| 1 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). .E&M DSR 2025 32.2 |
| 2 | Inverter Type – Cooling only . |
| 3 | 1.5 TR with 5 Star BEE Rating .32.2.3 |
| 4 | Minimum Cooling Capacity rating: 5000 watts & above. . |
| 5 | Make: Carrier /Hitachi /Mitshubishi /Daikin /Voltas /Bluestar or any other make as per approved make list. . |
| 6 | Providing and fixing of voltage stabilizer suitable for 1.5 TR air conditioner capacity 15 Amp. Working range 150 VAC - 285 VAC with low and high voltage cut off protection built in thermal overload protection, digital/analog display for input/output voltage with wall mounting metal cabinet, complete of make V-Guard model VND 500 or equivalent model of Deol, Microtech, Luminous or any other make as per approved make list. .NSR |
| 7 | 4 KVA capacity . |
| 8 | Providing & Fixing of Powder coated ready made heavy duty out door stand for Split out door as per site requirement to the entire satisfaction of Engineer- in Charge. .NSR |
| 9 | Providing and Fixing of PVC Rigid drain Pipe complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials Diplast or any other make as per approved make list. .NSR |
| 10 | Providing and Fixing of 22 gauge soft copper piping of size 3/8\\" / 5/8\\" or as per original manufacturer technical specification for A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing to original condition. The rate per meter includes cost of 1 meter No's of both 3/8” & 5/8” with insulation. Make Rajco tubes, Mandev, Maxflow, Totaline or any other make as per approved make list. .NSR |
| 11 | Providing & fixing of 3 core 2.5 sqmm flexible copper wire as per specifications complete as per site Makes Havell, Polycabs or Finolex or any other make as per approved make list. .NSR |
| 12 | Providing and fixing of PVC Trunking Channel to cover the exposed copper pipe cable and drain pipe. .NSR |
| 13 | PVC Trunking 50x100mm (White Color) . |
| 14 | Cutting holes up to 30x30 cm in walls including making good the same: .18.76 |
| 15 | With common burnt clay F.P.S. (non modular) bricks .18.76.1 Please Enable Macros to View BoQ information |