| 1 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level), complete all as specified and directed. |
| 2 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons laid bedded , dry and pointed etc, complete all as specified and directed. |
| 3 | M & L sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed by Engineer-in-charge . |
| 4 | Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor topping, 75 mm thick, complete all as specified and directed. |
| 5 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 with grey cement and pigment complete all as specified and directed. Note :- The colour of tiles Red/Yellow approve by Engr -in -charge. |
| 6 | M&L for preparation of old painted surfaces brick, stone, concrete or plaster surafces of any description not otherwise described, over 10 cm width or girth, applyinng 2 coats of synthetic enamel paint of approved shade all as specified and directed by Engr-in-charge. |
| 7 | All as per item no-05, but except tiles, complete all as specified and as directed. |
| 8 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed. |
| 9 | M&L for providing cement concrete type B1 1:2:4 (20mm graded aggregate) as copings, kneelers, apex stones, bed plates, kerbs, edge of paver block , water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed |
| 10 | M&L for Chequered cement concrete tiles (coloured) 300mmX 300mmX25 mm thick thick heavy duty, chmecially treated Chequred/pavement tiles of size and shape as approved over 15mm thick screed bed in CM 1:6, set and jointed in neat cement siurry and pointed with grey cement mixed complete all as specified and directed. Note :- The colour of tiles Red/Yellow approve by Engr -in -charge. |
| 11 | M&L for preparation of new or previously untreated surface brick, stone, concrete or plaster surafces of any description not otherwise described, over 10 cm width or girth, applyinng 01 coats of synthetic enamel paint of approved shade all as specified and directed by Engr-in-charge. |
| 12 | Dismantling of brick work built in cement mortar of any specification and in any position, complete all as specified and directed. |
| 13 | M & L brick work with sub class ‘B’ old sized bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 14 | All as per item 13 hereinbefore but using old bricks retrieved from demolition under item 10 hereinbefore including cleaning and removal of mortar from old bricks, complete all as specified and directed. |
| 15 | Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 16 | Rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:4 finished even and smooth without using extra cement, complete all as specified and directed. |
| 17 | M&L for preparing newly plastered surface and applying two coats of cement base paint on wall surfaces, complete all as specified and directed. |
| 18 | M & L for preparing old surfaces and applying one coat of cement based paint on wall surfaces, complete all specified and directed. |
| 19 | M &L Broken glass coping on top of wall in cement mortar1:3, complete all as specified and directed. |
| 20 | Dismantling fencing wire mesh, any type, complete all as specified and directed. |
| 21 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed gound, complete all as specified and directed. |
| 22 | Excavating in post holes (or similar holes) each n exc 0.5 cu. M, getting out, returning, filling in and raming earth or broken , in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, complete all as specified and directed. |
| 23 | M&L posts and struts for fencing and other steel section including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0, complete all as specified and directed. |
| 24 | S&F galvanised 2 strand barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to Angle iron post, complete all as specified and directed. |
| 25 | Preparation of New steel surfaces of any description and in any position over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified and directed. |
| 26 | M&L painting to old steel surfaces of any description, over 10cm width or girth in one coat with synthetic enamel paint including preparation of surfaces, complete all as specified and directed. |
| 27 | M & L plain cement concrete for nominal mix type( B-1) 1:2:4 using 20mm graded stone aggregate in plinth course,plinth band and similar work including necessary form, complete as as specified and directed. |
| 28 | Mild steel tmt bars 8 mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips, complete all as specified and directed. quality conforming to |
| 29 | M/L Plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed. |
| 30 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard rails, straining bolts etc including provn of binding wire, complete all as specified and directed. |
| 31 | Supply only chain link MS galvanated fencing any size fixed to any type of stander rail n exc 3 kg per sqm, complete all as specified and directed. |
| 32 | M&L for Cement concrete 1:2:4 type B-2 using (40mm crushed graded stone aggregate) 75mm thick as in floor, finished top surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 33 | Dismantling Asbestos cement/GI (corrugated, semi corrugated, etc) ) sheets in on roof coverings, complete all as specified and directed. |
| 34 | M & L Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 35 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 36 | S&F rolled mild steel channel, angle as in purline, rafter & vertical type etc on roof cutting to dead length where required and welding to each other complete all as specified and as directed. |
| 37 | Supply and fixing hard drawn steel wire fabric not exc 4 kg/sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 38 | Dismantling floor, hearth or wall tiling including cement mortar beding (but not backing),removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 39 | S&F Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in flooring etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with colour of tiles over and incl screed bedding 15mm thick in cm(1:6), complete all as specified and directed. |
| 40 | All as per item No 39 here-in-before but as in skirting over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 41 | M&L for Glazed ceramic tiles, coloured (colour as approved), of size 450x300x7mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 10mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles, complete all as specified and directed. |
| 42 | M&L for cement concrete type B2 1:3:6 (40mm graded aggregate) in surface channels and drains complete all as specified and directed by Engineer-incharge. |
| 43 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete , using extra cement , including forms , moulds, mitred/ stopped ends etc. complete all as specified and directed. |
| 44 | Racking out joints/pointing to brick work in walls or bricks on edge in floors, surface channel, roofs etc. and flush pointing to brick walls in cement mortar (1:3) complete all as specified and directed by Engineer-in-charge. |
| 45 | Mild steel framed work of Fe-410-0 or Fe-310-0 (Fe-290 Gde-E-165) as in doors or gate of angle or other section with gusset plates,rails, braces etc and fixing, complete all as specified and directed. Please Enable Macros to View BoQ information |