| 1 | M & L for opening up short circuited / winding burnt electric induction motors of 5 to 7.5 HP capacity 3 phase AC 440 Volts, cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper conductor wires of same gauge and size suitable as per the existing including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified. Note - (i) Intimation for any unserviceable motor of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 100/- per hour for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted. |
| 2 | All as per item No. 1 here in before but induction motor of 10 to 12.50 HP capacity 3 phase AC 440 Volts, complete all as specified. |
| 3 | All as per item No. 1 here in before but induction motor of 15 to 20 HP capacity 3 phase AC 440 Volts, complete all as specified. |
| 4 | All as per item No. 1 here in before but induction motor of 40 HP capacity 3 phase AC 440 Volts, complete all as specified. |
| 5 | All as per item No. 1 here in before but induction motor of 60 HP capacity 3 phase AC 440 Volts, complete all as specified. |
| 6 | All as per item No. 1 here in before but induction motor of 90 HP to 100 HP capacity 3 phase AC 440 Volts, complete all as specified. |
| 7 | S & F terminal connector of 5 to 30 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed. |
| 8 | S & F terminal connector of 40 to 100 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed. |
| 9 | S & F of PVC fan blade for motors of 5 to 15 HP capacity complete all as specified. |
| 10 | S & F MS pump motor coupling of 15 HP to 30 HP as per the existing size and shape for pump sets |
| 11 | S & F MS pump motor coupling of 40 HP to 100 HP as per the existing size and shape for pump sets |
| 12 | M & L for motor end ball / roller bearing with good quality grease suitable for 5 HP to 15HP capacity pump sets |
| 13 | M & L for motor end ball / roller bearing with good quality grease suitable for 15 to 40 HP capacity pump sets |
| 14 | M & L for motor end ball / roller bearing with good quality grease suitable for 60 to 100 HP capacity pump sets |
| 15 | S & F rubber bush/belt coupling (set of 8) for motor 15 to 30HP complete all as specified and directed. |
| 16 | S & F rubber bush/belt coupling (set of 8) for motor 40 HP to 60HP complete all as specified and directed. |
| 17 | S & F rubber bush/belt coupling (set of 8) for motor 90 to 100 HP complete all as specified and directed. |
| 18 | M & L for dismantling and taking up/down u/s centrifugal pump sets of any capacity of any size from foundations/pumphouse after disconnecting electric & water connections and transportation from site to contractor's workshop for carrying out repairs to pump sets , replacement of unserviceable parts as required incl re-assembling, re-fixing in position, including connecting in original position & testing complete as directed and specified . Note - (i) Spares required to be replaced will be measured and paid separately. (ii) Intimation for any unserviceable pump of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor or pump will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 100/- per hour for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted. |
| 19 | Supply and fix coupling key any size as per sample for pumping sets of different capacities complete all as directed and specified |
| 20 | M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 5 HP to 12.50 HP capacity complete all as directed and specified |
| 21 | M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 15 to 30 HP capacity complete all as directed and specified |
| 22 | M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 40 HP to 60 HP capacity complete all as directed and specified |
| 23 | M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 90 to 100 HP capacitycomplete all as directed and specified |
| 24 | M & L for carrying out replacement of pump impeller of 5 HP to 7.5 HP capacity complete all as directed and specified |
| 25 | M & L for carrying out replacement of pump impeller of 10 HP to 30 HP capacity complete all as directed and specified |
| 26 | S & F in replacement of gun metal bush complete set of two as per sample for centrifugal pump set 15 HP to 30 HP complete all as directed and specified |
| 27 | S & F in replacement of gun metal bush complete set of two as per sample for centrifugal pump set 40 HP of 100 HP complete all as directed and specified |
| 28 | S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 15 HP to 30 HP complete all as directed and specified |
| 29 | S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 40 HP to 60 HP complete all as directed and specified |
| 30 | S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 90 HP to100 HP complete all as directed and specified |
| 31 | S & F in replacement of pump end ball bearing suitable for 15 HP To 30 HP complete all as directed and specified |
| 32 | S & F in replacement of pump end ball bearing suitable for 40 HP to 60 HP complete all as directed and specified |
| 33 | S & F in replacement of pump end ball bearing suitable for pump sets 90HP to100 HP. complete all as directed and specified |
| 34 | S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 15 HP to 30 HP capacity complete all as directed and specified |
| 35 | S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 40 HP to 60 HP capacity complete all as directed and specified |
| 36 | S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 100 HP capacity complete all as directed and specified |
| 37 | S & F in replacement gun metal impeller single acting suitable for 15 HP capacity. complete all as directed and specified |
| 38 | S & F in replacement gun metal impeller single acting suitable for 30 HP capacity complete all as directed and specified |
| 39 | S & F in replacement gun metal impeller single acting suitable for 40 HP capacity.complete all as directed and specified |
| 40 | S & F in replacement gun metal impeller single acting suitable for 60 HP capacity complete all as directed and specified |
| 41 | S & F in replacement gun metal impeller single acting suitable for 100 HP capacity complete all as directed and specified |
| 42 | M&L for taking out defective submersible pumping set of discharge capacity varying from 4000 to 12000 GPH from bore wells / shallow wells including dismantling and taking out column pipes of any bore & length alongwith submersible cable, steel wire rope etc; and re-lowering the pump set after carrying out necessary repairs / replacement of defective parts all as specified and directed. Note :- i) Costs of all necessary T&P and manpower required at site and transportation is deemed to be included in the rates quoted. |
| 43 | M&L for carrying out repair to submersible pump of 4000 to 12000 GPH capacity after dismantling the assembly for replacement of worn out spares such as stage bowls, impellers, pump shaft, sleeves, bushes etc; incl filling, turning & polishing works to pump shaft, GM impellers as necessiated, reassembling the pump after repairs and testing complete incl applying a coat of water proof epoxy paint to the external surfaces of pump all as specified and directed. Note:-(i) Intimation for any unserviceable pump of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor or pump will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 100/- per hour for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (ii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted. |
| 44 | S & F GM impellers with key and bushes suitable for 4000 to 12000 GPH capacity |
| 45 | S & F pump shaft stainless steel suitable for 4000 to 12000 GPH capacity |
| 46 | S & F non return valve for pump suitable for 4000 to 12000 GPH capacity |
| 47 | S & F bush for pump set suitable for 4000 to 12000 GPH capacity |
| 48 | S & F bowl assembly complete with stage bolts suitable for 8000 to 12000 GPH capacity |
| 49 | S & F neck rings for pump sets of any capacity |
| 50 | S & F stage bowl bush GM suitable for pump sets of any capacity |
| 51 | S & F distance sleeve suitable for pump sets of any capacity |
| 52 | M&L for water proof 'M' seal cable jointing kit with hardner compound, copper ferrule, sleeves, cotton / insulation tape and all materials complete suitable for submersible cable PVC insulated and sheathed, 6 to 10 sqmm flat, 3 core, 1100 volt grade complete all as specified and directed. |
| 53 | M&L for rubber gasket packing, 4 mm thick suitable for 50/80/100/200 mm dia flanged column pipes complete all as specified. |
| 54 | M & L for rewinding of submersible motors AC, 3 phase, 440 volt 10 to 15 HP with superior quality PVC insulated copper winding wire of identical gauge & specification of the existing short circuited winding wires with all necessary insulating materials incl cleaning of stator & slots and applying one coat of water proof epoxy paint to the exteriors of motor and testing complete all as specified on load of capacity. Note :- Any spares other than specified in the item will be measured and paid separately. (ii) Intimation for any unserviceable pump of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 100/- per hour for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted. |
| 55 | M&L for repairs to rotor assembly of submersible motor of any size/make incl cutting & cleaning of defective copper strips from rotor slots, filling cavities, gas welding/bracing and finishing complete all as specified. |
| 56 | S & F motor bush upper and lower 4 to 15 HP for submersible motor complete all as specified. |
| 57 | S & F rotor bearing sleeve upper and lower suitable for submersible motor of any size/capacity complete all as specified. |
| 58 | S & F sand guard suitable for submersible pump set any size/capacity complete all as specified. |
| 59 | S & F motor thrust bearing assembly complete suitable for 4 to 15 HP complete all as specified. |
| 60 | S & F motor housing upper suitable for 4 to 15 HP complete all as specified. |
| 61 | S & F motor housing lower suitable for 5 to 15 HP complete all as specified. |
| 62 | S & F motor coupler sleeve with key suitable for submersible pump sets of any capacity. |
| 63 | S & F in replacement of DOL starter in sheet metal enclouser suitable for 5 HP to 7.5 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 9-14A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. |
| 64 | S & F in replacement of FASD starter in sheet metal enclosure suitable for 10 HP to 15 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 13-21A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length, shape and supporting for SCADA System duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. |
| 65 | S & F in replacement of FASD starter in sheet metal enclosure suitable for 20 HP to 30 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 20-32A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length, shape and supporting for SCADA System drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. |
| 66 | S & F in replacement of cast iron sluice valve of 80 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with high tensile SS spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed.Note:- Any damage made to pipe lines, over head reservoir while replacing the sluice valve will be repaired by contractor on his own cost. Make:-Kirloskar/leader/upadhayay/santNote:- Contractor will be intimated to replace the deffective sluice balve on telephonically followed by in written. Contractor has to arrange new sluice valves and complete the replacement work with 48 hrs after intimation failing which a penal recovery of Rs 400/- per hour will be charged from his payment. Contractor has to keep all required size sluice valve and T&P with manpower ready for fixing on urgent requirment and quote his rates accordingly. |
| 67 | All as per Srl item No. 66 here-in-before but 100 mm dia bore |
| 68 | All as per Srl item No. 66 here-in-before but 150 mm dia bore |
| 69 | All as per Srl item No. 66 here-in-before but 200 mm dia bore |
| 70 | All as per Srl item No. 66 here-in-before but 250 mm dia bore |
| 71 | All as per Srl item No. 66 here-in-before but 300 mm dia bore |
| 72 | S & F in replacement of gun metal gate valves of size 15 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/S gate valves all as specified and directed |
| 73 | Description as per item No 72 here in before but 20 mm bore |
| 74 | Description as per item No 72 here in before but 25 mm bore |
| 75 | Description as per item No 72 here in before but 40 mm bore |
| 76 | Description as per item No 72 here in before but 50 mm bore |
| 77 | Supply only following items for various water supply installations :- |
| 78 | (a) Nylon braided PVC flexible pipe, heavy duty 25 mm dia.all as per sample |
| 79 | (b) Chlorine test kit with coloured sample complete with all testing fitments and 100 ml OT solution in rexine finish wooden box all as per sample.Make:-Aquajio technologies or equilent approved make |
| 80 | (c) Ortho tholodine solution in 500 ml bottle. |
| 81 | (d) Crystal Alum (Ferric) |
| 82 | (e) Crystal Alum (Potassium) |
| 83 | (f) Copper Sulphate |
| 84 | S&F in replacement PVC flexible corrugated pipe of size 40mm bore for suction sweeper as per sample complete all as directed and specified. |
| 85 | S & F in replacement of motor starter of capacity upto 100 HP motor, 3 phase 415 volt with comprehensive motor protection, programmable over load protection, built-in RTD & Thermistor inputs with constant current adaptive accelaration & de-accelaration for smooth start and stop operation of motor incl dismantling of u/s starter & installation / programming by skilled technician of original manufacturer, incl necessary mounting arrangement on existing panel such as fastener nuts & bolts and also fixing HRC fuse of suitable length, shape and Starter supporting for SCADA System capacity on panels with copper busbars etc as required complete all as specified and directed. Make : L&T Cat No EMX3-0255B-411or any equivalent models of approved make |
| 86 | Supply only Calcium Hypochlorite 65% to 70% chlorine content in packed with 45 Kg each drum (calcium based granular disinfectant for water treatment much more stable than chlorine gas and stronger than bleaching powder & sodium hypochlorite complete all as specified and directed. Make : Aquafit or equivalent as approved by NMPT committee of E-in-C's Branch.Note :-The contractor must submit the COC (Certificate of Compliance) in original from manufacturer by All India Authorised MES Distributor for each batch of product delivered indicating and including Chemical Analysis Report by All India Authorised MES Distributor. Note :- 1. The contractor must submit the COC (Certificate of Compliance) in original from manufacturer for each batch of product delivered including chemical analysis report. Contractor has to get approval of Accepting officer before placing purchase order . |
| 87 | S & F cast iron foot valves with flanged end in replacement 80 mm bore all as per including necessary rubber gasket, MS nuts, bolts, washers etc of suitable size complete all as specified and directed. Make:-Kirloskar/leader/upadhayay/santNote:- Contractor will be intimated to replace the deffective foot vavle on telephonically followed by in written. Contractor has to arrange new foot valves and complete the replacement work with 48 hrs after intimation failing which a penal recovery of Rs 400/- per hour will be charged from his payment. Contractor has to keep all required size foot valve and T&P with manpower ready for fixing on urgent requirment and quote his rates accordingly. |
| 88 | All as per item No 87 here in before but foot valves with flanged end in replacement 100 mm bore all l as directed and specified . |
| 89 | All as per item No 87 here in before but foot valves with flanged end in replacement 150 mm bore all l as directed and specified . |
| 90 | All as per item No 87 here in before but foot valves with flanged end in replacement 200 mm bore all as directed and specified . |
| 91 | S & F in replacement of MCCB, 3 Pole, 630Amps 415 Volt AC, 50 Hz, rupturing capacity 50 KA with adjustable thermal and fixed magnetic tripping systems against over load and short circuit conditions conforming to IS:13947 (Part-2) Ics = 100%ICU all as directed and specified . Make : Havells/ L&T/ Standard / LEGRAND/Schneider/Indo Asian. |
| 92 | All as per item No 91 here in before but MCCB of capacity 400 Amps 36 KA all l as directed and specified . |
| 93 | All as per item No 91 here in before but MCCB of capacity 250 Amps 36 KA all l as directed and specified . |
| 94 | All as per item No 91 here in before but MCCB of capacity 200 Amps 36 KA all l as directed and specified . |
| 95 | All as per item No 91 here in before but MCCB of capacity 125 Amps 25 KA all l as directed and specified . |
| 96 | All as per item No 91 here in before but MCCB of capacity 100 Amps 16 KA all l as directed and specified . |
| 97 | M & L for submersible cable, flat PVC insulated and sheathed, 3 core, 6 sqmm, multistranded copper conductor, 1100 volt grade, conforming IS-694, heavy duty complete all as specified and directed. Make - Havells/Gloster/Asian/Universal/Polycab/Finolex |
| 98 | All as per item 92 but cable of size 3 core, 10 sqmm, multistranded copper conductor, 1100 volt grade, heavy duty. |
| 99 | Supply, installation, testing and commissioninng of monoblock pump sets, suitable for pumping water 8 to 18 LPS discharge at 51 m head (not less than 3 HP), IP 55, cast iron body with gun metal/bronze impellers including fixing of safety valve, pressure guage and priming valve etc direct coupled suitable for operation on 3 phase, 415 V, AC, 50 Hz and mounted on channel iron base frame including nut, bolts & washers etc. Note : Old pump will be deposited to AGE E/M store yard by the contractor. |
| 100 | Supply, installation, testing and commissioninng of monoblock pump sets, suitable for pumping water 8 to 18 LPS discharge at 51 m head (not less than 3 HP), IP 55, cast iron body with gun metal/bronze impellers including fixing of safety valve, pressure guage and priming valve etc direct coupled suitable for operation on single phase, 230 V, AC, 50 Hz and mounted on channel iron base frame including nut, bolts & washers etc. Note : Old pump will be deposited to AGE E/M store yard by the contractor. |
| 101 | S & F in replacement of DOL starter in sheet metal enclouser suitable for 3 HP Monoblock motor, 3 phase 440 volt complete with over load protection & adjustable relay range 9-14A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. |
| 102 | S & F in replacement of DOL starter in sheet metal enclouser suitable for 1 HP to 3 HP Monoblock/Submersible pump motor, single phase 440 volt complete with over load protection & adjustable relay range 9-14A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. |
| 103 | M&L for MS Fabrication work, made out of structural steel sections as in frame work for cable & piping ducts / MS door panels etc at water supply installations, MS angles / flats / plain sheets of appropriate gauge, cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shape or sizes as required including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed. |
| 104 | M&L for MS Fabrication work, made out of structural steel sections as in frame work for cable & piping ducts / MS door panels etc at water supply installations, MS angles / flats / plain sheets of appropriate gauge, cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shape or sizes as required including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed. |