| 1 | Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as directed. |
| 3 | M & L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 4 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 5 | M&L for PCC 1:3:6 Type C-2 ( Using 40mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 6 | M & L for PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in surface channel or drain including necessary form work complete all as specified and as directed. |
| 7 | M & L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in benching and coping, pole coping, cills, hold fasts, fixing of post, water trough etc. including necessary formwork (straight or curved) complete all as specified and as directed. |
| 8 | M & L for 100 mm thick PCC 1:2:4, type B2 (using 40 mm graded crushed stone aggregates) as in path / paving / hard standing / floor and finished the surface even and fair without using extra cement complete all as specified and as directed. |
| 9 | M & L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 150mm thk Cement concrete complete all as specified and as directed. |
| 10 | M & L for forming contraction (dummy) joints 65mm deep x10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed. |
| 11 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 12 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 13 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 14 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 15 | M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 16 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 17 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 18 | M&L for preparation of old plastered surfaces of walls and applying one coat of cement based paint complete all as specified and as directed. |
| 19 | M&L for preparation of old undecorated plaster surfaces of wall and applying One coat Acrylic exterior weather coat paint complete all as specified and as directed. |
| 20 | Demolition of stone slab and tiles of any description or thickness in floor, apron etc laid, bedded and pointed in cement mortar complete all as specified and as directed. |
| 21 | M&L for pre painted, polished chequered cement concrete tiles in floor, area exc 0.06 Sqm but not exc 0.11 Sqm, 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 15 mm thick cement mortar (1:6) complete all as specified and as directed. |
| 22 | Refixing only old serviceable chequered cement concrete tiles as obtained from dismantling of tile including screed bed of 15 mm thick cement mortar (1:6) complete all as specified and as directed. |
| 23 | M&L Broken glass coping on top of walls in cement mortar 1:3 complete all as specified and as directed. |
| 24 | S & F 60 mm thick machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 M-35 Grade over and including 50 mm thick sand bed complete all as specified and as directed. |
| 25 | Refixing only old serviceable interlocking paver block 60mm thick as obtained from dismantling of paver including 50 mm thick sand bed complete all as specified and as directed. |
| 26 | S & F 80 mm thick machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 M-40 Grade over and including 50 mm thick sand bed complete all as specified and as directed. |
| 27 | Refixing only old serviceable interlocking paver block 80mm thickas obtained from dismantling of paver including 50 mm thick sand bed complete all as specified and as directed. |
| 28 | M & L for Heavy duty outdoor floor/parking tiles of size exc 0.11 Sqm but n exc 0.22 Sqm, thickness 10mm to 12mm thick, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 29 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., complete all as specified and as directed. |
| 30 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and as directed. |
| 31 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed. |
| 32 | Dismantling fencing wire mesh of any type complete all as specified and as directed. |
| 33 | Dismantling posts or struts embedded in concrete (wood, steel or R.C.C.) any section, including taking out embedded portion Concrete, brick work masonry, etc.and making good disturbed ground complete all as specified and as directed. |
| 34 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and as directed. |
| 35 | S&F mild steel angle iron post & strut etc. in fencing including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 GdeE-165 complet all as specified and as directed. |
| 36 | Supply only chain link fencing wire mesh of any size or type, made with 4 mm dia mild steel galvanised wire complete all as specified and as directed. |
| 37 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolt etc including provision of binding wire complete all as specified and as directed |
| 38 | M & L for Mild steel round barbs 10 mm dia and over cut to length, bent to shape required for securing chain link fencing cut to length bent to shape required including binding bolting etc complete confirming to Fe-410-W (Gde.E-250) Part- I quality-A complete all as specified and directed. |
| 39 | S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and diameter of shank 5 to 10mm completed all as specified and as directed. |
| 40 | S & F galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia bars at 75 mm spacing and straining and fixing to RCC / steel post etc., including securing or tying at crossing with and providing of galvanized mild steel wire, staples or steel pins, etc., (each line of wire to be measured separately) including dismantling of old barbed wire complete all as specified and as directed. |
| 41 | M&L for Restraining & resecuring only steel barbed wire including making good staples etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |