| 1 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4.0core complete all as specified and directed. |
| 2 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5core complete all as specified and directed. |
| 3 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5core complete all as specified and directed. |
| 4 | Excavation in trenches n.exc 1.50 mtr wide and n.exc 1.50 mtr deep for taking out/ laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed. |
| 5 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread any type of soil complete all as specified and directed. |
| 6 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed. |
| 7 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed.Note: Punned thickness of sand shall be measured & paid. |
| 8 | M&L for well burnt sub class 'B' bricks of nominal size 230x115x75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick including taking out old complete all as specified and directed. |
| 9 | Supply, install, testing and commissioning of LT outdoor Feeder Pillar Box AC 415 V, 50 Hz 3 Phase 4 wire, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 54, double door type with bottom cable entry with suitable cable glands structure made out of 3.15 mm (outer) & 2.00 mm (inner) thick CRCA steel sheet of minimum size (1.0x0.8 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- (Locaton- Post-4,,Post-10,)INCOMER :-(a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 100 Amps with fixed thermal and fixed magnetic setting- 01 NoBUSBAR :-(i) Aluminium bus bar 200 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 NosINDICATING DEVICES :-(a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos.(b) Supply and fixing Digital Ampere Meter of 0-200 A, 3 phase, class 1 with selector switch including CT having CTR 105/5 - 01 No(c) Supply & fixing Digital Voltmeter 0-500 Volts, 3 phase, class 1 with selector switch- 01 NoOUT GOING :-(a) Supply and fixing MCCB 3P, 40Amps, 220 Volts, C curve of breaking capacity of 10KA - 3 Nos (b) Supply and fixing Astronomical digital Timer switch along with contactor 3P 16Amps, 415V, 50Hz for street light controlling. |
| 10 | S&F in replacement of floor mounted LT OUTDOOR feeder pillar box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick with CPRI Approved CRCA steel sheet of Size ( 0.8 x 0.8 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated, complete all as specified and directed . BUSBAR :-(a) Aluminium bus bar 400 Amps with 04 No nutbolts&washer on each busbar at eqaul interval , supported on non hygroscopic fibres and brass screws for mounting -04 NosINCOMER: -(a) Supply and fixing main incommer Changeover of OF 4 Pole,415 Volts of capacity 250 Amps with thermal magnetic release-01 Nos(b) Supply and fixing Main Incoming MCCB OF 4 Pole,415 Volts of capacity 250 Amps with thermal magnetic release-01 NosINDICATING DEVICES: -(a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos(b ) Supply and fixing Digital Ampere Meter of size 100mmX100mm for 0-300 A display, incl CT having CTR 250/5 - 01 Nos & Digital Voltmeter 0-500 Volts, SIF 96 - 01 Nos |
| 11 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 50 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 12 | M&L for PCC cable route indiacator made out with 300 x 300 x 300 mm thick PCC Block of 1:3:6 type C1 by using 20mm gradded aggragate and embossing HT indicator made out with MS / CI round shaped sheet welded with 200 mm long MS flat iron including 2 coats of synthetic enamel paint over one coat of red oxide primer to iron surfaces fixing at different cable routes complete all as specified and directed. |
| 13 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6.3mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 14 | Taking down old U/S cable of various size from trenches of any depth and deposite to MES E/M store yard for further disposal as schedule of credit to the contractor complete all as specified and directed. |
| 15 | M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing water pipe line upto 110mm complete all as specified and directed. |
| 16 | Taking down old GI/MS/PPR pipe with fitting of 25/32 mm bore from surface/ trench including dismantling and removing (except serviceable pipe for re-fixing) materials from work site complete all as specified and directed.Note:- Earthwork shall be measured & paid separetely. |
| 17 | All as per item No. 16.00 above but pipe of 63 mm bore complete all as specified and directed. |
| 18 | All as per item No. 16.00 above but pipe of 90 mm bore complete all as specified and directed. |
| 19 | Supply, laying, jointing and testing 3 layer PPR Polypropylene random copolymer concealed pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PPR plain and brass threaded polypropylene random fittings laid in trenches / wall/ surface including all fittings & necessary clamps of outer dia 25 mm, SDR 7.4 (PN-16) complete all as specified and directed. Note:- Earthwork shall be measured & paid separetely. |
| 20 | All as per item No. 19.00 above but pipe of 32 mm, SDR 7.4 (PN-16) complete all as specified and directed. |
| 21 | All as per item No. 19.00 above but pipe of 63 mm, SDR 11 (PN-10) complete all as specified and directed. |
| 22 | All as per item No. 19.00 above but pipe of 90 mm, SDR 11 (PN-10) complete all as specified and directed. |
| 23 | S&F for PPR Gate Valves (Brass insert) of 25 mm outer dia including taking out old unservicble valve complete all as specified and directed. |
| 24 | S&F for PPR Gate Valves (Brass insert) of 32 mm outer dia including taking out old unservicble valve complete all as specified and directed. |
| 25 | S&F for PPR Gate Valves (Brass insert) of 63 mm outer dia including taking out old unservicble valve complete all as specified and directed. |
| 26 | S&F for PPR Gate Valves (Brass insert) of 90 mm outer dia including taking out old unservicble valve complete all as specified and directed. |
| 27 | S&F in replacement of cast iron sluice valve of 80 mm bore, class PN 1.6, ISI marked with iron wheel head both end flanged, brass spindle any pattern with check nut complete with jointing material nut, bolt and washers etc complete all as specified and directed. |
| 28 | S&F in replacement of of 100 mm dia CI butterfly vale gear operated wafer type, ISI marked complete with jointing material nut, bolt and washers etc complete all as specified and directed. |
| 29 | M&L for construction of valve pit chamber of internal dimension 40 x 40 x 40 cm with sub class 'B' bricks in cement mortar (1:4) and 10 mm thick plastering in cement mortar (1:4), PCC (1:4:8), type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6), type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 5 mm angle iron and 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, two coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/ loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete including dismantling of old complete all as specified and directed. |
| 30 | M&L for construction of valve pit chamber of internal dimension 90 x 90 x 90 cm with sub class 'B' bricks in cement mortar (1:4) and 10 mm thick plastering in cement mortar (1:4), PCC (1:4:8), type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 5 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/ loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete including dismantling of old all as specified and and directed. |
| 31 | Demolition of cement concrete unreinforced, in ground floor or pavings below or above ground level from foundation of filtration plant including removal of debris from site complete all as specified and directed. |
| 32 | M&L for PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregates as in foundation, sub base or mass concrete complete all as specified and directed. Material and labour laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. Please Enable Macros to View BoQ information |