| 1 | Surface excavation n.exc. 30 cm in deep and averaging 15cm deep and getting out soft/loose soil. complete all as specified and as directed. |
| 2 | M&L for hardcore of broken stone or boulders of gauge exc. 63mm but n.exc. 100mm, deposited, spread levelled in layers n.exc. 15cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed. |
| 3 | M&L for 75mm thick Plain Cement Concrete, (1:3:6) type C2 (using 40mm graded stone aggregate) as in flooring and finishing cement concrete surface even and smooth, copping even and fair without using extra cement complete all as specified and as directed. |
| 4 | M&L for 50mm thick Plain Cement Concrete (1:3:6) type C1 (using 20mm graded stone aggregate) as in plinth protection complete all as specified and as directed. |
| 5 | M&L for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and as directed. |
| 6 | S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size (915mm x 460mm) bowl size (410mm x 330mm x 160mm) complete all as specified and as directed. |
| 7 | S&F for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 8 | S&F for PVC (SWR) bends of 110mm bore laid in trenches complete all as specified and as directed. |
| 9 | S&F for PVC (SWR) reducers 110mm bore laid in trenches complete all as specified and as directed. |
| 10 | M&L for 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cmenet and other end fixed complete all as specified and as directed. |
| 11 | M&L for 75mm dia of outlet PVC floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 12 | M&L for 15mm bore steel water tubing medium grade galvanised with and including all fittings and fixed, to walls and ceilings or laid under floors including taking down complete all as specified and as directed. |
| 13 | S&F of 15mm bore pillar taps, cast copper alloy, with capstan heads chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 14 | M&L for Pre Cast Cement Concrete solid block masonry 10 cm thick in PCC (1:3:6) type C-1 (using 20mm graded aggregate) set in CM (1:4) complete all as specified and as directed. |
| 15 | M&L for preparation of new surfaces and applying three coat of Colour wash on wall surfaces complete all as specified and as directed. |
| 16 | M&L for painting to steel surfaces of any description, over to 10 cm width or girth, not other wise described, painting two coats of synthetic enamel paint over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and as directed. |
| 17 | M&L for MS angle or tee sections fixed independently, without connecting plates of Fe-410W (Gde E-250). complete all as specified and as directed. |
| 18 | S&F for 4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position including closing after filling complete all as specified and as directed. |
| 19 | Removing excavated material/soil for n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point. complete all as specified and as directed. |
| 20 | Excavation in any type of soil by mechanicl means (Hydraulic excavator) over areas (exceeding 30cm in depth, 1.50m in width as well as 10 square metre on plan) but n.exc. 1.5m depth, including getting out and disposal of excavated earth lead upto 50m and lift upto 1.50m complete all as specified and as directed. |
| 21 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation bed to drains complete all as specified and as directed. |
| 22 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in walls to drains complete all as specified and as directed. |
| 23 | Use and Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed. |
| 24 | Use and Waste of formwork to faces of walls,retaining walls,abutments.parapets and similar works including attached pillasters, buttresses etc. vertical or to batter for rough finished surfaces of concrete using steel complete all as specified and as directed. |
| 25 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed. |
| 26 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm for soft/loose soil complete all as specified and as directed. |
| 27 | Removing excavated material/soil n.exc. 50m and upto a total distance of 250m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and as directed. |
| 28 | Excavation over area n.exc. 1.5m deep and getting out for soft / loose soil complete all as specified and as directed. |
| 29 | Excavation in trenches n.exc. 1.5m wide and n.exc. 1.5m in depth; for foundation, etc. or for shafts,wells,cesspits, manholes, pier holes, etc. n.exc. 10 sqm on plan and n.exc. 1.5m depth and getting out for soft / loose soil. complete all as specified and as directed. |
| 30 | M&L for 200mm thick GSB of kankar or laterite spread,rolled and consolidated to gradient and camber required complete all as specified and as directed. |
| 31 | M&L for PCC (1:3:6) type C-2 (using 40mm graded aggregate) as in packing between the culverts complete all as specified and as directed. |
| 32 | Supply and Laying of 600mm dia Reinforced Concrete pipes , class NP2 laid and jointed complete with collars complete all as specified and as directed. |
| 33 | M&L for moorum / red bajri filling in floors or pavings, laid in layers n.exc. 15cm thick , spread, levelled and rammed including watering complete all as specified and as directed. |
| 34 | M&L for machine pressed coloured cement concrete chequered tile of size 300 x 300 x 20mm thick set and jointed with neat cement slurry in floors over 20mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 35 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4), smooth finished complete all as specified and as directed. |
| 36 | M&L for Boulder pitching of 300mm thick hand packed tightly complete all as specified and as directed. |
| 37 | M&L for 75mm PVC (SWR) pipes as in weep holes. complete all as specified and as directed. |
| 38 | M&L for Hardcore (broken stone or boulders) of gauge n.exc. 0.63mm deposited, spread and levelled in layers n.exc. 15cm thick watered and rammed to a true surface. complete all as specified and as directed. |
| 39 | S&F for framed work as in balusters hand rails parapets including cleats, brackets etc of grade Fe 410-W (Gde 250) complete all as specified and as directed. Please Enable Macros to View BoQ information |