| 1 | Cleaning of overhead water tanks (RCC/PVC) of any description and capacity of the tank exc. 250 but not exc. 500 Ltrs and removing all scale, dirt etc from bottom, side and from mouths of circulating pipes etc, complete all as specified and as directed by Engineer-in-charge. |
| 2 | Cleaning of overhead water tanks (RCC/PVC) of any description and capacity of the tank exc. 500 but not exc. 1000 Ltrs and removing all scale, dirt etc from bottom, side and from mouths of circulating pipes etc, complete all as specified and as directed by Engineer-in-charge. |
| 3 | Cleaning of overhead water tanks (RCC/PVC) of any description and capacity of the tank exc. 1000 but not exc. 2000 Ltrs and removing all scale, dirt etc from bottom, side and from mouths of circulating pipes etc, complete all as specified and as directed by Engineer-in-charge. |
| 4 | S&F in repairs 15mm ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms) and fixed in position complete all as per specified and as directed by Engineer-in-charge. |
| 5 | S&F in repairs 20mm ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210 grams) and fixed in position complete all as per specified and as directed by Engineer-in-charge. |
| 6 | S&F in repairs 25mm ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 25mm-455gms) and fixed in position complete all as per specified and as directed by Engineer-in-charge. |
| 7 | Dismantling unserviceable water storage tanks of capacity exc. 250 but not exc. 500 ltrs and removing to store or from site complete all as specified and as directed by Engineer-in-charge. |
| 8 | Dismantling unserviceable water storage tanks of capacity exc. 500 but not exc. 1000 ltrs and removing to store or from site complete all as specified and as directed by Engineer-in-charge. |
| 9 | Dismantling unserviceable water storage tanks of capacity exc. 1000 but not exc. 2000 ltrs and removing to store or from site complete all as specified and as directed by Engineer-in-charge. |
| 10 | S&F rotational moulded polyethylene water storage tanks double layered ISI Marked (cylindrical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position all as specified and directed in SSR Pt I. |
| 11 | S&F rotational moulded polyethylene water storage tanks double layered ISI Marked (cylindrical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position all as specified and directed in SSR Pt I. |
| 12 | S&F rotational moulded polyethylene water storage tanks double layered ISI Marked (cylindrical, vertical with closed top) of 2000 Ltrs capacity hoisted and fixed in position all as specified and directed in SSR Pt I. |
| 13 | Taking out old existing galvanised iron water mains 15 mm bore (including all fittings) with spigot and socket ends and fittings for re-use in the work and removing unserviceable pipes and fittings from site complete all as per specified and as directed by Engineer-in-charge. |
| 14 | Taking out old existing galvanised iron water mains 20 mm bore (including all fittings) with spigot and socket ends and fittings for re-use in the work and removing unserviceable pipes and fittings from site complete all as per specified and as directed by Engineer-in-charge. |
| 15 | Taking out old existing galvanised iron water mains 25 mm bore (including all fittings) with spigot and socket ends and fittings for re-use in the work and removing unserviceable pipes and fittings from site complete all as per specified and as directed by Engineer-in-charge. |
| 16 | S&F GI tube 15 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge. |
| 17 | S&F GI tube 20 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge. |
| 18 | S&F GI tube 25 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge. |
| 19 | Re-fixing old 15 mm bore steel water tubing and connection in new or old position including fittings, threading, cleaning for refixing to walls, ceiling or laid in floors complete all as per specified and as directed by Engineer-in-charge. |
| 20 | Re-fixing old 20 mm bore steel water tubing and connection in new or old position including fittings, threading, cleaning for refixing to walls, ceiling or laid in floors complete all as per specified and as directed by Engineer-in-charge. |
| 21 | Re-fixing old 25 mm bore steel water tubing and connection in new or old position including fittings, threading, cleaning for refixing to walls, ceiling or laid in floors complete all as per specified and as directed by Engineer-in-charge. |
| 22 | Cutting chase, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, and cutting chase for concealed water tubing or concealed conduit wiring etc and making good cutting n exc 10cm girth, complete all as per specified and as directed by Engineer-in-charge. |
| 23 | S&F in repair gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe of 15 mm bore including dismantling unserviceable one complete all as per specified and as directed by Engineer-in-charge. |
| 24 | S&F in repair gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe of 20 mm bore including dismantling unserviceable one complete all as per specified and as directed by Engineer-in-charge. |
| 25 | S&F in repair gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe of 25 mm bore including dismantling unserviceable one complete all as per specified and as directed by Engineer-in-charge. |
| 26 | S&F in repairs 15 mm bore Chromium plated fancy type bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge. |
| 27 | S&F in repair Chromium plated fancy type 15 mm bore stop valve cast copper alloy, with crutch or butterfly handle, screwed down, high pressure screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-charge. |
| 28 | S&F in repair cromimum plated health faucet (Easy flex Chrome Hose, Handset, ABS Body & Bracket) shower with CP flexible pipe up 15 mm bore with 1.00 m long Easy Flex tube in chrome finish, complete all as per specified and as directed by Engineer-in-charge. |
| 29 | S&F in repair 15 mm bore Wall Mixer with non-telephonic chromium plated cast copper, CP alloy with crutch or butterfly handle screwed for iron pipe or for brass ferrule, complete all as per specified and as directed by Engineer-in-charge. |
| 30 | S&F in repair 15mm dia bore pillar tap cast copper alloy with capston heads chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as per specified and as directed by Engineer-in-charge. |
| 31 | Demolition of brick work built in any cement mortar complete all as specified and as directed by Engineer-in-charge. |
| 32 | M&L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in in CM (1:6), complete all as specified and as directed by Engineer-in-charge. |
| 33 | S&F in repair tank cover for PVC tank (500 / 1000 / 2000 Ltrs) complete all as per specified and as directed by Engineer-in-charge. |
| 34 | M&L for reinforced cement concrete (nominal mix) type B1 1:2:4 using 20mm graded stone in slab supported on walls for water staging complete all as per specified and as directed by Engineer-in-charge. |
| 35 | M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge. |
| 36 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge. |
| 37 | M&L 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge. |
| 38 | M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 39 | S&F in repair PVC connection 15mm dia size with PTMT nuts of length 600mm, complete all as specified and as directed by Engineer-in-charge. |
| 40 | S&F in repair Vitreous china wash basin white, flat back, size 450 X 300 mm excluding tap waste but incl bracket, 32 mm CP waste coupling and incl cutting for and pinning in ends of brackets but exclusive of supply waste pipe, complete all as per specified and as directed by Engineer-in-charge.Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. Please Enable Macros to View BoQ information |