| 1 | Contract Details |
| 2 | Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site all as specified. |
| 3 | M&L for cement plaster in CM 1:4, 15 mm thick in two coats (10+5) with using integral waterproofing compound finished even & fair without using extra cement ( Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items.). |
| 4 | M&Lfor rendering 15mm thick in cm 1:6 finished with neeru finish as specified on fair faces of brick work or concrete surfaces. |
| 5 | Supply only liquid water proofing compound (Make:- Scott No 1/Dr Fixit) |
| 6 | M&L preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer Over 3 mm thick wall care putty on wallscomplete all as specified and directed by Engineer-in-Charge. on |
| 7 | M&L Complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer Over 1 mm thick wall care putty on wallscomplete all as specified and directed by Engineer-in-Charge.. |
| 8 | M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) complete all as specified and directed by Engineer-in-Charge. |
| 9 | Preparation of old iron and steel surfaces of any description over 10cms width or girth and applying one coats of Synthetic enamel paint as direcected . |
| 10 | Taking down and refixing of rolling shutter and hood/top cover of any description and size including oiling , greasing of guide rails, bearinf , spring etc. (Note all accessories if required shall be measured seperately under respectinve items) |
| 11 | Supply and fix in repair ball bearing for rolling shutters. |
| 12 | Supply and fix in repair ms pipes heavy duty of 40mm dia as in shaft of rolling shutter. |
| 13 | Supply and fix in repair MS Spring for rolling shutter, size of spring 27.5 cm long wire spring grade No. 2 for rolling shutters inner dia not less than 65mm and MS wire 6mm dia as approved by Engg-In-Charge. |
| 14 | Supply and fix in repair plain black mild steel sheet for top cover for rolling shutters 1.25 mm thick as in hood of the rolling shutter all as specified and directed by Engr-In-Charge. |
| 15 | Taking out doors/ roller shutter of steel including stacking within 50 metres lead of area beyond 3 sq. metres as specified and directed |
| 16 | M&L for supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull/ manual operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover for hood as specified and directed. |
| 17 | Supply & fix in repair for providing and fixing ball bearing for rolling shutters as specified and directed . |
| 18 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete on steel work. |
| 19 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 20 | M&L for 1:4:8 type D2 using 40mm graded aggregate as in sub base floor, 75mm thick all as specified and directed by Engr-in-Charge. |
| 21 | M&L for 1:2:4 type B2 using 40mm graded aggregate as in sub base floor, 50mm thick all as specified and directed by Engr-in-Charge. |
| 22 | M&L For Glass dividing strips, 3 mm thick, 38mm in width inserting in position complete all as specified and directed by Engr-in-Charge. |
| 23 | Note :-Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract. Please Enable Macros to View BoQ information |