| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 2 | Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, emoval of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil 11-1-1-1 |
| 3 | Excavation in foundation for retaining,breastwallsetc, inall typesofsoils and rocks includingall lead, lift anddisposal of surplusmaterial asper direction of engineer- in- charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction |
| 4 | RandomRubbleStoneMasonry laid in1:6cement andsandmortar, inbreastwalls,retainingwalls,parapets,scuppers,etc. includingsupplyofallmaterial, labour, T&Pand royaltiies etc. complete as per drawingandtechnical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 5 | 1-3 Random Rubble Stone Masonry laid Dry, in breastwalls, retaining walls,etc. including supply of all material, labour, T&P and royaltiies etc.complete as per drawing and technical specifications Clauses 702, 704,1202 & 1203 of MORD Specifiction |
| 6 | Deduction for old available stone assuming 30% stone of damaged wall will be reusable in new Random Rubble Masonry wall |
| 7 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand) |
| 8 | HandPacked stonefilling in back of wallls including cost of all materials,royality,T&Petc.complete as per direction of Engineer-in-charge. (Asper PWD Uttarakhand specifications) |
| 9 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20Nominal mix (1:2:4) |
| 10 | Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 11 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 12 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conformingto IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketedpipes. 150.mm dia (AS PER LOWEST QUATATION) |
| 13 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 10.25.2 |
| 14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 15 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 16 | Plastering with cement mortar (1:4), 15 mm thick as per technical specification Clauses 613.4 & 1204 |
| 17 | providing and laying in position cement concrete of specfic grade excluding the cost of centering and suttering -all work upto plinth level:derived from natural source 3 graded stone aggregate 20mm nominal size derived from nominal source 1:1½:3 (1 Cement: 1% coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | FG LIGHTS 12 Watt WHITE-LED BASED SOLAR STREET LIGHTING SYSTEM With 30 Ah Battery CapacityFG LIGHTSR(DPSO001) |
| 19 | S/f of sign board & photograph Please Enable Macros to View BoQ information |