| 1 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees having girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. A In area of light jungle |
| 2 | Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 metres. Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per relevent clauses of section-300 of specification. |
| 3 | Excavation in Hard Rock with disposal upto 1000 metres Excavation for roadway in hard rock with rock breakers i/c breaking rock or by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, loading and disposal of cut road with all lifts and leads upto 1000 metres and as per relevent clauses of section-300 of specification. |
| 4 | Construction of Embankment with Material Deposited from Roadway Cutting Construction of embankment with approved materials having CBR>7 deposited at site from roadway cutting and excavation from drain or foundation of structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300. |
| 5 | Embankment/ Sub Grade Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300. |
| 6 | Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller as per clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. (ii) For 37.5 mm maximum size |
| 7 | Providing and laying reinforced cement concrete pipe NP-4 for service ducts below concrete pavement. a) 300 mm Dia |
| 8 | Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting on OMC using vibratory roller of 80 to 100 kN static weight. Field compaction shall be done in corresponding layers of carriage way thickness and meet the requirements of MDD to achieve compaction (98% -100%) as per relevant clause of 408. (A) Hard Shoulders (CBR value >12) |
| 9 | Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc (i) 5th kilometre stone (precast) |
| 10 | Ordinary Kilometer stone (Precast) |
| 11 | Hectometer stone (Precast) |
| 12 | Boundary pillar Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting. |
| 13 | Metal Beam Crash Barrier Type - A, \\"W\\" : Metal Beam Crash Barrier (Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, however 5 spaces of 600mm each between vertical post and 5 spaces of 900mm each between vertical post will be kept adjacent to RCC parapet/ concrete crash barrier in accordance to figure 9.14 of the IRC-SP: 73-2018, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5mm, 330 mm long complete as per clause 811) and treatment for metal beam cresh barrier on approach shall be modified eccentric loader terminal arrangement as shown in figure 9.12 of IRC- SP : 73-2018 End portion of metal beam crash barrier shall be flared outside by 1.25 mtr. Distance in last section of 8 mtr. Length. Departure side it shall be trailing terminal (TT) arrangement as shown in figure 9.13 of the IRC SP 732018.End portion of metal beam crash barrier shall be flared outside by 0.35 mtr. Distance in last section of 8 mtr. length |
| 14 | Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2022 clause 6.7.4.3 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts (ii) 90cm equilateral triangle |
| 15 | 60cm equilateral triangle |
| 16 | 60cm circular |
| 17 | 80x60mm rectangular |
| 18 | 60x60cm square |
| 19 | 90cm high octagon |
| 20 | Direction and Place Identification signs upto 0.9 sqm size board.Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2022 clause 6.7.4.3 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on 2 nos. of MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. |
| 21 | Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade or drainage layer with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver finisher with electronic sensor, compacting with 8- 10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect. |
| 22 | Construction of un-reinforced, dowel jointed, plain cement concrete pavement with M-40 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with electronic sensor slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc. including groove cutting for width of 4 mm- 6mm and 1/3rd depth of PQC within 8-10 hrs of placing/ finishing of PQC including cleaning of groove and providing approved sealant filling etc. as per clause 602.2.10 and 600.10 and IRC-57-2006 as per drawing and as per specification. |
| 23 | Providing and fixing Steel in dowel bar and tie rod including craddle, laps etc. complete required as per design. (b) 'Tor steel confirming to IS: 1786:2008 |
| 24 | (a) Mild steel confirming to IS: 432:1982 |
| 25 | Construction of un-reinforced, dowel jointed, plain cement concrete pavement with M-30 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with electronic sensor slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc. |
| 26 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beeds on Concrete surface. 'Providing and applying (Cleaning of concrete surface and after applying Concrete primer) thermoplastic compound having composition of binder (Regin) minimum 18%, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thickincluding drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35 along with concrete primer. The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. Note: - The guarantee of Thermoplastic should be minimum 3 Years. |
| 27 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead up to 1000 meters. (i) Lime /Cement Concrete B Cement Concrete Grade M-15 & M-20 |
| 28 | Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in I Ordinary soil ( including back filling with approved material) (i) Depth upto 3 m |
| 29 | Ordinary rock (not requiring blasting (ii) 3 m to 6 m depth |
| 30 | Hard rock (blasting Prohibited ) |
| 31 | Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100. |
| 32 | Providing and Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. (B) 1000 mm dia |
| 33 | Supplying, fitting and placing Mild steel reinforcement complete in sub-structure as per drawing and technical specification and as per relevant clause of section 1600. |
| 34 | Providing and Laying Reinforced Cement Concrete Pipe NP 4 /prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4 /prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. (B) 1000 mm dia |
| 35 | Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with. With Batching Plant, (Pan Type or Twin Shaft type) Transit Mixer and Concrete Pump PCC Grade M20 |
| 36 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. (B) PCC Grade M20 With Batching Plant, (Pan Type or Twin Shaft type)Transit Mixer and Concrete Pump |
| 37 | RCC Grade M25 With Batching Plant, (Pan Type or Twin Shaft type)Transit Mixer and Concrete Pump 1 Height up to 5 m |
| 38 | Supplying, fitting and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications and as per relevant clause of section 1600. FE 500 |
| 39 | Supplying, fitting and placing HYSD bars reinforcement in superstructure complete as per confirming to IS 1786:2000 drawing and technical specifications as per relevant clauses of section 1600 (i) FE 500 |
| 40 | Providing and Placing Reinforced/Prestressed cement concrete insuperstructure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in (B) RCC Grade M25 With Batching Plant (Pan Type or Twin Type Shaft type), Transit Mixer and Concrete Pump (i) Solid Slab 1 Height up to 5 m |
| 41 | Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398. |
| 42 | Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications. |
| 43 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78. (A) Granular material |
| 44 | Providing and laying suitable designed Filter material underneath pitching in slopes complete as per drawing and Technical specification |
| 45 | Providing and laying Cement concrete wearing coat 75 mm thick with M-30 grade concrete with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 19 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with static paver, spread, compacted and finished with power trowel in a continuous operation including provision of admixtures as approved, curing compound, finishing to lines and grades as per drawing but including cost of steel etc. including reinforcement, texuring with texuring brush complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications. |
| 46 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification and as per relevant clauses of section 1700 |
| 47 | Reinforced cement concrete non-structural approach slab (Grade of concrete M 30) as per MOST standard drawing including reinforcement and formwork complete as per drawing and Technical specification and as per relevant clauses of section 1500, 1600, 1700 and clause 2704 of specifications. |
| 48 | Construction of RCC railing with precast rails and cast in situ vertical post of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post at expansion joints of superstructure for expansion, complete as per approved drawings and technical and as per relevant clauses of sections 1500, 1600, 1700 and clause 2703 of specifications (as per MoST specification drawing SD/202 or SD/305) |
| 49 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications. |
| 50 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces |
| 51 | Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with. With Batching Plant, (Pan Type or Twin Shaft type) Transit Mixer and Concrete Pump PCC Grade M15 |
| 52 | Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with. With Batching Plant, (Pan Type or Twin Shaft type) Transit Mixer and Concrete PumpRCC Grade M20 |
| 53 | Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer–in-Charge, upto 90 metre depth below ground level. All types of soil upto 90 metre depth. 200 mm dia. |
| 54 | Rocky strata including Boulders. Beyond 90 metre depth. 200 mm dia |
| 55 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including requiredhire and labour charges, fittings and accessories etc. all complete,for all depths, as per direction of Engineer-in-Charge. 200 mm nominal size dia. |
| 56 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia |
| 57 | Providing and fixing M.S. clamp of required dia made of 100 x10 mm flat to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 200 mm clamp. |
| 58 | Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well. Filter of 32 mm dia meter |
| 59 | Providing and placing in position hand pump of Indiamark II of approved quality for 40 mm diameter G.I. pipe complete with all accessories. |
| 60 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 61 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-Charge. |
| 62 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS: 2800 (part I). 200 mm dia |
| 63 | Dismantling of existing overhead ACSR, AAAC, GI, conductor and making the site clear i/c transportation to required destination within township. |
| 64 | Erection of RS Joist pole/'H' beam/steel tubular/ steel rail pole of length 7 metres but not exceeding 10 metres in cement concrete 1:3:6 (1 cement : 3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required. |
| 65 | PCC pole 9.1 meter Long 280 kg |
| 66 | Supplying and drawing all aluminium alloy conductor (AAAC) of approved make conforming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles (if any). AAAC 0.05 sq inch (55 sq.mm Al. EQ.)- (Rabbit) |
| 67 | Supplying and erection of stay set complete (galvanized) 19mm. dia x 1.8 metre long stay rod anchor plate of size 300 mm x 300 mm x7.5mm thimble stay clamp, turn buckle (19mm dia x 600mm), 7/4.00mm dia G.I. stay wire etc. in cement concrete M- 10 (1 Cement: 3 Coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. |
| 68 | Supplying and drawing guard wire/earth wire/bearer wire 13 sq mm (4mm. dia) G.I. including stringing, binding at existing insulators or brackets, jointing, jumpering, connecting & cradle etc. as required and clearing of obstacles (if any |
| 69 | Supplying and erection of single piece nonlinear resistor type lighting arrestor (set of 3 nos) for 3 wire, 11KV overhead lines/sub-station with rated voltage of 9KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washer etc. as required. |
| 70 | Supplying installing, testing & commissioning of outdoor H.T., AB switch assembly set gang operated with brass contact parts, including required GI pipe operating rod, handle & locking arrangement on On-Off position conforming to IS complete with required material and installing on existing DP structure to complete the job as required as per specification.(Set of 3 nos.) |
| 71 | Supplying and erection of stay set complete (galvanized) with 16mm dia x1.8 metre long stay anchor plate of size 200mm x 200mm x 6.0mm thimble stay clamp turn buckle 19mmx600mm, 7/3.15mm dia G.I. stay wire etc. in cement concrete M-10 (1 cement: 3 coarse and: 6 grinded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. |
| 72 | Supply, fabrication and erection of angle/channel/flat iron fitting for overhead line & sub-station etc such as 'D' bracket, cross arms, top clamp, 'V' cross arms, back/support clamp or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification. |
| 73 | Supplying and erection of 11KV (5 KN) polymer pin insulator complete with long steel head G.I. pin, nut, washer etc. as required. |
| 74 | Supplying and erection of 11KV (45 KN) Polymer disc insulator for 11KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts washer etc. as required. |
| 75 | Supplying installing, testing & commissioning D.O. fuse assembly with brass part contact for 33 or 11/0.4 KV DP Structure set of 3 Nos. with fuse barrel i/c required fuse element & other materials as per specification on existing D.P. structure as required. |
| 76 | Supply, fixing, testing & commissioning wall/ floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & Specification. |
| 77 | Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification.Digital Ampere Metre with CTs with selector switch |
| 78 | Multifunction Meter |
| 79 | Aluminium bus bar strips with PVC sleeves |
| 80 | 3x50 sq.mm, 1x16(st. light), 1x35(insulated neutral messenger) |
| 81 | Supplying & fixing of aerial bunch cable accessories suspension clamp i/c required attachment for single core cable of approved make on pole with clamp, necessary material as per specification for required size. |
| 82 | Supplying &fixing of aerial bunch cable accessories tension clamp (dead end) i/c required attachment for single core cable of approved make in air with clamp, necessary material as per specification for required size |
| 83 | Supplying & fixing of waterproof insulation piercing connector for aerial bunch cable i/c required attachment for single core cable of approved make in air with necessary material as per specification of required size as mentioned below – Main:16-95sq.mm, tap:1.5-50sq.mm |
| 84 | Supplying & fixing of waterproof insulation piercing connector for aerial bunch cable i/c required attachment for single core cable of approved make in air with necessary material as per specification of required size as mentioned below –Main:50-150sq.mm, tap:6-50sq.mm |
| 85 | Supplying &fixing of spring loaded busbar screwless connector with enclosure of approved make including required clamp, nut, bolt, connection, testing as per specifica to complete the job.Single Phasetion1Ph, 1In+5 Out |
| 86 | Dismantling of existing H- Beam/RS Joist/PCC/Rail pole i/c accessories such as cross arms, top clamp, V- cross arms, strut, stay & conductor/cable/guarding span complete. The material should be transport & handed over to MPMKVVCL/PWD store. |
| 87 | Earthing with G.I. earth pipe 4.5 metre long and 40 mm dia with masonry encloser in cement mortar, cover plate having locking arrangement on the top etc. (but without charcoal or coke and salt) complete as required |
| 88 | Add Extra for using salt and charcoal/ coke for pipe earth electrode as required including excavation & refilling.Excavation 2.5 cum by manual labour |
| 89 | Shifting, erection, & commissioning of 25/63/100/200/315/500 KVA (11/0.433 KV) distribution transformer on existing structure including Bi-metallic clamp, ACSR/AAAC Conductor i/c colour code sleeve, for connection from H.T. Line to transformer as required as per specification Please Enable Macros to View BoQ information |