| 1 | DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group C |
| 3 | DSR Item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 4 | 25 mm |
| 5 | DSR Item No 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 2.5 sq. mm |
| 8 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | 5/6 amps switch |
| 10 | 3 Pin 5/6 A. socket outlet |
| 11 | 15/16 amps switch |
| 12 | 6 Pin 15/16 A. socket outlet |
| 13 | DSR item No.1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 14 | DSR item No.1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 15 | DSR item No.1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 16 | 1 or 2 Module |
| 17 | 3 Module |
| 18 | 6 Module |
| 19 | 8 Module |
| 20 | 12 Module |
| 21 | DSR item No.15.16 SupplyingandlayingoffollowingsizeDWCHDPEpipeISI markedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningandprotectivecoveringetc.,completeasrequired. |
| 22 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 23 | DSR item No.15.15Supplying and laying of following sizeDWC HDPE pipe ISImarkedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 24 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 25 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Triple pole and neutral |
| 27 | DSR item no. 8.6.10LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 11 of the DNIT). |
| 28 | 36 watt |
| 29 | DSR item no. 8.7.10LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 12 of the DNIT). |
| 30 | 36 watt |
| 31 | DSR item no.8.16.5LEDFlood powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt)Supplying,installation,Testing&CommissioningofFlood Light,powdercoatedpressuredie cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 13 of the DNIT). |
| 32 | 200 Watt |
| 33 | DSR item No.8.2.4LED Down lighter (SMD Type) (System lumen efficacy ≥120<135 lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 14 of the DNIT). |
| 34 | 18 watt |
| 35 | Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. (As per Complete Item No. 15 of the DNIT). |
| 36 | S/I/T/C of linear suspended luminaire 4 ft. long made up of extruded aluminium with PMMA diffuser for standalone and seamless end to end connectivity. The fitting is to be installed on existing surface with the help of 2 no. suitable length universal suspensions suitable for quick on site adjustment. (As per Complete Item No. 16 of the DNIT). |
| 37 | Supply and Erection of LED Post Top Lantern fittings made of cast aluminium housing with power to be mounted on directly on inbuilt Heat sinks. A UV stabilized PC/PMMA diffuser is provided for Glare Free Lighting with high visual comfort to complete with Electronic LED Driver Power supply & related accessories with the following specifications to be installed on existing pole. |
| 38 | S/E of Cement Collar and Jn. Box at the base of the pole with the detailed specification as given below: Jn. Box Construction:S/E of Thermo Plastic cable Jn. Box IP55 of size 155x210x92 mm deep (approximate) with 4 nos. thermal block suitable for 1 no. incoming and 3 nos. outgoing cables. (As per Complete Item No. 18 of the DNIT). |
| 39 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing RCC/Hume/DWC/ Metal pip(As per Complete Item No. 18 of the DNIT). |
| 40 | Size 10 Sq.mm 4 Core XLPE Al. Arm. Cond. Cable |
| 41 | Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. (As per Complete Item No. 20 of the DNIT). |
| 42 | Size 10 Sq.mm 4 Core XLPE Al. Arm. Cond. Cable |
| 43 | Supply & erection of sheet metal distribution board of suitable size of required number of ways for mounting Miniature Circuit Breaker/ Isolators including connection & bonding to the existing earth etc. as required to the entire satisfaction of EIC. The DB should be of L&T / Legrand/ Schneider/ Siemens/ ABB make only. |
| 44 | Sheet metal SP&N Distribution board (dust protected) provided with din bar suitable for incorporating MCB’s/Isolator 3 way/ 4 way. |
| 45 | Supply & erection of Cabin Fan 16” sweep (metal body) oscillating type complete with aluminium blades & regulator. The fan should have regulator switch for speed regulation. (As per Complete Item No. 22 of the DNIT). |
| 46 | Labour charges for horizontal boring 1 Mtr. below ground level including cost of 2 Nos. pit digging and refilling complete in all respect to the entire satisfaction of EIC. |
| 47 | S/E of Thermo Plastic cable Jn. Box IP55/65 of size 155x210x92 deep (approximate) with 4 nos. thermal block suitable for 1 no. incoming and 3 nos. outgoing cables. (As per Complete Item No. 24 of the DNIT). |
| 48 | Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S. flat 50 mm X 6 mm thick of suitable length duly welded. (As per Complete Item No. 25 of the DNIT). |
| 49 | Cubical size 750 mm X 600 mm X 200 mm |
| 50 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 51 | 4 way (4 + 12) Double door |
| 52 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 53 | Single pole |
| 54 | Triple pole and neutral Please Enable Macros to View BoQ information |