | S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed.NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire. |
| 178 | M&L for Rigid non metallic PVC conduit ISI marked, medium grade, inclusive of all fitting such as tees,bends. Junction boxes, elbows saddles. Pipe hooks,couples and lock outs etc 25 mm external dia, fixed on surface mounted complete and making good disturbed surfaces in repairs all as directed. |
| 179 | M&L for Rigid non metallic PVC casing caping ISI marked, medium grade,not less than 20mm base size inclusive of all fitting such as tees,bends. Junction boxes, elbows saddles hooks,couples and lock outs etc fixed on surface mounted complete and making good disturbed surfaces in repairs all as directed. |
| 180 | Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy