| 1 | The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-Budaun Approx. distance upto 0-20 Km. Including safe loading and unloading. |
| 2 | LT XLPE Cable 3.5 X 400 sqmm. |
| 3 | LT XLPE Cable 3.5 X 240 sqmm. |
| 4 | LT XLPE Cable 3.5 X 120 sqmm. |
| 5 | LT XLPE Cable 3.5 X 70 sqmm. |
| 6 | LT XLPE Cable 3.5 X 50 sqmm. |
| 7 | The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom). |
| 8 | AL Busbar having size 10x35x800 mm (A/B Type Pannel Busbar) |
| 9 | AL Busbar having size 10x25x600 mm (A/B Type Pannel Busbar) |
| 10 | AL Busbar having size 6x25x300 mm (C Type Pannel Busbar) |
| 11 | Aluminium Lugs of size 630 sqmm |
| 12 | Aluminium Lugs of size 400 sqmm |
| 13 | Aluminium Lugs of size 240 sqmm |
| 14 | Aluminium Lugs of size 120 sqmm |
| 15 | Aluminium Lugs of size 70 sqmm |
| 16 | Aluminium Lugs of size 50 sqmm |
| 17 | Aluminium Lugs of size 16 sqmm |
| 18 | Aluminium Lugs of size 10 sqmm |
| 19 | Aluminium Lugs of size 6 sqmm |
| 20 | LT underground 3.5cx400 sqmm Repair fault cable by digging trench with the help of road cutter/digging machine/mannual etc. Size of treach x1.5 m, width and up to depth of cable exposing the fault cable preparing the cable, filling cable jointing kit, High pressuer testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contrator as it was in earlier conditions including laying additionals cable if nessesary for cable jointing if loop is not available (All material shall be provided by the contractor & cable fault located by Contractor with fault locator machine of the contractor itself) |
| 21 | LT underground 3.5cx240 sqmm Repair fault cable by digging trench with the help of road cutter/digging machine/mannual etc. Size of treach x1.5 m, width and up to depth of cable exposing the fault cable preparing the cable, filling cable jointing kit, High pressuer testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contrator as it was in earlier conditions including laying additionals cable if nessesary for cable jointing if loop is not available (All material shall be provided by the contractor & cable fault located by Contractor with fault locator machine of the contractor itself) |
| 22 | LT underground 3.5cx120 sqmm Repair fault cable by digging trench with the help of road cutter/digging machine/mannual etc. Size of treach x1.5 m, width and up to depth of cable exposing the fault cable preparing the cable, filling cable jointing kit, High pressuer testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contrator as it was in earlier conditions including laying additionals cable if nessesary for cable jointing if loop is not available (All material shall be provided by the contractor & cable fault located by Contractor with fault locator machine of the contractor itself) |
| 23 | LT underground 3.5cx70 sqmm Repair fault cable by digging trench with the help of road cutter/digging machine/mannual etc. Size of treach x1.5 m, width and up to depth of cable exposing the fault cable preparing the cable, filling cable jointing kit, High pressuer testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contrator as it was in earlier conditions including laying additionals cable if nessesary for cable jointing if loop is not available (All material shall be provided by the contractor & cable fault located by Contractor with fault locator machine of the contractor itself) |
| 24 | LT underground 4x50 sqmm Repair fault cable by digging trench with the help of road cutter/digging machine/mannual etc. Size of treach x1.5 m, width and up to depth of cable exposing the fault cable preparing the cable, filling cable jointing kit, High pressuer testing of cable leveling the road with sand/brick/soil as per norms and leveling of road with contrator as it was in earlier conditions including laying additionals cable if nessesary for cable jointing if loop is not available (All material shall be provided by the contractor & cable fault located by Contractor with fault locator machine of the contractor itself) |
| 25 | By Digging of Trench and Laying of L.T. KV XLPE Cable size 3.5x400 sq mm against damaged cable and leveling the digged trench upto ground level where the old underground L.T. cable fault is not repairable/traceable. Complete in all respect as per RESSPO Norms. |
| 26 | By Digging of Trench and Laying of L.T. KV XLPE Cable size 3.5x240 sq mm against damaged cable and leveling the digged trench upto ground level where the old underground L.T. cable fault is not repairable/traceable.including laying additionals cable if nessesary for cable Laying Complete in all respect as per RESSPO Norms. |
| 27 | By Digging of Trench and Laying of L.T. KV XLPE Cable size 3.5x120/150 sq mm against damaged cable and leveling the digged trench upto ground level where the old underground L.T. cable fault is not repairable/traceable. Complete in all respect as per RESSPO Norms. |
| 28 | By Digging of Trench and Laying of L.T. KV XLPE Cable size 3.5x70/50 sq mm against damaged cable and leveling the digged trench upto ground level where the old underground L.T. cable fault is not repairable/traceable. Complete in all respect as per RESSPO Norms. |
| 29 | CC Road and Interlocking Road Restoration works and bring it to original position (All required material shall be provided by the contractor for execution of work). |
| 30 | Repairing & Replacement of A, B Type boxes ,Pannel doors & tillted/damage mounting angle with Grouting & Foundation. |
| 31 | Repairing of A Type LT DB Pannel Doors (A type box having door spacification 700x2000 Sq mm and 900x2000 sq mm, A Box having door spacification 700x1650 Sq mm and 900x 1650 Sq mm with handle and locking arrangement & Repairing of Damaged mounting angle with Grouting & Foundation of AType boxes (All material shall be provided by the contractor ) |
| 32 | Repairing of B Type LT DB Pannel Doors (B type box having door spacification 750x1500 Sq mm and 400x1500 sq mm, B Box having door spacification 900x1000 Sq mm with handle and locking arrangement ) & Repairing of Damaged mounting angle with Grouting & Foundation of B Type boxes (All material shall be provided by the contractor) |
| 33 | Repairing of C Type LT DB Pannel Doors, handle and locking arrangement Repairing of Damaged mounting angle with Grouting & Foundation of C Type boxes (All material shall be provided by the contractor & cable fault located by Contractor) |
| 34 | Replacement and fixing of following AL Busbar having various diffrent size in A , B & C Type pannels against damaged busbars and making the connection existing cable. (All material shall be provided by the contractor) |
| 35 | AL Busbar having size 10x35x800 mm (A/B Type Pannel Busbar) |
| 36 | AL Busbar having size 10x25x600 mm (A/B Type Pannel Busbar) |
| 37 | AL Busbar having size 6x25x300 mm (C Type Pannel Busbar) |
| 38 | Replacement of Lugs |
| 39 | Replacement of damaged Aluminium Lugs from the cable with the help of crimping tool of sizes 630, 400 sq mm. |
| 40 | Replacement of damaged Aluminium Lugs from the cable with the help of crimping tool of size 240 sq mm. |
| 41 | Replacement of damaged Lugs from the cable with the help of crimping tool of sizes 120, 70, 50, 35sq mm. |
| 42 | Replacement of damaged Lugs from the cable with the help of crimping tool of sizes 16, 10 and 6 sq mm. |
| 43 | Replacement of Alluminium Connectors |
| 44 | Replacement of damaged Alluminium connectors size 50 and 100 sq mm. |
| 45 | Replacement of damaged Alluminium leads size1x35 sq mm for connecting MCCB to cable Via connectors. |
| 46 | Note:-All Item Rate filling with GST by the firm Please Enable Macros to View BoQ information |