| 1 | Comprehensive maintenance consisting of fort-nightly examination, testing, adjustment, oiling / lubrication, checking, cleaning, servicing, preventive maintenance, necessary repairs and replacement of defective parts etc., for smooth operation of electrically operated various makes lift 8 / 13 passengers capacity / Goods lift of 1.00 metre per second speed of AC VVV frequency drive with micro processor miconic control with simplex collective selective control system ARD (Auto Rescue Device) in multistorey building to serve ground floor and five upper floors in CABS / STIR / DEBEL / ADE Bangalore including repair / replacement as required of car light LED, call bell, Audio system, fire switch, fire switch glass, car position indicator, car control switch, indicating lamp, door coupler, limit switch, replacement of broken mirror if any, maintenance of all indicators etc and ensuring continuous and effective functioning of lifts. The repair / replacement of defective parts in the lift shall be done by the contractor free of cost within 24 hours of notification for minor / medium rectification and within 72 hours for major rectification complete all as specified and as directed by Engineer-in-Charge. |
| 2 | NOTE :- (i) The rate quoted included necessary repair to ARD (Auto Rescue Device) to make it proper functional. (ii) The contractor shall ensure that no password, passcode or multiple passwords / passcodes are set on any drive, panel, control board, or any other programmable board / equipment without obtaining prior written permission from the Department. In all such approved cases, the contractor must immediately intimate the Department in writing regarding the password / passcode used. (iii) The rates quoted by the contractor shall be deemed to include the complete removal of any type of password / passcode at any level in the lift system or in any of its connected panels, boards, drives, or cards, as required by the Department. |
| 3 | All as per Ser item No. 1.00 above but for OTIS make lift 08 passenger capacity lift G+4 floor at Annexe Building CABS-02 Nos. , Technical building CABS - 01 No. and Admin Block CABS - 01 No. , STIR bldg-01 No. & AEW&C bldg - 01 No. Total - 06 Nos. |
| 4 | All as per Ser item No. 1.00 above but for OTIS make 2500Kg capacity goods lift G+4 floor at Annexe Building CABS and STIR bldg - 01 No. Total lift - 02 Nos |
| 5 | All as per Ser item No. 1.00 above but for OMEGA make 2500Kg capacity goods lift G+2 floor at ADE Complex ,Total lift -01 No |
| 6 | All as per Ser item No. 1.00 above but for OTIS make lift 08 passenger for G+2 floor at ADE Complex ,Total lift -01 No |
| 7 | All as per Ser item No. 1.00 above but for Thyssen krup make lift 08 passenger for G+6 floor at DEBEL complex ,Total lift -01 No |
| 8 | All as per Ser item No. 1.00 above but for Thyssen Krup make lift 15 passenger for G+6 floor at DEBEL Complex ,Total lift -01 No |
| 9 | All as per Ser item No. 1.00 above but for OTIS make lift for 544Kg / 8 passenger capacity lift at CEMILAC to serve for G+3 floor Total lift 01 No |
| 10 | NOTE FOR SL ITEM NO, 1.01 to 1.08 :-1. The contractor shall get inspected all lifts by lift inspector nominated by Chief Electrical Inspectorate of Karnataka and obtain worthi-ness certificate once in the currency of the contract but not later than four months from the date of acceptance of tender without any financial effect.2. Maintenance and repair of all lifts and attending day to day complaints for the mentioned area DRDO Labs all as directed / specified as under:-(a) Nature of duty :-(i) Attending of all day to day complaints of maintenance works. (ii) Lift technician to be present in the area for attending emergency break down. (iii) In case emergency arises, contractor has to be depute their technical person / Engineer to sites in odd hours to repair the defects and resolve the problem.(iv) The complaint needs to be attended within 15 min as received telephonically and necessary safety measures to be carried out if not attended within specified period, then penalty of Rs 500 per hour max to Rs 25000 will be imposed by department per complaint. |
| 11 | (v) Contractor should strictly adhere to the statutory regulation viz minimum wages act, PF act, ESI scheme and other regulation.(vi) In case of delay in attending the complaints in time, department will be at liberty to get the work done through any other contractor and cost may be recovered from the tenderer.(vii) The Lift will be handed over to the contractor in working condition. Any malfunctioning further during the period of contract will be rectified by the contractor. (viii) It is responsibility of the contractor to diagnose the probable defect upon receipt of the complaint, inform the deptt accordingly & carry out satisfactory rectification of defect within prescribed time limit, which shall not exceed 48 hours |
| 12 | Supply and fixing stickers / banners inside the lift with 240 micron 3M Eco Vinyl print with matt finish prevents air bubbles during installation on flat metal surfaces inside lift area with protective overlaminate to prevent scratches from bags or equipment and allows regular cleaning of the lift complete all as specified and as directed. |
| 13 | Supply and fixing in replacement of car door header with door motor, drive, coupler and other accessories for lift of up to G+4 floors including taking down of old unserviceable materials complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Supply and fixing in replacement of landing header centre opening telescopic door of clear dimension of lift up to G+4 floors capacity including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply and fixing in replacement of door drive for lift upto G+4 lift complete including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply and fixing in replacement of door sensor of lift including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Supply and fixing in replacement of Car processing card of G+4 lift including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Supply and fixing in replacement of programming card for ARD with invertor and convertor, double mask, heavy duty. MAKE :- INVT / MABARA / OTIS of G+4, 8/13 passenger lift including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Supply and fixing of Encoder with cable of 8 / 13 passenger / goods lift including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 20 | Supply and fix in replacement of hoist way wiring complete using 0.75 sq.mm copper flexible conductor of 8/13 passenger / goods lift including taking down old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Supply and fix in replacement of copper travelling flexible cable 12 core 0.75 sq.mm of 60RM including taking down of old unserviceable complete all as specified and as directed by Engineer-in-Charge. |
| 22 | Supply and fixing in replacement of V3F microprocessor closed loop full collective operation controller with features like ARD, overload device, automatic self levelling alarm bell, 7 segment display and voice annunciator complete all as specified and as directed by Engineer-in-Charge. |
| 23 | Supply and fixing in replacement of over Speed Governor unit complete with tension pit pulley 1 mps, tripping speed 1.3 mps including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Supply and fix in replacement of main iron rope 13mm dia of superior quality ISI marked of 96 RM for G+4, 8/13 passenger / goods lift including taking down old unserviceable one complete all as specified and as directed by Engineer-in-Charge. |
| 25 | Supply and fixing in replacement of car operating panel upto G, 1, 2, 3, 4 (5th floor) Flush type Stainless Steel DC stop, alarm light, fan switch, up and down arrow, digital position indicator, fixing , testing and taking down the unserviceable complete all as specified and as directed by Engineer-in-Charge consisiting of the following:- |
| 26 | a) Alarm button shall be provided with a yellow pictogram to indicate the alarm button provision. b) Fan / blower switch, Door open, Door Close button.c) The main floor / exit floor push button, protruded 5mm beyond the other floor buttons. d) \\"Up\\" & \\"Down\\" direction indicators indicating travel direction.e) Key operated switch for \\"attendant\\" and \\"Automatic\\" operation.f) Overload panel along with audio/visual direction.g) Door hold button, which extends normal door open period by up to 30 seconds. The extended time can be cancelled by actuation of door close button.h) 16 segment type LED based / scrolling digital car position indicator with LED/LCD illumination indicating the landing at which the car is stopped or passing.j) Hall buttons combined with digital position indicator with SS hairline finish face plate suitable for simplex full collective operation of lobby floor of all landings. (G+4 floor) |
| 27 | Material and labour in replacement of main gear box and pedestal, shifting to the factory, grid the worn out gear shaft, make a new pedestal bush bearing according to the gear shaft size, press the bush bearing with hydraulic press, shift the gear to the site from factory, fix and align the gear box, adjust the pedestal and gear shaft and replace the gear oil and run the lift complete all as specified and as directed by Engineer-in-Charge. |
| 28 | Supply and fix in replacement of V3F main drive suitable for 11 KW Motor including taking down old one complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Supply and fix in replacement of main sheave 530mm dia 5 groove for 13mm dia rope suitable for G+5, pressing hydraulically and testing for smooth functioning of the lift complete all as specified and as directed by Engineer-in-Charge. |
| 30 | Material and labour for replacement of landing push button with call register button with stainless steel face plate, fixing connection and testing, and taking down the existing land push buttons complete all as specified and as directed. |
| 31 | Material and labour for replacement of landing push button with call register button with stainless steel face plate, fixing connection and testing and taking down the existing land push buttons complete all as specified and as directed. |
| 32 | Supply and fixing in replacement of landing push button with call register button with stainless steel face plate, fixing connection and testing and taking down the existing land push buttons complete all as specified and as directed by Engineer-in-Charge. |
| 33 | Material and labour for replacement of landing push button with call register button with stainless steel face plate, fixing connection and testing and taking down the existing land push buttons (set of seven) complete all as specified and as directed. |
| 34 | Supply and fixing in replacement of ARD Battery Charging card Heavy Duty for G+4, 8/13 passenger lift including taking down of old unserviceable one complete all as specified and as directed. MAKE : INVT / MABARA / OTIS |
| 35 | Supply and fixing in replacement of ARD Battery for G+4, 8/13 passenger lift including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge. MAKE : EXIDE / KIRLOSKAR |
| 36 | Supply, fabricate, and fix heavy-duty anti-skid floor mat of minimum 10 mm thickness, made of approved quality rubber material, with non-slip textured surface of suitable size complete in all respects as per specifications and as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 37 | Supply, fabricate, and fix heavy-duty anti-skid floor mat of minimum 10 mm thickness, made of approved quality rubber material, with non-slip textured surface of suitable size complete in all respects as per specifications and as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |