| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls/RCC footing shutters : Under 20 cm wide complete in all respect as directed by the Engineer - in - Charge. |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete complete in all respect as directed by the Engineer - in - Charge. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts complete in all respect as directed by the Engineer - in - Charge. |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or superstructure .Thermo-Mechanically Treated bars of grade Fe-500D or more as directed by the Engineer - in - Charge. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level or superstructure : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond CRRI campus, for all leads including all lifts involved. Complete as directed by the Engineer in Charge. |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 12 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 13 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, including cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats) |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 15 | 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 17 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 18 | Supply & installation of 40 feet long, 8 feet width and 9 feet 6 inch height new metal container with eight corner fittings and two sets of fork lift pockets in the bottom structure with - (i) LED Tube light (20 Watt) near side door of the main Storage Room with standard Electrical fittings along with ON/OFF switches.(ii) Wire Ropes for lifting (for 4 corners)(iii) Exhaust fan (300mmx300mm) with Louvers watertight covers and ON/OFF switches. (03 Nos.)(iv) Ventilator window with Sliding Door (Watertight), (Qty. - 03 Nos. of Standard Size)(v) Main power supply box along with Electrical Cables with Suitable Glands and junction box.(vi) 6/16 Amp 6 pin multi socket with ON/OFF switch.(vii) Electrically insulate rubber floor with minimum thickness 8mm at Distribution board.(viii) Wall insulation with good quality Grade incombustible material. (Eg – Rockwool, minimum thickness – 50mm)(ix) Arrangement for provision of Air Conditioning(x) Doors along with Door Closers(xi) Wall Mounted Fan(xii) Earthing with BFC based chemical compound.The item shall be delivered as per the Complete Specifications. Please Enable Macros to View BoQ information |