| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:Executing Agency, NWM&M, HQ IDS Name of Work :Special Repair to Wall wash Lights and Allied Works at National War Memorial & Museum. Contract No: PD/EANWMM/……./2026-2027 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking out old unsv/ existing exterior reccessed built into platform/ground any make and modol including wiring, housing, driver and fiiting accessories arrangement complete all as specified and directed by Dy project Director. |
| 3 | Supplying, Installing, Testing and Commissioning Exterior Recessed Ground Mounted 20 W / running metre LED Wall Wash Distribution Uplight fixture with Housing Box of die cast aluminium, die cast aluminium trim, frosted glass optics, installation cover and other necessary accessories, frosted lens with and including 20 Watt LED lamps suitable for the fixture and also including the mounting and fixing accessories and arrangements and also complying with the following requirements / specifications all as specified and as directed by Dy Project Dir: -(a) Lamp Type : 20 Watt LED (b) Fixture Wattage : 20 Watt (c) Lumen Efficacy : 85 Lumens / Watt (d) CCT / CRI : 3000 K / + 80 (e) Optical Distribution : Wall Wash Distribution (f) Voltage : 230 V AC (g) Type of Control Gear : Integral Electronic Driver (h) Control Type : Dimmable (j) I.P. Rating : IP-67 (k) Size : Length (1200/1000/900/800/600) mm, Width 85 mm, Depth 125 mm or of the size as approved by Dy Project Dir.Note :- The rate quoted shall also be deemed to include for material and labour and all other incidental charges required for fixing and mounting arrangements for the fixture including recessing and other civil works as per manufacturer's design and specifications and requirements and also as per site conditions as approved by Dy Project Dir. |
| 4 | Supplying, Laying, Testing and Commissioning in repair Wiring for circuit/submain wiring alongwith earth wire the 2x2.5 sq. mm +1x1.0 sq. mm earth wire sizes of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required complete all as specified and as directed by Dy project Director. |
| 5 | Dismantling stone slab/ tile of any description/thickness in any position laid wet/ dry as in floor/ wall/coping bedded and pointed in cement mortar complete all as specified and as directed by Dy Project Director. |
| 6 | Material and Labour, in repairs, granite tile flooring using 20/22 mm thick flamed granite tiles (of any type), machine cut (Straight/radial), bedded and jointed in cement mortar (1:3) with grey cement and pointed with to laticrete steller grout to match the shade of granite stone complete and also including all cutting and waste; size of slab /tile and pattern of laying as per existing complete all as specified and as directed by Dy Project Director. Note:- Screed bed shall be measured and paid separeately. |
| 7 | Demolition cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complee all as specified and as directed by Dy Project Dirctor. |
| 8 | S&F in repairs, Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes for posts conforming to I.S.1161-1979 GRADE SE.- 240 complete all as specified and as directed by Project Director. |
| 9 | S&F in repairs, plates (plain or chequered) channels, square cut or noched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde-E-250) quality-A, incl cutting in flooring to make good, complete all as specified and as directed by Dy Project Dirctor |
| 10 | M&L in repairs, PCC type B-1 (1:2:4) using 20mm graded stone aggregate as in post holes & slightly rounded, ramp or chamfered angle fast, bed plasted and the like with smooth finishes, & incl use and waste of form work etc levelling course in depressed / undulation portionson etc on floor complete all as specified and directed by Dy Project Director. |
| 11 | M&L Preparation of painted to new surfaces of any description over 10 cm width or girth and applyin Two coats of first quality synthetic enamel paint on Steel surfaces complete, all as specified and as directed by Project Director. |
| 12 | S&F in repairs, for stainless steel grade 304 frame for framed Structure, Tublar Pipe, Plates, Ornamental Shapes, and similar works including all necessary cutting, fixing in shape & size, welding grinding, Polishing and other similar work & acessories, complete all as specified and as directed by Dy Project Director. |
| 13 | M&L in repair, screed bed or bedding layer 20 mm thick of cement mortar 1:4 for laying any size, shape & thickness of granite stone complete. All as specifed and as directed by Dy Project Director. |
| 14 | Note: An amount of Rs. 39,800.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |