| 1 | Boring of 30cm dia piles of single under reamed of 50cm dia of bulb and 3.5 meter depth in black cotton soil with hand operated auger machine including all laboure T&P etc. for proper completion of work as per IS code-2911(Part-III) 1980. |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:(All kinds of soil)As per DSR-2.1.1 |
| 3 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.As per DSR-2.27 |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).As per DSR-4.1.8 |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) :.As per DSR-5.2.2 |
| 6 | Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth Cement morter 1:4 .As DSR NO.- 6.1.1 |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars.As per DSR-5.22.1 |
| 8 | CEMENT PLASTER (IN FINE SAND)12 mm cement plaster of mix :in 1:4 (1 cement: 4 fine sand).AS per DSR No.- 13.1.1 |
| 9 | 4 cm thick cement concrete floor 1:2:4 finished with a floating coat of neat cement including cement slurry,but excluding cost of nosing of steps etc all complete.As per DSR no.- 11.3.1 |
| 10 | Providng and laying of 8 to 10mm thick ivory or light shade vitrified tiles of 600mm x 600mm size in flooring or skirting laid with 1 : 3 cement mortar (1 cement , 3 coarse sand) finishing with cement sturry & with pigment grouting & Polishing complete I/C S/O all material labour T & P etc. required for proper completion of work excluding base contrete. |
| 11 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.As per DSR No.- 13.88 |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 14 | supply & Fixing of 10cm Internal dia PVC pipes complete with rose- heads, bends abd gratings & including supply of necessary M.S. clamps 2.5cmx3mm (1\\"x1/8\\") fixed to walls, with & including supply of 15cm (6\\") long 6mm (1?4\\") dia nails & including supply of all materials, labour and T&P etc required for proper completion of the work and also including repair of plaster, pointing etc if damaged during fixing of pipes, details of 30' length. |
| 15 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.As per DSR No.- 10.1 |
| 16 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).As per DSR No.- 10.28 |
| 17 | Painting or varnishing new iron work in small areas of new wood of 1 sqm area with one coat of ready mixed priming paint and two coat or approved superior quality ready mixed paint or varnish including supply of all material, labour and T&P etc. required .AS per SOR |
| 18 | Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).Red sand stone - 30mm thick gang saw cut stone.Asper DSR No.-8.20.1 Please Enable Macros to View BoQ information |