| 1 | INTERCEPTOR SEWER |
| 2 | Excavation below G.L. upto depth as specified for laying sewer and manhole ordinary soil (earth, sand, loam and clay) including cutting of joints pits ramming dressing) leveling, refilling of trenches in 20 cm layer watering and ramming the same including (8% reduction due to excavation already taken in .manhole and SCC) |
| 3 | (a) 0.00 to 1.50 m |
| 4 | (b) 01.50 to 03.00 m |
| 5 | (c) 03.00 to 04.50 m |
| 6 | (d) 04.50 to 06.00 m |
| 7 | Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete |
| 8 | (a) 1.5 to 3 m |
| 9 | (b) 03.00 to 06.00 m |
| 10 | Same as item No. 3 but for open timbering (No timbering for depth <1.50m) |
| 11 | (a) 1.50 to 03.00 m |
| 12 | Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s).NP3 |
| 13 | 350 mm dia |
| 14 | 400 mm dia pipe |
| 15 | 500 mm dia pipe |
| 16 | 800 mm dia pipe |
| 17 | Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment350 mm dia pipe |
| 18 | 00.00- 0 1.50 m |
| 19 | 400 mm dia pipe |
| 20 | 01.50 - 0 3.00 m |
| 21 | 500 mm dia pipe |
| 22 | 04.50 - 06.00 m |
| 23 | 800 mm dia pipe |
| 24 | 04.50 - 06.00 m |
| 25 | Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. |
| 26 | (a) 00.00 to 01.50 m |
| 27 | (b) 01.50 to 03.00 m |
| 28 | (d) 04.50 to 06.00 m |
| 29 | Construction of circular type brick masonry HD (HD20) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete as per specifications. |
| 30 | 900mm internal dia., 1.65m deep |
| 31 | 1200mm internal dia., 3.30m deep |
| 32 | 1500mm internal dia., 4.95m deep |
| 33 | Extra for every additional depth of 1 m or part there of in following size of circular manholes. |
| 34 | 900mm internal dia., 1.65m deep |
| 35 | 1200mm internal dia., 3.30m deep |
| 36 | 1500mm internal dia., 4.95m deep |
| 37 | Dismantling/Cutting of Concrete road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. |
| 38 | Bituminous road |
| 39 | Concrete road |
| 40 | Interlocking tile road |
| 41 | B.O.E road |
| 42 | Reinstatement of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. |
| 43 | Bituminous road |
| 44 | Concrete road |
| 45 | Interlocking tile road |
| 46 | B.O.E road |
| 47 | Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. |
| 48 | Disposal of Surplus Earth |
| 49 | Tack & SDBC Coat on existing BT Road (remaining area after reinstatement) |
| 50 | Co-Treatment Facilities (STP (3.9 MLD) cum FSTP (5 KLD) |
| 51 | Design, Construction, Supply of all materials, Erection and Commissioning of co treatment facilities (3.9 MLD STP cum 5 KLD FSTP) with all the civil, electrical , mechanical, instrumentation and scada system, LT/HT panel, sub station building, DG set foundation, admin buidling, laboratories, meter room and campus development [Construction of Internal Road (CC Road, 3.5m wide, area approx 1500sqm.), staff quarters as per requirement and specification, external water supply (20KL tank including tube well and pumping arrangement, electrification & street llighting and sanitation work),outfall arrangement till outfall point etc. all complete for STP with co-treatment facilities. STP shall be based on SBR Technology. The effluent quality for agricultural uses (PH-6.5 TO 8.3, SS-30 mg/l, Oil&Grease-10 mg/l, BOD-10mg/l) , COD-30 mg/l , Residual chlorine-nil , TKN-10mg/l, Nitrate N-10 mg/l, F.C.-230 MPN/100 ml, Dissolved P-5 mg/l (preferable 2 mg/l). ) shall be maintained as per CPHEEO manuals. Latest NGT norms for effluent discharge shall be adhered. |
| 52 | Civil works |
| 53 | Construction of Boundary Wall 1.8m ht. above plinth level with RCC Column @3m c/c with plinth beam and foundation avg. 1.2m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site |
| 54 | MS gate (3.6m wide with wicket gate) |
| 55 | SEWAGE PUMPING STATION - MPS |
| 56 | Cnstruction of IPS as per specification, accesory building & design approved by Engineer in Charge |
| 57 | Civil works |
| 58 | Sewage Rising main from MPS |
| 59 | Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m. |
| 60 | 0.0 to 1.5 mtr. Depth (do - in all kindes of soil) |
| 61 | Supply of 350mm dia. DI K7 pipe and special for the pumping mains including all complete pipes conforming to IS : 8329 - 350 mm |
| 62 | Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.(350mm) |
| 63 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete 150 mm |
| 64 | Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, with cast insitu RCC slab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10 shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawingSluice valve, Air valve chambers |
| 65 | Carting of 350mm dia DI K7 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. |
| 66 | Dismantling/cutting of BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. |
| 67 | Reinstatement of BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. |
| 68 | Interception and diversion (I&D) Structure works |
| 69 | Construction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge including strengthening,repairing of drain as per requirement for tapping. (Drain-1) |
| 70 | Construction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge including strengthening,repairing of drain as per requirement for tapping. (Drain-2) |
| 71 | Electrical & Mechanical works at STP |
| 72 | Electrical & Mechanical works at MPSThe complete turnkey-based execution of an SBR-based STP of 3.90 MLD capacity with co-treatment of 5 KLD shall include manual fine screen, mechanical fine step screen, vortex grit removal system, diffusers, decanter mechanism, RAS and WAS pumps, blowers, mixers, aeration system, piping and valves including actuator-operated sluice valves, online DO and MLSS sensors, OCEMS, PLC–SCADA system with HMI, screw press/sludge dewatering machine with sludge feed pump, chemical treatment and dosing system, complete HT/LT electrical system with outdoor sub-station comprising transformers (1 Working + 1 Standby), HT/LT panels, cabling and earthing, DG set with AMF panel, complete campus lighting system, DG set and transformer foundations, fencing of the sub-station as per Indian Electricity Rules (IER) and statutory requirements, and all other associated, incidental and ancillary works required for proper and complete execution of the project.The scope shall cover design, engineering, supply, installation, testing, commissioning, trial run, training and documentation, and the work shall be treated as complete in all respects under a turnkey project. The coarse multi-rack mechanical bar screen of 20 mm spacing for MPS is also included in the STP cost.The STP shall be fully automatic and operated through SCADA; hence, all equipment shall be SCADA-compatible and integrated. A Main Control Station (MCS) shall be provided at the STP as per UPJN norms, including a 65\\" LED smart monitor, desktop computer with 32\\" monitor, required furniture, and air-conditioning system.No extra claim shall be admissible for any item required for the successful completion and operation of the STP. The item-wise BOQ breakup, covering all equipment, systems and associated works, shall be submitted by the contractor and shall be scrutinized, finalized and approved by the Department.Obtaining Consent to Establish (CTE), Consent to Operate (CTO), and all statutory approvals/NOCs, including those from the Electrical Safety Department and other authorities related to electrical works, shall be entirely within the contractor’s scope and at the contractor’s own cost.Supply of Multirake type Stainless steel (SS-316), Mechanical Course Bar Screm-20 gaping), Ultrasonic type differmial level sensor, control paned for course har screams, belt coveyor etc. complete in all respect suitbale to handle peak flow - 1 Job |
| 73 | Supply of sewage submersible non-clog pumps, vertical spindle type pump Pump shall be capable of handling min 125 mm solid size with sewage specific gravity of up to 1.05. Pump shall be of robust construction,. Pump Impeller should be of Non-clog semi open type , single vane / multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should be provided. Pump should be provided with automatic coupling device including pedestal, stainless steel guide pipe or related accessories of suitable size to facilitate lifting and lowering into guide rails for easy maintenance. Pump speed shall be of 1450 rpm. The submersible motor shall be operated with 3ph, 415 V(+/– 10%), 50Hz(+/-5 %) .The rotating assembly shall be dynamically balanced as per standards. Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS 4691. Motor shall be suitable for continuous operation in fully submerged or partially submerged condition. MOC:Pump casing/Housing - CI Gr. FG 260 :IS210 with 2% NICI, Impeller - CF8M, Shaft - Stainless steel AISI 410, Guide Pipe - SS 316, Lifting Chain - SS 304Pumping plant of following rating capacities. (Note: The discharge and head indicated are tentative and shall be finalized during execution of the work.) |
| 74 | CAPACITY:- 3500 LPM/ 32 Mtr. HEAD/ 50 HP (2w+1s) |
| 75 | CAPACITY:- 1400 LPM/ 32 Mtr. HEAD/ 10 HP (1w+1s) |
| 76 | Supply of (SS-304 Metal seated) DIDF Sluive valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated sluice valve suitable to SCADA operation Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes suitable for sewage applications of following sizes at pump delivery |
| 77 | 150 mm Dia size |
| 78 | 200 mm Dia size |
| 79 | 300 mm Dia size at common header |
| 80 | Supply of DIDF Single Door/ Multi Door Non return/reflux valve conforming to relevent IS, PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing suitable for sewage applications of following sizes |
| 81 | 150 mm Dia size |
| 82 | 200 mm Dia size |
| 83 | PipingsNote: Regarding the size of pipes. Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing |
| 84 | 150 nm, K9 delivery pipes for small pumping plants |
| 85 | 200 num, K9 delivery pipes for large pumping plants |
| 86 | 300 mm, K9 common header pipes |
| 87 | Specials like bend, tee, D Joint etc |
| 88 | GI Nut Bolt, Washer Rubber packing etc |
| 89 | Supply of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump (for Hi-Lo cut-off & alarms). The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display |
| 90 | Supply of CE/UL certified Electro magnetic flow meter suitable to measure 0 to 30 MLD flow to be fitted in 300 mm dia main header line |
| 91 | Supply of 3 Tonn EOT crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lin complete with wire rope hoist, class II duty, all three motions electrically operated by suitable raung moter IP 54, control panel and dowu pendent control block with gurder etc. required for proper completion of the work. |
| 92 | Painting of all pumps piping and valves with two coat epoxy paint |
| 93 | SCREENS AND GATES:Supply of Rising type thinsble mounted CI Sluice Gates of reputed make at MPS |
| 94 | Supply of Stainless steel Mannal Servon (20 mm gaping) suitable to handle peak flow. |
| 95 | TransformerSupply, installation, testing & comissioning of outdoor type level-1 Copper wound distribution Transformer of 160 KVA rating 11/0.433KV with off-LTC (+5% to - 10% @ 2.5%) Delta-Star Connected, Vector Ciroup Dyn 11.ONAN Cooled & losars as defined as per 15 1180 part 2014 including standard accessories like conservator, silica gel breather, radiator, fins, OTI, WTI, Buchholz relay, HT cable box & LT cable boxes, temperature rise in windmg/oil 35-40 degree C151 marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per 15 335-1953. Ероxy based pamt including carrying of pre-commision Testing & Charging of Transformer compiere in all respect |
| 96 | HT.Panel Comprising of 1No. -I/C and 2No. -O/GSupply, Installation, Testing and Comissioning of incomming panel 11 KV, 630 A, 20kA/3 sec, Out door Extmaible type IP54 for ATP67 for main circuits Ring main unit OLMU) IEC 62271-200 in suitable RCC foundation with 2 no Loed break switch & 1 ne VCB circuit breaker with over load, Earth fault, short circuit mlay, copper bus bar, bus support and insulation starrial epoxy resin,ring core protection & metering CT, Auxiliary relay for WTI, OTL Bucholz alarm & trip along with annuciator panel, master trip relay, mechanical ON/OFF/Earth indication, Voltage presence indicator, Shunt trip coil, 24 V DC power pack, VT ratio of suitable capacity, Digital milti function meter, with Bus PT paned with 3 Nos singic pliase voltage transformers of the rabo 1kV/43/110 V/N3, 25 VA Class 10 with HT Fuses in the primary and MCB the secondary side Voltmeter with selector switch, RYD phase indication, Anti reflex operating handle, right angle boots etc. Every VCB Panel should have I power pack with battery charger and charging devsoc complete in all respect |
| 97 | Supply, Installation, Testing and Comissioning of outgoing panel 2mm thick factory made 11 KV, 630 A, 20kA/3 sec, Out door Extmsible type IP54 for panel & IP67 for main circuits Ring main unit (RMU) IEC 62271-200 in suitable RCC foundation with 2 no Load break switch & 1 no. VCB crcuit breaker with over load, Earth litult, short circuit relay, copper bus bar, bus support and insulation marasal epoxy resinting cure protection & nattering CT, Auxilimy relay for WTI, OTI, Bucholz alarm & trip along with annuciator panel, master trip relay, mechanical ON/OFF/Earth indication, Voltage presence indicator, Stunt trip coil, 24 V DC power pack, Digital multi function meter, with Bus PT panel with 3 Nos single phase voltage transformers of the ratio IkV/3/110 VN3, 25 VA, Class 10 with HT fuses in the primary and MCB on the secondary side, Voltmeter with selector switch, RYB phase indication, Anti reflex operating handle, right angle boots etc. Every VCB Pand should have I power pack with battery charger and charging device complete in all respect-RefE23.73 (PRE BSR 2022) |
| 98 | Providing & Laying XLPE insulated as per IS 7098/11/85 HT cable as per PWD specification for electrical Works for working voltage II KV (E) in existing RCC/Hume Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc |
| 99 | 3 core X 120sq mmm armored IT Cable (From HT Panel to Transformers) |
| 100 | SITC of 11 KV End Termination Kit 3 care, 120 sqmm) |
| 101 | 11 KV, 2.5 mm thick with proof voltage 22 KV/3 min. and Berak Down Voltage 45 KV Ref 10.2 (PRE BSR 2022) |
| 102 | L.T. panel |
| 103 | Supply, Installation, Testing and Comissioning of 0.415 LV LT control panel for pumping plant LT control panel suitable to operated on 415-6% vol. 3 Phase, 50 Hz. AC supply as per details given below AJ2 Nos incomag MCCB panels aml 1 No outgoing MCCB panel each comisting of following items (14 pole MCCB 250 A Rating 35 kA- Noi) CTs of suitable ratio No (i) Ammeter with selector switch- No (iv) Voltmeter wwh selector swinch- 1 No (1 Power factor meterto 5 Lag&O SLead) Nn (vi) Frequency meter-1 No rv) KWII meter I No (2. Pole over current iclay & une pole earth fault retas No (B)Bus har chamber having 3 Nos bus bars for phase and 1 No bus har for neutral of suitable sinz-1 Nu (C)3 Nos compatic panels for pumping plants, cach consisting of following tems-1114 pole MCCB 160 A current ning 23 KA short circuit breaking capacity With Microprocessor huned release with adjustable adjustable O/L & S/C setting with Inbuilt instantaneous and Ground Fauli Protection - Not Ts of suitable ratio- I No (ii) Ammeter with selector swach - Ne (iv) Automatic start/stop device acconding to level in the sump | Notvindicating lamps(Auto/manual/low level/ reverse rotation)- Set (D) 2 Nos. composine panels for pumping plants, each consisting of following items (1) 4 pole MCCB 63 A current rating 25 KA short circuit breaking capacity With Microprocessor based release with adjustable adjustable OL & S/C setting with Inbuilt Instantaneous and Ground fault Protection-1 No.(11) Ts. of suitable ratno-1 No (Ammeter with selector switch-1 No (iv) Automatic start/stop device according to level in the sump- 1 No (v)Indicating lamps(Auto/manual/low level reverse mtation) - 1 Ser (F) 1 Nos outguing pancis for miscellaneous works, cach consisting of following rams(1) MCB of 40 A capacity- No (1) CTs of suitable ratio- No (ur) Ammeter with selector switch-1 No (iv) ledicating lamps- 1 Set (F)APFC Panel for total load (G) 4 pole 400 A Rating 35 kA Panel for DG sets incoming-INO (G) Bus coupler arrangement in panels |
| 104 | Supply and Laying and jointing of LT Power and control cable-Supply of Armored 120 sq mm 15 core cable-2 Run required for power from each Transformer to each: LI panel, Unannored 130 sq mm X3 core-1 run cable for power Imm starters to 50 HP Motors & Unansored 10 mm X core- run cable Sar power from starters to 10 HP Moturs including hugong and jointing, laving bench excavation and compaction as well as compless cabling of autcmation system etc. complete in all respect. |
| 105 | Supply, Installation, Testing and Comissioning of Plate Earthing as per IS 3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 30mm by embodying 3 mtr below the ground level with 20 mm dia. G.I. 'B' class watering Pipe, including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm. Buttom Dia 300 to 350 nm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. |
| 106 | Supply, Installation, Testing and Comissioning of Pipe Earthing as per IS:3043-1987 with 3.0 Mtr. Long, 40 mm dia. 'B' class G1 Pipe IS: 1239 (Part-1) 2004, Equivalent to BS: 1387 with perforated holes of 12 mun dia including all accessories like nut, bolts. seducer, nipple, wire meshed funnel, and Heavy duty weather proof poly propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of suze Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of carth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book All as per pre approved by Engineer in charge |
| 107 | Supply & Laying of 50mmX6mm size Gf earth strip in horizontal or vertical run in ground/surface'recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Gl nut bolt & spring washer 140 spaced at 50cm making consection etc (20meter for each earthing) |
| 108 | Expendititure on B&L Form, Challan, NOC from electrical safety department etc. |
| 109 | Proper fencing of substation as per I.R. rules, |
| 110 | Supply, Installation, Testing and Comissioning of 3mm thick M.S. chequerred plate over all the run of cables trenches to cover properly and MS grill and M.S guard over all pipes ducts and other point where required as per site condition. |
| 111 | STARTER PANEL |
| 112 | Supply, Installation, Testing and Comissioning of Variable Frequency Drive, suitable to meet the basic requirement of motor protections and suitable to run 50 HP motor (To be fixed in composite panel of LT Panel) |
| 113 | Supply, Installation, Testing and Comissioning of Variable Frequency Drive, suitable to meet the basic requirement of motor protections and suitable to run 10 HP motor (To be fixed in composite panel of LT Panel) |
| 114 | D.G. SET AND ACCESSORIES |
| 115 | Supply, Installation, Testing and Comissioning of Radiator Cooled and Turbo charged Silent type DG set, engine alternator capable of developing 160 KVA at 415-6%, 50 Hz AC at 0.85 P.F lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start, Batteries with battry charger, Engine instruments panel, AVM 19 pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, IUPM, Low Lube Oil tripping & control system, Ammeter, Voluneter, PF meter, frequency meter, KWH meter, digital faed display metr, Ind. lamps etc. mounted inside enclosure, visible and accessiblefrom outside. T 3 Met exhaust pipe, D.G. set shall be mounted undr open sky resting on the foundation as per design. |
| 116 | Supply, Installation, Testing and Comissioning of PLC Based Auto main lailure (AMF) Panel for 160 KVA DG Set fabricated from CRCA short steel 2 mm Thick, Powder cuated finish, Engine Start & Stop commands, control Relays, Amunster & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter, Visaal & Alarm indication for faults, operator interface panel complete in all respect |
| 117 | Supply, Installation, Testing and Comissioning of Pipe Earthing as per IS:3043-1987 with 3.0 Mtr. Long, 40 mm dia. 'B' class G.1. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS 1387 withperforated holes of 12 mm dia including all accessories like nut, bolts, reducer, nipple, wire mshed finnel, and Heavy duty weather proof poly propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or Dia 300 to 350 nun. and Height 250 m 300 mm. and embodying the pipe complete with alternate layers salt and coks/charcoal, testing of earth resistance for value of 5 ohms or less as required |
| 118 | Supply, Installation, Testing and Comissioning of Plate Earthing as per IS 3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0min by embodying 3 mir below the ground level with 20 mm dia. G.1. 'B' class watering Pipe, including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly propylene carth pit chamber with lockable Jam free lid suitable for salie working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Buttom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of carth resistance for value of 5 ohms or less as required. |
| 119 | Supply & Laying 50 mm X 6mm size Gf earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulatur including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brasa (for Cu strip)/Gl (fur Gl Strip) nut bolt & spring washer spaced at 50cm making connection esc as required |
| 120 | Providing and Layung cable for DG Set to Panel 120 sq mun X 35 core x 2 run armored aluminium |
| 121 | Supplying and making one end urmination with harvy doty beam unimpension gland (s per 15 12943-1990) 51110 туpe, heavy duty alumumum hugs (as per 15 8300-1993 & 15 6337-1976) daly crumped with crimping tool, PVC tape 25 as per PWD specification for electrical Works ett for fallewing size of Armoured PVC insulated & PVC sheshed/ XLPE alumnium conductor table of 1100 volt grade for 3.5 com X 240 sqmm |
| 122 | LIGHT WIRING & Electrification |
| 123 | Complete Electrification of LT Panel room with 2 Not Faust Fan |
| 124 | Complete Electrification of HT Panel room with 2 Not Faust Fan |
| 125 | MPS Campus with Solar Panel and LED Light of 3 sets |
| 126 | core i7 processor Desktop with 32\\" monitor and licence MS office/laptop 12 GB-1TB SSD for the office |
| 127 | Laser printer colour with both side printing facility and wifi with top load scanner etc. |
| 128 | Installation, testing, and commissioning of all pump sets, piping, and valves, substation, DG set etc. and all above associated equipments etc. including chequered plates, as per the approved drawings submitted by the contractor and duly approved by the department. |
| 129 | AUTOMATION OF MPS |
| 130 | Supply of CE & UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places |
| 131 | Supply of GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data frorn remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification |
| 132 | Supply of CE/UL certified intellignet Smart Energy Meter |
| 133 | Supply of Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-& IEC-60947-b-1) of 160 amp. |
| 134 | Supply of Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The meterial of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator |
| 135 | Supply of CE/UL Certified Surge protechor for commin panel |
| 136 | Supply of CE/UL Certified 7\\" HMI touch screen suitable to communication with PLC/RTU . |
| 137 | Security Survsliance IP Camera with recorder. |
| 138 | Installation, Commissioning & Testing of above automation work. |
| 139 | Trail & run for 03 months diesel consumption & lubricants for STP |
| 140 | Trail & run for 03 months diesel consumption & lubricants for MPS Please Enable Macros to View BoQ information |