| 1 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed. |
| 2 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- Make of cable : Plaza/Polycab/Finolex/ Havells |
| 3 | One light/ fan/ exhaust fan/ buzzer point controlled by one switch. |
| 4 | One 3 pin socket outlet 6 Amps, Independent board with cables 1.5 Sqmm size. |
| 5 | One 3 pin socket outlet 6 Amps,same board with cables 1.5 Sqmm size. |
| 6 | One light point controlled by two 2- way switches, with cable 1.5 Sqmm size. |
| 7 | All as per item ser no-2 above here in before but one 3 pin socket outlet 6/16 Amps, indipendent board with cables 4.0 Sqmm size.Make :- Polycab/Finolex/Plaza/Havells |
| 8 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor drawn into PVC Conduit and Casing & caping fixed on wall/roof/ceiling including wall cutting etc of size not less than 20 mm dia including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :- Make for PVC casing & caping: SUDHAKAR / AVON PLAST /PLAZA , Make for Copper cable: Finolex/Polycab / Plaza. |
| 9 | One light point controlled by one switch. |
| 10 | One 3 pin socket outlet 6 Amps, indipendent board with cables 1.5 Sqmm size. |
| 11 | All as per item ser no-4 above here in before but one 3 pin socket outlet 6/16 Amps, indipendent board with cables 4.0 Sqmm size. Make :- Polycab/Finolex/Plaza |
| 12 | M&L for sub main wiring for phase and neutral with PVC FRLS insulated unsheathed multi stranded along with earth wire FRLS PVC insulted copper conductor, single core cable in and including surface/concealed /PVC conduit appropriate size including cutting chases on brick walls concrete if required/ necessary surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishesas specified for the following sizes. Make for Copper cables: Finolex/Polycab / Plaza/ Havells. Make of PVC Conduit: SUDHAKAR/FINOLEX/AVON PLAST. |
| 13 | 2x 1.5 sqmm and 1x 1.5 sqmm as earth wire |
| 14 | 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire |
| 15 | 2x 6.0 sqmm and 1x 6.0 sqmm as earth wire |
| 16 | 2x 10.0 sqmm and 1x 10.0 sqmm as earth wire |
| 17 | 4x 10.0 sqmm and 2x 10.0 sqmm as earth wire |
| 18 | 4x 16.0 sqmm and 2x 16.0 sqmm as earth wire |
| 19 | Taking down existing rusted switch board sunken box from site including removing fixtures and fittings such as switch, socket fan regulator complete, removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces necessary plaster, white wash matches with existing colour of wall, floors, etc. all as specified and as directed. |
| 20 | Supply and fixing in repair of GI metal flush box suitable for mounting moduler plate of following modules:- |
| 21 | 1 or 2 Module |
| 22 | 3 Module |
| 23 | 4 Module |
| 24 | 6 Module |
| 25 | 8 Module |
| 26 | 12 Module |
| 27 | Supply and fixing in repair of combined both frame and cover plates fixing on mounting boxes for following modules:- |
| 28 | Cover plate with frame,2 Module |
| 29 | Cover plate with frame,3 Module |
| 30 | Cover plate with frame,4 Module |
| 31 | Cover plate with frame,6 Module |
| 32 | Cover plate with frame,8 Module |
| 33 | Cover plate with frame,12 Module |
| 34 | Supply and fixing in repair of modular switch one way 6A white Active one module all as specified and as directed by the Engineer-in-Charge |
| 35 | Supply and fixing in repair of modular fan step regulator,120 W-2 module all as specified and as directed by the Engineer-in-Charge.Make: Havells(Crabtree)/Legrand/Plaza. |
| 36 | Supply and fixing in repair of modular socket 6A, 3 pin combined two module all as specified and as directed by the Engineer-in-Charge |
| 37 | Supply and fixing in repair of modular switch 16A, 3 pin combined two module all as specified and as directed by the Engineer-in-Charge |
| 38 | Supply and fixing in repair of modular socket 16A, 3 pin combined two module all as specified and as directed by the Engineer-in-Charge |
| 39 | Supply and fixing in repair modular bell push 6A one module complete all as specified and as directed. |
| 40 | S&F in repair for switch socket combination 2 in 1, 3/5 pin, 6 Amp flush type with gang box complete all as specified and as directed by Engr-in-Charge Make: Anchor/Cona/Leader |
| 41 | S&F in repair for switch socket combination 2 in 1, 5/6 pin, 6 and 16 Amp flush type universal including gang box complete all as specified and as directed by Engr-in-Charge Make: Anchor/Cona/Leader |
| 42 | Supply and fixing in repair of modular switch socket combination 16 A, 5/6 pin 3 module including gang box flush type Active white two module complete all as specified and as directed by the Engineer-in-Charge .Make: Havells(Crabtree)/Legrand/Plaza. |
| 43 | Supply and fixing in repair of modular switch socket combination 6 Amp, 3/5 pin flush type including gang box Active white two module complete all as specified and as directed by the Engineer-in-Charge.Make: Havells(Crabtree)/Legrand/Plaza. |
| 44 | Supply and fix Energy saving not less than 35 Watts LED light fitting ,IP66 powder coated pressure die cast aluminium high power street light with heatresisant toughened glass with lens by providing GI pipe medium grade 25 mm dia 1.5 Mtr in length with suitable size MS Clamp two nos made out of 25x3 mm FI incl two coat of synthetic enamel paint over a coat of red oxide primer, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm from ceiling rose to fitting and including taking down old u/s damaged all as specified. Make Surya/Havells/Philips/CROMPTON. |
| 45 | Supply and fix Eco compact wall mounted LED batten for T8 LED tube with ULTRON high efficency LED polycarbonate tube with in built driver and metal heat sink 20/22 watt icluding taking down old unserviceable fittings all as specified and as directed by Engr-in-Charge.Make : Crompton /philips/ wipro/ Havells/Surya |
| 46 | Supply and fix high efficiency wall mounted LED batten type polycarbonate tube of 10W 2 ft LED and including taking down old unserviceable fittings all as specified and as directed by Engr-in-Charge . Make : Havells/ Philips/Crompton/wipro/ Surya. |
| 47 | S&F MCB,DB SPN 02 way in SS enclosure type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.Make: Legrand/ Siemens/Scheneider/ABB. |
| 48 | Supply and fix for MCB SPN 230 V, 40-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABBNote : Including taking down old unserviceable. |
| 49 | Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C urve complete all as specified and as directed by Engr-in-chargeMake: Legrand/ Siemens/Scheneider/ABBNote : Including taking down old unserviceable. |
| 50 | S& F for modular sheet metal enclosure double pole and neutral with a three pin and earth plug and socket complete with one SP MCB 25-32 Amps. Make: Legrand/ Siemens/Scheneider/ABB Please Enable Macros to View BoQ information |