Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned upto a lead of 1000metres including removal and disposal of top organic soil not exceeding 150mm in thickness as per Clause 201 of MoRT&H Specifications for Road & Bridge works (5th Revision) & including cost of all labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. . |
| 2 | Dismantling of Granular courses of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately |
| 3 | Earth work in excavation in all kinds of soil for road works with hydraulic excavator of 0.9 Cum bucket capacity including cutting and loading in tippers as per drawing and technical specification, including setting out, dressing of section to correct line, level, grade & camber for road work or dressing of sides and bottom for foundation of structures and loading into tippers, transporting to embankment site within all lifts and lead upto 1000mtr. and utilising the surplus earth locally for road work wherever required, backfilling the excavation earth to the extent required etc complete in all respect as per clause 301 & 304 of Specification for road & bridge work of MORT&H (5th Revision) & Direction of Engineer in charge. |
| 4 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge. |
| 5 | Loosening to a depth of 150mm, leveling and compacting original ground supporting embankment /sub-grade as per approved drawing and technical specifications complete in all respect as per Section 900 and Clause 305, 305.3.4 of MoRT&H Specification for Road & Bridge works (5th Revision) & including cost of all labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 6 | Construction of embankment with approved materials deposited at site from road-way cutting and other structures with all lifts and leads graded and compacted to meet requirement as per approved drawing and technical specifications complete in all respect as per Section 900 and Clause 305 of MoRT&H Specification for Road & Bridge works (5th Revision) & including cost of all labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 7 | Construction of embankment with approved materials obtained from borrow pits by mechanical means graded and compacted to meet requirement as per approved drawing and technical specifications complete in all respect as per Section 900 and clause 305 of MoRT&H Specification for Road & Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 8 | Providing and laying Granular Sub-base with Grading-VI stone screening materials as per Table 400-1 as per approved drawing and technical specifications complete in all respect as per Section 900 and Clause 401 of MoRT&H Specifications for Road & Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 9 | Providing Wet Mix Macadam using crushed stone aggregates as per approved drawing and technical specifications complete in all respect as per Section 900 and Clause 406 of MoRT&H Specifications for Road & Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 10 | Providing and applying primer coat with slow setting bitumen emulsion on prepared surface of granular base, including clearing road surface and spraying primer using mechanical means as per approved drawing and technical specifications complete in all respect as per Section 900, Clause 501.5.2 & 502 of MoRT&H Specifications for Road & Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 11 | Providing and applying tack coat with rapid setting bitumen emulsion on the prepared bituminous/ granular surface including cleaning with mechanical broom and spraying bitumen emulsion using mechanical means as per approved drawing and technical specifications complete in all respect as per Section 900, Clause 501.5.2 & 503 of MoRT&H Specifications for Road & Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. (4th.Revision) |
| 12 | Providing Dence graded Bituminous Macadam of grading -2 using crushed stone Gr.-2 materials & 60/70 penetration grade of bitumen, preparing preemixed materials with hot mix plant, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled including cost, conveyance, royality of all materials & cost of all labour, machinery etc complete as per clauses 501 and 505 of MoRT&H Specifications for Road & Bridge works (5th Revision). |
| 13 | Providing & laying Bituminous Concrete of grading -2 using crushed stone Gr.-2 materials & 60/70 penetration grade of bitumen, preparing preemixed materials with hot mix plant, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled including cost, conveyance, royality of all materials & cost of all labour, machinery etc complete as per clauses 501, 503 and 507 of MoRT&H Specifications for Road & Bridge works (5th Revision). |
| 14 | Providing Dence graded Bituminous Macadam of grading -2 using crushed stone Gr.-2 materials & PMB (70/10) penetration grade of bitumen, preparing preemixed materials with hot mix plant, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled including cost, conveyance, royality of all materials & cost of all labour, machinery etc complete as per clauses 501 and 505 of MoRT&H Specifications for Road & Bridge works (5th Revision). |
| 15 | Providing & laying Bituminous Concrete of grading -2 using crushed stone Gr.-2 materials & PMB (70/10) penetration grade of bitumen, preparing preemixed materials with hot mix plant, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled including cost, conveyance, royality of all materials & cost of all labour, machinery etc complete as per clauses 501, 503 and 507 of MoRT&H Specifications for Road & Bridge works (5th Revision). |
| 16 | Providing dry lean cement concrete sub-base by with coarse and fine aggregates conforming to I:S 383, the size of coarse aggregate not exceeding 25mm , aggregate cement ratio not to exceed 15:1, aggregate gradation as per table 600-1, cement content not to be less than 150 Kg/Cum, mixing in concrete mixers with weigh batcher and transporting to work site, laying, spreading and compacting with PRR to the required thickness, finishing and curing as per approved drawing and specification complete in all respect as per Section 900 & Clause 601 of MoRT&H Specifications for Road and Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge |
| 17 | Providing un-reinforced, dowel jointed cement concrete pavement over a prepared sub base as per approved mix design, using 43grade cement not less than 400kg/cum, coarse and fine aggregates conforming to I:S 383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip from paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler,separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per approved drawing and technical specification complete in all respect as per Section 900 & Clause 602 of MoRT&H Specifications for Road and Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 18 | Providing road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads@250gms per sqm area , thickness of 2.5mm is exclusive of surface applied glass beads as per IRC:35.The finished surface to be level, uniform and free from streaks and holes etc. for finished item of work as per approved drawing and technical specification complete in all respect as per Section 900 and Clause 803.4 of MoRT&H specification for road and bridge work (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 19 | Providing, filling clean sand of approved quality in road work for construction of drainage layer and foundation trenches of structures in uniform layers, watered and rammed/ compacted as per approved drawing and technical specifications complete in all respect as per Section 900, 2100 and Clause 401 & 304 of MoRT&H specifications for Road & Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 20 | Providing and laying Plain cement concrete of grade M-15 in foundation bed as levelling course of CD works etc using 40mm to 10mm size crushed stone aggregates etc complete as per drawing and technical specification using High Strength approved quality Cement and coarse granite aggregate conforming to Table 1000-1 including formwork as per Section 900,1000,1500,1700, 2100 of specifications for Road and Bridge works of Ministry of Road Transport & Highways (5th Revision) & including cost of all materials, labour, T&P, royalty etc complete in all respect and as per direction of the Engineer-in-charge. |
| 21 | Providing and laying Plain cement concrete of grade M-15 in sub-structure of CD works etc using 40mm to 10mm size crushed stone aggregates etc complete as per drawing and technical specification using High Strength approved quality Cement and coarse granite aggregate conforming to Table 1000-1 including formwork as per Section 900,1000,1500,1700, 2200 of specifications for Road and Bridge works of Ministry of Road Transport & Highways (5th Revision) & including cost of all materials, labour, T&P, royalty etc complete in all respect and as per direction of the Engineer-in-charge. |
| 22 | Providing, laying and fixing in position reinforced cement concrete 1000mm dia NP4 hume pipes for culverts on first class bedding of granular materials including pointing ends fixing collars with cement mortar 1:3 for finished item of work as per approved drawing and technical specifications complete in all respect as per Section 900, 1000 & 2900 of specifications for road and bridge works of Ministry of Road Transport & Highways (5th Revision) including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 23 | Gravel backing to revetments as per approved Drawing & Technical Specifications and as per Section 2500 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost, conveyance, royality & other taxes of materials, cost of labour, T&P etc complete. |
| 24 | Rough stone dry packing in aprons and revetments and stone pitching in slopes and boulder approns etc with hard granite stone of size 30 cm and above as per approved drawing and technical specifications complete in all respect as per Section 900, 1000 and 2500 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 25 | Providing and laying R.C.C M-20 grade in foundation as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 26 | Providing and laying R.C.C M-20 grade in wall as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 27 | Providing and laying R.C.C M-20 grade in column as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 28 | Providing and laying R.C.C M-20 grade in plinth as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 29 | Providing and laying R.C.C M-20 grade for column ground floor as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 30 | Providing and laying R.C.C M-20 grade for column first floor as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 31 | Providing and laying R.C.C M-20 grade for column second floor as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 32 | Providing and laying R.C.C M-20 grade for lintel ground floor as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 33 | Providing and laying R.C.C M-20 grade for lintel 1st floor as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 34 | Providing and laying R.C.C M-20 grade for lintel second as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 35 | Providing and laying R.C.C M-20 grade for Chhaja ground as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 36 | Providing and laying R.C.C M-20 grade for Chhaja first as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 37 | Providing and laying R.C.C M-20 grade for Chhaja second as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 38 | Providing and laying R.C.C M-20 grade for stair case ground as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 39 | Providing and laying R.C.C M-20 grade for stair case first as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 40 | Providing and laying R.C.C M-20 grade for roof beam ground as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 41 | Providing and laying R.C.C M-20 grade for roof beam first as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 42 | Providing and laying R.C.C M-20 grade for roof beam second as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 43 | Providing and laying R.C.C M-20 grade for roof slab ground as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 44 | Providing and laying R.C.C M-20 grade for roof slab first as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 45 | Providing and laying R.C.C M-20 grade for roof beam second as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 46 | Providing and laying R.C.C M-20 grade for cover slab as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 47 | Providing and laying R.C.C M-25 grade in sub-structure of CD works and retaining wall as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 48 | Providing and laying R.C.C M-25 grade in foundation of CD works and retaining wall as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 49 | Providing and laying R.C.C M-25 grade in columns as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 50 | Providing and laying R.C.C M-25 grade in super-structure as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 51 | Providing and laying R.C.C M-25 grade in super-structure column as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 52 | Providing and laying R.C.C M-25 grade in super-structure lintel as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 53 | Providing and laying R.C.C M-25 grade in fin as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 54 | Providing and laying R.C.C M-25 grade in roof slab as per approved drawing and technical specifications complete in all respect including formwork as per section 900, 1000, 1500, 1700, 2100 of MoRT&H specifications for Road & Bride works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 55 | Providing and laying R.C.C M-30 grade in wearing coat including cost of steel reinforcement for finished item of work as per approved drawing and technical specifications complete in all respect as per Section 900, 1000, 1500,1600, 1700 & 2702 of MoRT&H specifications for Road & Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 56 | Supplying, cutting, bending, binding, straightening, placing HYSD bars confirming to grade IS:1786-(Fe-500) for steel reinforcement works for finished item of work as per approved drawing and technical specifications complete in all respect as per section 900,1000 & 1600 of MoRT&H specifications for Road & Bridge works (5th Revision) including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 57 | Providing and laying of filter media/metal spall backing using 45mm size crushed hard granite stone aggregates to the required thickness with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall and return wall of CD works to the full height compacted to a firm condition as per drawing and technical specifications complete in all respect satisfying the requirements laid down in Clause 2504.2.2 and Section 900 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 58 | Providing weep holes in abutment, wing wall, retaining wall, toe wall and RCC drain etc with 100mm dia A.C. pipe as per approved drawing and technical specifications complete in all respect as per Section 2200 & Clause 2706 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 59 | Painting two coats with synthetic enamel paint of approved quality and shade over a coat of primer at any elevation on kerb, guard post and other structures etc for the finished item of work as per technical specifications complete in al lrespect as per Section 800 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 60 | Cement concrete (1:3:6) in foundation using 40mm size HGCB metal complete including cost of all materials and labour as per direction of the Engineer-in-charge |
| 61 | Cement Concrete (1:4:8) using 40mm size hard granite C.B. metal approved quality from approved quarry including hoisting laying using concrete mixture and vibrators including cost, carriage, royalty, cost of all labour T.&P. etc complete |
| 62 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. |
| 63 | Construction of reinforced cement concrete crash barrier of M-40 grade with HYSD reinforcement confirming to IRC-21 and dowel bars 25mm dia, 450mm long at expnasion joints filled with premoulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure of MOST Circular No. RW-NH-33022-1-94-DO-III dtd.24 June 1994 as per dimension in the approved drawing and location as per Clause 811 of MoRT&H specifications for Road & Bridge works (5th Revision) and as per direction of Engineer-in-Charge. |
| 64 | Providing and fixing drainage spouts in deck slab with 100 mm diameter G.I pipe for finished item of work as per approved drawing and technical specifications complete in all respect as per section 900 & Clause 2705 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. |
| 65 | Crash GATE |
| 66 | Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
| 67 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 68 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.(Ground Floor) |
| 69 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.(1st Floor) |
| 70 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.(2nd Floor) |
| 71 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 72 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(1st Floor) |
| 73 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(2nd Floor) |
| 74 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 75 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(1st Floor) |
| 76 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(2nd Floor) |
| 77 | 25 mm thick grading concrete (1:2:2) on roof slab with 6mm size C.B.H.G chips for old work per 1sqm and direction of Engineer-in-Charge. (1st Floor) |
| 78 | 25 mm thick grading concrete (1:2:2) on roof slab with 6mm size C.B.H.G chips for old work per 1sqm and direction of Engineer-in-Charge. (2nd Floor) |
| 79 | 25 mm thick grading concrete (1:2:2) on roof slab with 6mm size C.B.H.G chips for old work per 1sqm and direction of Engineer-in-Charge. (Ground Floor) |
| 80 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (Ground Floor) |
| 81 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (1st floor) |
| 82 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (2nd floor) |
| 83 | Wall painting two coats with weather coat of approved shade on new work over a coat of primer to give an even shade including cost of paint all labour T&P etc complete and direction of Engineer-in-Charge. |
| 84 | Provision for Y-Post for concertina wire fencing including cost, cnveyance, taxes, all labour etc. complete. |
| 85 | Cutting, bending, binding, laying MS Rod or Tor Steel in position etc complete.(Ground Floor) |
| 86 | Cutting, bending, binding, laying MS Rod or Tor Steel in position etc complete.(First Floor) |
| 87 | Cutting, bending, binding, laying MS Rod or Tor Steel in position etc complete.(Second Floor) |
| 88 | Supplying, fitting & fixing of Vitrified colour printed series tiles in floors of size 600mmx 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )(Ground) Floor) |
| 89 | Supplying, fitting & fixing of Vitrified colour printed series tiles in floors of size 600mmx 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )(First Floor) |
| 90 | Supplying, fitting & fixing of Vitrified colour printed series tiles in floors of size 600mmx 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )(Second Floor) |
| 91 | Supplying, fitting & fixing of Vitrified colour printed series tiles in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (Ground Floor) |
| 92 | Supplying, fitting & fixing of Vitrified colour printed series tiles in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (First Floor) |
| 93 | Supplying, fitting & fixing of Vitrified colour printed series tiles in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (Second Floor) |
| 94 | Supplying, fitting & fixing of CeramicTiles of minimum 16mm thick and above 0.10 sqm of approved make in floors over 25mm thick bed of cement mortar 1:1 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.(Data for 10 Sqm )(Ground Floor) |
| 95 | Supplying, fitting & fixing of CeramicTiles of minimum 16mm thick and above 0.10 sqm of approved make in floors over 25mm thick bed of cement mortar 1:1 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.(Data for 10 Sqm )(First Floor) |
| 96 | Supplying, fitting & fixing of Ceramic Tiles of minimum 16mm thick and above 0.10 sqm of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge(Ground Floor) |
| 97 | Supplying, fitting & fixing of Ceramic Tiles of minimum 16mm thick and above 0.10 sqm of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge(First Floor) |
| 98 | Supplying, fitting & fixing of Granite Tiles of minimum 16mm thick and above 0.10 sqm of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge.(Ground Floor) |
| 99 | Supplying, fitting & fixing of Granite Tiles of minimum 16mm thick and above 0.10 sqm of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge.(First Floor) |
| 100 | Supplying, fitting & fixing of Granite Tiles of minimum 16mm thick and above 0.10 sqm of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge.(Ground Floor) |
| 101 | Supplying, fitting & fixing of Prepolished cement concrete paving tiles of 22-25mm thick of make ultra, Eurocornor Duracrete in floors of size with application of 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) nd filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) ( Ground Floor) |
| 102 | Supplying, fitting & fixing of Prepolished cement concrete paving tiles of 22-25mm thick of make ultra, Eurocornor Duracrete in floors of size with application of 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) nd filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) ( First Floor) |
| 103 | Supply,Fabrication of Structural Steel truss structure in position at all levers and heights to the required size shape,alignment etc by using M,S Angles of SAIL/TATA/ZINDAL make including necessary Base/Cap Plate,Gusset Plate stiffener Plates Brackets Bolts Cleats Clit angles Nuts & Bolts Column cap Plate/bolt etc.All welding to be done by using structural steel welding including necessary epuipments tools & hackles etc all complete as per direction of the engineer -in-charge ( As per SP:38(S&T)-1987for Span-24.0mt) .(Details of truss attached in separate sheet).Supply,Fabrication of Structural Steel truss structure in position at all levers and heights to the required size shape,alignment etc by using M,S Angles of SAIL/TATA/ZINDAL make including necessary Base/Cap Plate,Gusset Plate stiffener Plates Brackets Bolts Cleats Clit angles Nuts & Bolts Column cap Plate/bolt etc.All welding to be done by using structural steel welding including necessary epuipments tools & hackles etc all complete as per direction of the engineer -in-charge ( As per SP:38(S&T)-1987for Span-24.0mt) .(Details of truss attached in separate sheet).(Ground Floor) |
| 104 | Hoisting Joists & Trusses & placing in Position Labour only(Ground Floor) |
| 105 | Providing and fixing pre-Painted Alu Zinc steel sheets (Galvalume) of 55% Aluminium 45% Zinc Alloy,semi Gloss/Matt finish conform to ASTM A792,A755,JIS G3321,G3322,AS1397 sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks bolts and 8mm diameter with bitumen and G.I limpat washers of G.I limpet washer filled with white lead and including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete(up to any pitch in horizontal/vertical or curved surfaces) excluding the cost of purlins rafters and trusses and including cutting size and shape wherever required including all acssories gutter down take pipe gable flashinh berge cap etc.(Ground Floor) |
| 106 | Supplying of M.S. Door, Window with grills, Grills made out of M.S. Angle frame, M.S. Flat, Sheet etc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete. (Ground Floor) |
| 107 | Wall Painting two coats with approved Distemper over a coat of Water Bound Wall cement Primer on Plastered Surfacein (Ground Floor) |
| 108 | Wall Painting two coats with approved Distemper over a coat of Water Bound Wall cement Primer on Plastered Surfacein (1st Floor) |
| 109 | Wall Painting two coats with approved Distemper over a coat of Water Bound Wall cement Primer on Plastered Surfacein (2nd Floor) |
| 110 | Providing Finished outside wall surface of walls with antifungal wheather coat of approved make and finished smooth and Even surface over a coat of wall primer including cost of materials, labour, T&P all comp. ( Ground Floor) |
| 111 | Providing Finished outside wall surface of walls with antifungal wheather coat of approved make and finished smooth and Even surface over a coat of wall primer including cost of materials, labour, T&P all comp. ( 1st Floor) |
| 112 | Providing Finished outside wall surface of walls with antifungal wheather coat of approved make and finished smooth and Even surface over a coat of wall primer including cost of materials, labour, T&P all comp. ( 2nd Floor) |
| 113 | Painting two coats enamel paint to the M.S. Window Grill/ Fixed Grill and Iron shutter with any approved shade over a coat of red oxide primer including cost of materials, labour, T&P all comp.(Ground Floor) |
| 114 | Painting two coats enamel paint to the M.S. Window Grill/ Fixed Grill and Iron shutter with any approved shade over a coat of red oxide primer including cost of materials, labour, T&P all comp.(1st Floor) |
| 115 | Painting two coats enamel paint to the M.S. Window Grill/ Fixed Grill and Iron shutter with any approved shade over a coat of red oxide primer including cost of materials, labour, T&P all comp.(2nd Floor) |
| 116 | Providing, fitting and fixing of Al door with anodized Al. door section of 9202 as vertical member, 9201 as top and 9200 as middle and bottom member with frame section No.9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle no. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges , etc. complete as per direction of the Engineer-in-charge (Ground Floor) |
| 117 | Supplying Fitting, fixing up fully glazed aluminium framed window (sliding type) made up aluminium section 9778 as window frame, section 4095, 4096 and 9777, 3994 as shutter frame with 5mm black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of all materials, all taxes, labour, T&P excluding cost of glass etc. complete as per direction of the Engineer-in-charge (Ground Floor) |
| 118 | Factory made single leaf rigid FRP (alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) mpregnated with orthopthalic polyester resin as per specification and direction of the Engineer in charge. (Ground Floor) |
| 119 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtrs C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc with coist, conveyance, taxes of all materials, labour and T&P required for the work all complete in all respect. (Ground Floor) |
| 120 | Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with water proof Gypsum board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge.(Ground Floor) |
| 121 | Dismantling brick or stone masonry in lime or cement mortar under 3mtr height including stacking the useful materials for reuse and removing the debris within 50m lead. Per 1 cum ( Ground floor) |
| 122 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made : Frame size- 65*125 mm(DAR Cl. 26.86.6)(Ground Floor) |
| 123 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete. ( Ground Floor) |
| 124 | Supplying, fitting & fixing of openable UPVC Doors with Door frame of approved make with 6mm thick glass of approved quality complete with frame . Shutters and all fittings and fixtures complete. (Ground Floor) |
| 125 | Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). (DAR 2021 vol-I Clause No-9.147D.4, pg no.518) ( Ground Floor) |
| 126 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made : Frame size 45 x 85 mm (DAR Cl. 26.86.2) ( Ground Floor) |
| 127 | 26.88 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of 30 mm thick of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainlesssteel butt hinges and necessary S.S screws shall be paid separately) (DAR 2023 vol-1,Cl 26.88, pg-2037)( Ground Floor) |
| 128 | Fixing chowkhat (Anchor Bolt) in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. ( Ground Floor) |
| 129 | Finishing surface of walls with Cement based wall putty & making smooth to recive painting including cost of scaffolding etc. with cost of all materials, labour T&P etc. complete. ( Ground Floor) |
| 130 | Finishing to the exposed surfaces of wall with weather coat of any approved shade on new work 2 coats over a coat of primer to give an even shade including cost of weather coat, primer all cost of all labours and T&P etc. complete . ( Ground Floor) |
| 131 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade over a coat of primer including cost of primer, paint etc complete. ( Ground Floor) |
| 132 | Painting 2 coats with any approved paint in iron works including sand papering, polishing surfaces, cost of paints, cost of all labour, T&P, etc complete in all floors as per direction of E.I.C. ( Ground floor) |
| 133 | Supplying, fitting & fixing of granite above 0.40 sqm (20mm thick) in floor on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) ( Ground Floor) |
| 134 | Supplying, fitting & fixing of granite above 0.40 sqm (20mm thick) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including cost of precast tiles. ( Ground Floor) |
| 135 | Enamel Painting two coats with aproved paint as per specification and standard etc. complete MS grill ( Ground Floor) |
| 136 | Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked (Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-guard) with 20 mm dia HMS FRLS PVC conduit ISI marked (Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal) 6A modular type ( flame retardant type) switch ISI marked (Make- Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision)) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retardant type) Make- Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistranded copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Group-A) |
| 137 | Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked (Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-guard) with 20 mm dia HMS FRLS PVC conduit ISI marked (Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal) 6A modular type ( flame retardant type) switch ISI marked (Make- Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision)) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retardant type) Make- Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistranded copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Group-B) |
| 138 | Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked (Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-guard) with 20 mm dia HMS FRLS PVC conduit ISI marked (Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal) 6A modular type ( flame retardant type) switch ISI marked (Make- Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision)) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retardant type) Make- Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistranded copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Group-C) |
| 139 | Supplying, fixing of 6A switch socket on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retardant type)) & other required accessories of ISI marked as approved as per direction of Eng. -in -Charge. Make- Schneider (Zencelo)/ legrand (Myrius)/ Panasonic (vision). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 140 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket (modular type) (flame retradant type)) with suitable size modular box & cover flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider (Zencelo)/ legrand (Myrius)/ Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 141 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in MS conduit of mentioned size as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia M S STEEL conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 142 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in MS conduit of mentioned size as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia M S STEEL conduit .(BDB to LSB/LIGHT CKT/5A PLUG/INVERTERPOINT TO EACH QTR) (2X2.5+1X1.5) |
| 143 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in MS conduit of mentioned size as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia M S STEEL conduit .(BDB to LSB/LIGHT CKT/5A PLUG/INVERTERPOINT TO EACH QTR) (2X2.5+1X1.5) |
| 144 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuity conductor in 32 mm dia non metallic heavy duty conduit. (LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 145 | S/F of Bakelite angle holder/batten holder (Make- Anchor/ Havells or equievalant reputed make A catagory ISI marked as approved ) of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 146 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) |
| 147 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Make:- Schneider/ Siemens/ Legrand/ ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 148 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/ Crompton/ Usha/ Orient/ Bajaj) of exhaust fan in the existing wall, including fixing & connection as required as per direction of Eng.-in-Charge. Replacement Warranty will be 2 years. |
| 149 | Supplying, installation, testing and commissioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery greater or equal to 215m3/min Make- Crompton Energion Groove/ Havells Efficiencia Neo/ Usha Technix/ Bajaj Turbo Pro 12DC5) including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Eng.-in-Charge, Replacement Warranty will be 4 years. |
| 150 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 151 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 152 | SITC of Street light- 120W,130 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66, IK 08 roadway luminaire with high power LED as light source with acrylic cover (Make: LT/ Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Panasonic) (5Years Warranty) |
| 153 | SITC of 200W FLAME PROOF HIGH BAY LED For gas group II A, II B,C , zone classification zone 1, zone 2, temp classification T6 with 120 lpw and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. Make-Crompton (FFL1315-200-CDL/60-HB-M)/equivalent model of LT/ Philips/ Wipro/ Havells/ Bajaj/ Panasonic |
| 154 | SITC of 200W FLAME PROOF HIGH BAY LED For gas group II A, II B,C , zone classification zone 1, zone 2, temp classification T6 with 120 lpw and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. Make-Crompton (FFL1315-200-CDL/60-HB-M)/equivalent model of LT/ Philips/ Wipro/ Havells/ Bajaj/ Panasonic |
| 155 | SITC of 200W FLAME PROOF HIGH BAY LED For gas group II A, II B,C , zone classification zone 1, zone 2, temp classification T6 with 120 lpw and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. Make-Crompton (FFL1315-200-CDL/60-HB-M)/equivalent model of LT/ Philips/ Wipro/ Havells/ Bajaj/ Panasonic |
| 156 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make- LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 157 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 158 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 159 | Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year |
| 160 | Supplying and fixing 40Amps 2P 240 volts AFDD(arc fault detection device) Make- ABB S ARC1 M/ Equivalent model of Schneider/ Legrand/ Siemens IEC-62606 for arc fault in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year |
| 161 | Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board, Make-Legrand/ Siemens/ Schneider/ OBO/ DEHN in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 1 year. |
| 162 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 163 | Providing and fixing 50 mm X 5 mm dia G.I strip on wall/surface With required DMC insulator and nut bolt connection etc. as required. |
| 164 | Providing and fixing 25 mm X 5 mm dia G.I strip on wall/surface With required DMC insulator and nut bolt connection etc. as required. |
| 165 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells / KEI/ Gloster/ Finolex/ RR Kabel)3.5 Core x 50 Sq mm |
| 166 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells / KEI/ Gloster/ Finolex/ RR Kabel)4Core x 16 Sq mm |
| 167 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required. (Upto 25 sq. mm) |
| 168 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required. (Upto 25 sq. mm) (Above 25 sq. mm and upto 120 sq. mm |
| 169 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. (Upto 25 sq. mm) |
| 170 | Above 25 sq. mm and upto 120 sq. mm |
| 171 | Supplying & Testing of 1.1 KV grade Cu XLPE Un Armoured (Flexible) power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells/ KEI/ Gloster/ Finolex/ RR Kabel)3C x 2.5Sqmm |
| 172 | Providing,fixing and laying of 25 MM PVC (medium class) in ground complete with HDPE fitting incl. trenching (75 mm depth) and refilling as per direction of Engg.-in-Charge. |
| 173 | Hanger Main Panel:- S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication. Mandatory provision of cable alley is to be given.Incommer-1-01 number of 160A 4P MCCB, 25Ka MCCB withTMR based release with adjustable overload, Icu=100%Ics (Make- Legrand-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)1Set of -160 4P Onload changeover (Make:- Legrand, siemens, ABB,Schneider)Busbar-1&2 04 numbers of 200Amps AL. busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 6 numbers 63 A 4P MCB, 10kA, C series for DBs.2 nos. of 100 4P MCCB 16Ka withTMR based release with adjustable overload, Icu=100%Ics Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data(iv)1 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB (Make- Legrand/ Siemens/ Schneider/ ABB/ OBO/ DEHN) |
| 174 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required. Make- Safex/ Fireshield/ Ceasefire/ Flameklog |
| 175 | Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required. (Make-Safex/ Fireshield/ Ceasefire/ Flameklog) |
| 176 | Supply of 3 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with double arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 177 | Supply of all materials, labour, T&P and transporation for providing earth work, filling in foundation with clean coarse river sand, RCC M-20 using 12mm size hard granite Stone Chips with centering, shultering including cutting, bending, binding & tying the Grills and cost of M.S. Rod, binding wire, providing 6mm thick Cement plaster finished smooth over RCC surface, painting two coats of paint with weather proof cement paint over one coat of primer and carriage of excavated materials within 5 kms lead by mechanical means with cost, conveyance, royalty, taxes etc. all complete as per the OPWD specification & direction of Engineer in charge. (For Foundation & erection of Supply and erection of 3 mtr long double arm Ornamental Decorative Poles) |
| 178 | SITC of 50W Outdoor Flood LED lights with polycarbonate module lens provided with silicon gasket for efficient ingree protection with silicon potted driver, IP66, IK08 , bottom opening maintanance , LPW not less than 120.Input Voltage: 85-265V AC ,Body : pressure Die cast Aluminium housing designed to act as heat sink for proper heat dissipation, IP66, CRI greater than eual to 70, burning hours 50,000 hrs, pf greater than 0.95, THD less than 10% as per the Drawing for inspection as required Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired & as per direction of Engg.-in-Charge. The luminaire should be Replacement Warranty will be 2 years . |
| 179 | Supply, fitting and fixing of Coil Earthing etc. complete with transportation, T&P and labour charges as per the direction of the Engineer-in-Charge. |
| 180 | Supply and fixing of in built junction box with 4WAY connector & 16Amp.2P MCB in each pole as per the direction of the Engineer-in-Charge. |
| 181 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells/ KEI/ Gloster/ Finolex/ RR Kabel) |
| 182 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells/ KEI/ Gloster/ Finolex/ RR Kabel)4 Core x 16 Sq mm |
| 183 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells/ KEI/ Gloster/ Finolex/ RR Kabel)3.5Core X 35 Sq Mm |
| 184 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required.Upto 25 sq. mm |
| 185 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required.3.5Core X 35 Sq Mm |
| 186 | Supply and laying of 40mm\\" OD HDPE Pipe for laying of cable under 700mm (depth may vary as per side condtion) including cost of materials, labour, T&P and transportation as per direction of the Engineer-in-Charge. For Laying of cable for power supply from LT Pole to outdoor Feeder Panel and interconnection of road for the 3 mtr long Double arm Ornamental Decorative Poles as per direction of the Engineer-in-charge. |
| 187 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A FP MCCB, 16kA, tmr, Ics=100%Icu 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 188 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 189 | Upto 25 sq. mm |
| 190 | 3.5Core X 35 Sq Mm |
| 191 | FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. *It also includescontrol cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work)Upto 25 sq. mm |
| 192 | FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. *It also includescontrol cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work)3.5Core X 35 Sq Mm |
| 193 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 194 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 195 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 196 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 197 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 198 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make- OBO/ Dehn/ ABB |
| 199 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 200 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB |
| 201 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 202 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 203 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 204 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 205 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 206 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 207 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 208 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 209 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 210 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 211 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 212 | Out going- 2 numbers of 160A 4P MCCB,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics (Make-Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formulla)Out going- 3 numbers of 125A 4P Icu=100%Ics,,25Ka MCCB withTMR based release with adjustable overload (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Out going- 2 numbers of 100A 4P Icu=100%Ics,,25Ka MCCB withTMR based release with adjustable overload (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Out going- 2 numbers of 63A 4P Icu=100%Ics,,25Ka MCCB withTMR based release with adjustable overload (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Outgoing- 1 no. 400 A 4P MCCB 36 KA,Ics=100%Icu, LSIG MCCB with micro processor based release TO DG AMF (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Outgoing- 1 no. 250 A 4P MCCB 36 KA,Ics=100%Icu, LSIG MCCB with micro processor based release For fire (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage, current, frequency, PF, THD indication with RS 485 COMPACTIVITY FOR bms data(iii) all the outgoing MCCB feeders shall have digital ammeter with class 1 CT of suitable rating(iv)2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB (Make- Legrand/ Siemens/ Schneider/ ABB/ OBO/ DEHN) Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (flame retardant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider (Zencelo)/ legrand( ( Myrius))/ Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 213 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retardant type)) with suitable size modular box & cover(flame retardant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/ legrand(Myrius)/ Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 214 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal as required as per direction of Eng.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit. (2X1.5+1X1.5) |
| 215 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal as required as per direction of Eng.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5) |
| 216 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal as required as per direction of Eng.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit . (2X4+1X1.5) |
| 217 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal as required as per direction of Eng.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuity conductor in 25 mm dia non metallic heavy duty conduit . (2X6+1X2.5) |
| 218 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal as required as per direction of Eng.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuity conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) |
| 219 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 220 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 221 | Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 -50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . |
| 222 | Supplying and fixing of Energy efficient surface /recess mounted Decorative 15W Wall light, and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. .The luminaire should be Replacement Warranty will be 2 years Model: Philips Ebony-582063 /Equivalent model of Panasonic/ LT/ Havells / Wipro/ Crompton/ Bajaj |
| 223 | Supplying and fixing of 45 W ,3000K flexible led strips with uniform light distribution and long lasting adhesive for perfect cove lighting solution including all , Energy efficient surface /recess mounted and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 224 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years8Way(8+(4x3)+(8x3)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-24 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 225 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Make- LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ ABB Itus Warranty on DB is 3 years |
| 226 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 227 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 5 Star Inverter Type - Cooling only (Category II Make :- O General/ Daikin)Supplying and fixing of 5KVA Voltage stabilizer (90V - 300V) ISI Marked. (Make:- V-Guard/ MICRO-TECH). |
| 228 | Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 229 | Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. 25mm nom. Dia pipe |
| 230 | Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job. |
| 231 | S/F of 2 Kva Inverter with 24V Tubular Battery with (2 nos) 200 Ah with trolley Make: luminous/ Exide/ Microtek/ V Guard |
| 232 | Supply,installation,testing and commissioning of 12M high mast shaft in two sections suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 6 luminaires in symmetrical arrangement and other accessories manufactured in factory. ( Bottom 360mm / Top -150mm, 3mm thickness, 445PCD, diameter of base plate 520mm including supplying of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation)along with foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template along with Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour . Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) Approved colour after treatment along with provision of masonary pedestal duly finished with plaster and painting with GI pipe for cable entering as required.. (2nos per mast required) (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT/Valmont |
| 233 | SITC of 250W Outdoor Flood LED lights with polycarbonate module lens provided with silicon gasket for efficient ingree protection with silicon potted driver, IP66, IK08 , bottom opening maintanance , LPW not less than 120.Input Voltage: 85-265V AC ,Body : pressure Die cast Aluminium housing designed to act as heat sink for proper heat dissipation, IP66, CRI greater than eual to 70, burning hours 50,000 hrs, pf greater than 0.95, THD less than 10% as per the Drawing for inspection as required Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired & as per direction of Engg.-in-Charge.The luminaire should be Replacement Warranty will be 2 years . |
| 234 | Supply, fitting and fixing of Automatic feeder pillar panel Outdoor type I/c: 63 Amp mccb,63 Amp-Busbar,O/G: 40 Amp Contactor-02 Nos, Auto Manual Timer-01 Nos,Volt Meter,Amp Meter,Indicator Switch ,Reverse Forward Switch SPD-Upto 5 Kv Surge Protection ,Complete with wiring and all. Make of MCCB-Legrand-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula Make of SPD-Legrand/ABB/Siemens/Schneider/OBO/DEHN |
| 235 | Supply, fitting and fixing Double dome aviation light etc. complete with transportation, T&P and labour charges as per the direction of the Engineer-in-Charge. |
| 236 | Supply and laying of 4core x 16 sq mm PVC insulated PVC sheathed armoured over head aluminum armoured cable for interconnection of power supply for the 3 mtr long double arm Ornamental Decorative Poles to Pole including cost of materils, labour, T&P and transportation etc. complete as per direction of the Engineerir-in-charge. (Make:- Polycab/ Havells/ KEI/ Gloster/ Finolex/ RR Kabel)Upto 25 sq. mm |
| 237 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 238 | Providing and fixing 50 mm X 5 mm dia G.I strip on wall/surface With required DMC insulator and nut bolt connection etc. as required. |
| 239 | Providing and fixing 25 mm X 5 mm dia G.I strip on wall/surface With required DMC insulator and nut bolt connection etc. as required. |
| 240 | SITC of 200W Outdoor Flood LED lights with polycarbonate module lens provided with silicon gasket for efficient ingree protection with silicon potted driver, IP66, IK08 , bottom opening maintanance , LPW not less than 120.Input Voltage: 85-265V AC ,Body : pressure Die cast Aluminium housing designed to act as heat sink for proper heat dissipation, IP66, CRI greater than eual to 70, burning hours 50,000 hrs, pf greater than 0.95, THD less than 10% as per the Drawing for inspection as required Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired & as per direction of Engg.-in-Charge.The luminaire should be Replacement Warranty will be 2 years . |
| 241 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5 x25 sqmm |
| 242 | Supplying and fixing of Four pole 32 Amp MCB Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 with sheet matal Enclosure. |
| 243 | Watch Tower Panel:- S/I/T&Commissioning of LT outdoor floor mounted cubical type electrical Watch Tower panel (for light and Power) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 40ka with 63A rating, 10KA breaking capacity, 4P MCB shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. In commer- 01 no 63A 4P MCCB 16kA, TMR, Ics=100%Icu (Make- Legrand-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula), Busbar-1&2 04 numbers of 100Amps Cu. busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) , Out going- 07nos 32A DP MCB 10kA,C series. cable alley with 100A 7 nos. stud connector. Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200, Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 3 ph digital type Voltmeter (Make-Siemens/ Schneider/ ABB/ Legrand). (iii)01 set of 3 ph digital type Ammeter(0-100)A (Make-Siemens/ Schneider/ ABB/ Legrand) with CTs 100/5A 3 nos class 1 type |
| 244 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 5 Star Inverter Type - Cooling only (Category II Make :- O General/ Daikin)2.0 TR with 5 Star BEE Rating (O General-ASGG24CGWA-B/ Daikin-FTKM60XV16) |
| 245 | Terminal Building Panel:- S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for Bulding Power and Light ) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40ka with 63A rating,10KA breaking capacity ,4P MCB shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.In commer- 01 no 125A 4P MCCB 16kA (Make- Legrand-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)1Set of change over - 63A 4P Onload Changeover (Make :- Legrand/ Siemens/ ABB/Schneider)Busbar-1&2 04 numbers of 160Amps Cu. busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) , Out going- 03 no 63A 4P MCB 10kA ,C series with on/off trip indication Light load for each floor. (Make- Legrand-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200)Out going- 03nos 40A DP MCB 10kA,C series. Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200, Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 3 ph digital type Voltmeter (Make-Siemens/ Schneider/ ABB/ Legrand). (iii)01 set of 3 ph digital type Ammeter(0-100)A (Make-Siemens/ Schneider/ ABB/ Legrand) with CTs 100/5A 3 nos class 1 type. From Transformer to Temporary Terminal Building |
| 246 | Supply,installation,testing and commissioning of 12M high mast shaft in two sections suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 6 luminaires in symmetrical arrangement and other accessories manufactured in factory. ( Bottom 360mm / Top -150mm, 3mm thickness, 445PCD, diameter of base plate 520mm including supplying of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation)along with foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template along with Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour . Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) Approved colour after treatment along with provision of masonary pedestal duly finished with plaster and painting with GI pipe for cable entering as required.. (2nos per mast required) (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT/Valmont |
| 247 | Out going- 2 numbers of 160A 4P MCCB,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics (Make-Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formulla)Out going- 3 numbers of 125A 4P Icu=100%Ics,,25Ka MCCB withTMR based release with adjustable overload (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Out going- 2 numbers of 100A 4P Icu=100%Ics,,25Ka MCCB withTMR based release with adjustable overload (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Out going- 2 numbers of 63A 4P Icu=100%Ics,,25Ka MCCB withTMR based release with adjustable overload (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Outgoing- 1 no. 400 A 4P MCCB 36 KA,Ics=100%Icu, LSIG MCCB with micro processor based release TO DG AMF (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Outgoing- 1 no. 250 A 4P MCCB 36 KA,Ics=100%Icu, LSIG MCCB with micro processor based release For fire (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage, current, frequency, PF, THD indication with RS 485 COMPACTIVITY FOR bms data(iii) all the outgoing MCCB feeders shall have digital ammeter with class 1 CT of suitable rating(iv)2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB (Make- Legrand/ Siemens/ Schneider/ ABB/ OBO/ DEHN) |
| 248 | Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge25mm dia PVC ASTM pipe (sch-80) |
| 249 | Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge32mm dia PVC ASTM pipe (sch-80) |
| 250 | Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge50mm dia PVC ASTM pipe (sch-80) |
| 251 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock (FLR-ACR-5053N) |
| 252 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP two in one bib cock (FLR-ACR-5041N) |
| 253 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 254 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 255 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
| 256 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.25mm dia brass full way valve (Shakti make) |
| 257 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.32mm dia brass full way valve (Shakti make) |
| 258 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
| 259 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.125mm CP grating |
| 260 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm size C.P. flange |
| 261 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.Gyser ELM-WHT-V006 |
| 262 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank |
| 263 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 264 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge |
| 265 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
| 266 | Supplying the waterproofing material Cementetious base Water proofing Pidifin 2K of Dr.fixit or equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. |
| 267 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 268 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC P Trap(Ori Plast/Finolex/Supreme Make) |
| 269 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 270 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 271 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 272 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 273 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC HR Bend(Ori Plast/Finolex/Supreme Make) |
| 274 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 275 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 276 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make) |
| 277 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 278 | Supply and installation of Rimless Back To Wall WC With UF Soft Close Slim Seat Cover, Hinges, Fixing Accessories And Accessories Set, Size: 340x560x400mm, P-Trap:180mm ARS-WHT-39955P180UFSM, JAQUAR MAKE |
| 279 | Supply and installation of Single Piece Slim Concealed Cistern Body with Installation Kit & S-Type drain pipe connection set for Wall Hung WC (without Flush Control Plate) JCS-WHT-2400S,JAQUAR MAKE |
| 280 | Supply and installation of Control Flush Plate Aria JCP-CHR-392415,JAQUAR MAKE |
| 281 | Supply and installation of Table Top Basin,Size: 700 x 435 x 135mm ARS-WHT-39903, JAQUAR MAKE |
| 282 | Supply and installation of Maze Overhead Shower 300X300mm Square Shape Single Flow (Body & Face Plate Stainless Steel) with Rubit Cleaning System (OHS-CHR-1639) JAQUAR MAKE |
| 283 | Supply and installation of Shower Arm 400X25X25mm Square Shape for Wall Mounted Showers with Flange (SHA-CHR-455L400) JAQUAR MAKE |
| 284 | Supply and installation of 8 mm thick sliding glass door of size 2mX2m Optima Standard - (Width : 2000) JSE-CHR-OPTSDR2000SX of Jaquar make. |
| 285 | Supply and installation of single lever exposed part kit of highflow Diverter constisting of operating lever, cartridge sleeve, wall flange ( with seal), Button Assembly Sleeve & Button (compatible with ALD-079) ARI-39079NK, ARIA-JAQUAR |
| 286 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24inch x 18inch x 10inch sink |
| 287 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 288 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeTowel ring |
| 289 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails. |
| 290 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.600mmx450mm size B.E mirror (swivelled type) |
| 291 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge.Inside size 76cmx76cmx46cm with 18inch dia RCC MH cover |
| 292 | Supplying all materials labour T&P and providing and fixing Eproxy Grount etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 293 | Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. |
| 294 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 295 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge )Kajaria tile 60cmx120cm |
| 296 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 297 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge )Kajaria tile 60cmx120cm |
| 298 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 299 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 300 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge.100mm dia P.V.C. pipe |
| 301 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge.150mm dia P.V.C. pipe |
| 302 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18inch dia RCC Cover ) |
| 303 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 304 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. 1 x 4.70 x 3.30m x 0. 70 |
| 305 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. 1 x 4.70 x 2.30m x 0.15 = |
| 306 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 307 | Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete.1 x 4.70 x 2.30 x 0.15 = |
| 308 | Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete. |
| 309 | Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site. |
| 310 | Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. 1.013cum x 2,5 x 35.32 =89.44 say Rs- |
| 311 | Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor. |
| 312 | Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site. |
| 313 | Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site. |
| 314 | Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site.same as plastering |
| 315 | Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. |
| 316 | Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. |
| 317 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. |
| 318 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 30mtr |
| 319 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore.30 mtr to 45mtr |
| 320 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 150mm dia bore45 mtr to above |
| 321 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.200mm dia PVC pipe.00 mtr to 45 mtrs |
| 322 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.200mm dia PVC (sch-80) pipe |
| 323 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 324 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in chargeBy DTH Rig |
| 325 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:Rocky terrain with boulder formation for 300m depth |
| 326 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)2 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm |
| 327 | DOL Control panel |
| 328 | 40mm dia steel short piece |
| 329 | Well cap |
| 330 | 50mm size CI bracket |
| 331 | 2.50sqmm flat cable |
| 332 | Steel rope with cover |
| 333 | Labour charges for lowering including transportation |
| 334 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.32mm HDPE pipes (Finolex/Supreme make) |
| 335 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 336 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge.150mm dia P.V.C. pipe |
| 337 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge.Inside size 76cmx76cmx46cm with 18inch dia RCC MH cover |
| 338 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail