| 1 | Part A - Civil worksDismantling doors, windows and clear storey openings (steel /wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100 m lead (full windows) Of area 3.00 SqM and below |
| 2 | Dismantling doors, windows and clear storey windows (steel / wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100 m lead (full windows) Of area beyond 3.00 Sq.M |
| 3 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable materials and disposal of unserviceable materials within 200 m lead |
| 4 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 100 m lead For thickness of tiles above 10 mm and up to 25 mm. Note : Bedding mortor also to be removed along with tiles. |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 100 m lead For thickness of tiles above 25 mm and up to 40 mm |
| 6 | Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge |
| 7 | Dismantling plain cement concrete manually / by mechanical means carefully without damaging adjacent structures including disposal of debris within 200 m lead as per direction of Engineer-in charge. |
| 8 | Dismantling of RCC works including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge. |
| 9 | Dismantling old plaster / skirting carefully , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 100 m lead. |
| 10 | Demolishing Stone rubble masonry (In cement mortar) manually / by mechanical means carefully without damaging adjacent structures including stacking of serviceable materials and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge. |
| 11 | Dismantling steel work in single sections including dismantling and stacking within 100 m lead In R.S Joists, Angles etc. |
| 12 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismantling and stacking within 100 m lead |
| 13 | Dismantling Aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplaus material and stacking of serviceable materials within 100 m lead as directed by the Engineer-in-charge |
| 14 | Dismantling brick bat coba cement based water proofing over roof and chajjas carefully without damaging adjacent structures including lowering and stacking of materials and dispoal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge |
| 15 | Lead charges for debris for lead Exceeding 2 KM but not exceeding 3 KM, by mechanical transport including loading, unloading, stacking / levelling etc. |
| 16 | Lead charges for debris for lead Exceeding 3 KM but Not exceeding 4 KM, by mechanical transport including loading, unloading, stacking / levelling etc.Note: The rates in respect of above items are applicable for NET Quantities arrived at after making deduction for voids @ 30% from corresponding TRUCK Measurement. |
| 17 | Earth work excavation by mechanical means (Hydraulic excavator) / manual means in all types of soil other than soft and hard rock, dressing the sides of foundation, ramming of bottom etc. including shoring and dewatering (if necessary) and refilling with selected excavated earth in layers of not more than 500 mm thick, each layer well rammed and consolidated including disposing the surplus earth within a distance of 200 m all as per specifications including clearing Jungle, uprooting of vegetation, grass, etc. complete and as directed by the Engineer-in-charge. |
| 18 | From 0.00 to 1.50 m depth from Average Ground Level |
| 19 | From 1.50 to 3.00 m depth from Average Ground Level |
| 20 | Lead charges for soil for lead exceeding 3 KM but not exceeding 4 KM, by mechanical transport including loading, unloading, stacking / levelling etc.Note: The rates in respect of above item are applicable for NET Quantities arrived at after making deduction for voids @ 20% from corresponding STACK / TRUCK Measurement |
| 21 | Providing and laying in position cement concrete of 1:3:6 (1 cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) including consolidation, finishing, curing etc. complete as per specificationsand drawings but excluding the cost of Form work shuttering, centering Complete at all levels.Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 22 | Providing and laying in position cement concrete of 1:2:4 (1 cement, 2 crushed sand, 4 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc. complete as per specification and drawings but excluding the cost of Formwork shuttering, centering and steel reinforcement at all Levels.Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 23 | Providing and Laying cement concrete 1:2:4 in super structure (1 cement, 2 crushed sand, 4 brick aggregates 20 mm to 40 mm) for filling sunken floors of toilet bath & kitchen admixed with proprietary water proofing compound as per manufacturer's specifications and approved by Engineer-in-charge including scaffolding, consolidation, finishing curing etc. Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 24 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-20 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticisers / super plasticisers), weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level.Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 25 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level.Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 26 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications in super structure up to 20.00 metre height. Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 27 | Extra for RCC Using Ready Mix Concrete from outside project area including transporting and pumping from approved batching plants . |
| 28 | Providing , centering ,shuttering Form work using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings specifications and as directed by the Engineer-in-charge at all levels |
| 29 | For Sub structure |
| 30 | For Super Structure |
| 31 | Extra for circular & curved shuttering in sub structure |
| 32 | Extra for circular & curved shuttering in super structure |
| 33 | Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings. Steel supplied by the Department. Notes : 1. The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers and also testing third party from approved laboratories with out any extra cost. 2. Binding wire required for the work will have to be supplied by the contractor at their own cost and will not be measured for payment. 3. Cover blocks shall be of same grade of concrete. |
| 34 | Using TMT bars of specified grades of all sizes. TMT bars to be supplied by the contractor manufactured by approved brands of BARC only Confirming to IS:1786 |
| 35 | Providing Structural steel work in M.S. Plain Plates and chequrred Plates for Embedded Parts, Trench Covers, Connection plates etc.including cutting, hoisting, fixing in position and applying a priming coat of approved zinc chromate steel primer etc. including cost of structural steel Plates, welding all labour charges etc. complete as per drawings and specifications. Using materials manufactured by approved brands of BARC only. All test reports to be provided along with the supply of the materials Note: 1) Structural steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2)Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate.(3) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (4) Edges of plates shall be grinded to uniform smooth finish. '(5) Full length welding shall be carried out as directed by the EIC. |
| 36 | Providing Structural steel work using angles, channels, joists and other sections, welded and / or bolted in built up sections for trusses , structural steel floors, frame works, monorails and other structures including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Note: 1) Structural steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2)Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate.(3) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (4) Edges of plates shall be grinded to uniform smooth finish. '(5) Full length welding shall be carried out as directed by the EIC. |
| 37 | Up to and including 300 mm Joists, 350 mm channels, and below sections Using materials of approved equivalent quality/ product meeting technical parameters, confirming to IS 2062. All test reports to be provided along with the supply of the materials. |
| 38 | Providing, supplying, cutting, welding, fabricating, hoisting and fixing in position structural steel members like trusses, purlins, posts etc. using MS hollow / circular / square / rectangular tubular sections including appyling a coat of Zinc chromate primer of approved make all as per specifications, drawings and as directed by the Engineer in chargeNote : Grade of structural steel E 310, confirming to IS 2062-2011 , Minimum yield strength 310 N/mm2.1) Structural steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2)Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate.(3) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (4) Edges of plates shall be grinded to uniform smooth finish. '(5) Full length welding shall be carried out as directed by the EIC. |
| 39 | Providing and fixing hand rail using 304 grade Stainless Steel pipes of approved size and make and quality by welding, mirror / matt polishing, fixing at site etc. for balcony railing & staircases railing including special sections as per drawings, specifications. complete as directed by the Engineer-in-charge |
| 40 | Providing and constructing Brickwork in cement mortar 1:4 using crushed sand with Flyash / Flyash Lime bricks with minimum 70 kg / Sq. cm strength of approved make and size in Sub structure including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings. |
| 41 | Providing and constructing Brickwork in cement mortar 1:4 using crushed sand with Flyash/ Flyash Lime bricks with minimum 70 kg/ sq.cm strength of approved make and size in super structure up to and including Floor II Level including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings. |
| 42 | Providing and constructing Brickwork in cement mortar 1:4 using crushed sand with Flyash/ Flyash Lime bricks with minimum 70 kg/ sq.cm strength of approved make and size in super structure above Floor-II level and up to and including 20 m height by lifting material by mechanical means using tower crane / manual lifting including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings. |
| 43 | Providing and constructing Half brick masonry using Flyash/ Flyash Lime bricks in suerstructure upto floor II level with minimum 70 kg / Sq.cm strength of approved make and size in partition walls in C.M 1:4 using crushed sand including scaffolding, raking out joints, curing etc. complete and with stiffners of RCC 1:2:4 (105 X 75 mm size) at every 900 mm height including form work curing etc. complete as per specifications but excluding reinforcement. (Note : Reinforcement will be paid under relevant item) |
| 44 | Providing and constructing brickwork in cement mortar 1:6 using crushed sand with Flyash/ Flyash Lime bricks with minimum 70 kg/ Sq.cm strength of approved make and size in super structure above plinth up to and including Floor II level including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings |
| 45 | Terracotta works |
| 46 | Providing and fixing terracotta blocks/ brick of approved make in different sizes conforming to relevant IS codes using polymer modified mortar and jointing with grey cement slurry including grouting with the joints with grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-incharge. |
| 47 | Providing and fixing 15 mm thick terracotta wall tiles of approved make in different sizes conforming to relevant IS codes using polymer modified mortar and jointing with grey cement slurry including grouting with the joints with white cement based tile grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-incharge. |
| 48 | Providing 12 mm thick Internal plastering in cement mortar 1:4 without cement punning (using crushed sand) finished smooth, including sieving of sand to required fineness, preparation of the surface, scaffolding, curing all as per specifications, drawings and as directed at site complete. |
| 49 | Providing 15 mm thick plastering using Ready mix internal plastering compound of approved make for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding complete all as per specifications and as directed at site by the Engineer-in-charge. |
| 50 | Providing 20 mm thick External plastering in two coats under layer 12 mm thick with C.M 1:4 (using crushed sand) finished with a top layer 8 mm thick in C. M 1:3 (using crushed sand) including approved water proofing compound @ 2% by weight of cement or as per manufacturer's specifications, sieving of sand to required fineness, scaffolding up to 10 metres height, finishing, curing etc. complete as per specifications. and as directed by the Engineer-incharge |
| 51 | Providing 20 mm thick plastering using Ready mix external plastering compound of approved make for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge |
| 52 | Providing and Laying Minimum 25 mm thick uniform shade Kotah stone treads and risers of steps, skirting, window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finish complete as per specifications, drawings and as directed by the Engineer-in-charge. |
| 53 | Extra over for nosing in steps of treads Using Kotah stone |
| 54 | Extra for nosing in steps of treads Using Kotah stone with 3 no's V groove. Note: Only Nosing length of steps will be considered for payment |
| 55 | Providing and laying minimum 25 mm thick uniform shade Kotah stone flooring over 20 mm thick (Avearge) base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing in minimum three levels to obtain mirror polish complete with base cement mortar 1:4 (using crushed sand) all as per specifications, patterns and drawings complete. |
| 56 | Providing, supplying and laying pre polished granite slab flooring / dado / Wall cladding with not less than 15-17 mm thick granite slabs over 20 mm thick base cement mortar 1:4 (using crushed sand) laid and placed with grey cement slurry including filling the joints with matching white cement based tile grout complete all as per specifications and drawings. |
| 57 | Using approved black shade |
| 58 | Using approved shades other than black |
| 59 | Extra Over for above item for flaming (Rough finish).Note: Area of flaming strips in tread only shall be measured for payment. |
| 60 | Extra over for providing edge moulding to 15-17 mm thick Granite Slab counters, Vanitis etc. including machine polishing to edge to give high gloss finish et. Complete as per design approved by Engineer-in-charge. |
| 61 | Extra over for Graphical designs in Flooring using Water Jet cutting Method /by CNC machines as per the designs given in the drawings to get Uniform sharp Joints etc all as per drawings ( Cutting length using water jet alone will be measured irrespective of width) In full body Vitrified Tile / Granite / Marble tiles. Note :1. This item will be paid only if, pattern flooring cut from full florring. 2. Cutting length of granite (irrsepective of width) will be considered for measurment. |
| 62 | Providing and laying 50 mm thick prepolished Basalt stone /Granite slab with shot blast and leather finished slabs in flooring/dado/ Wall cladding laid over 12 mm thick base cement mortar 1:3 (using curshed sand) laid and placed with grey cement slurry including filling joints with matching white cement based tile grout complete all a per speification and drawings. Please Enable Macros to View BoQ information |
| 63 | Providing and laying 50 mm thick prepolished Basalt stone /Granite slab with shot blast and leather finished slabs in flooring/dado/ Wall cladding laid over 12 mm thick base cement mortar 1:3 (using curshed sand) laid and placed with grey cement slurry including filling joints with matching white cement based tile grout complete all a per speification and drawings. Please Enable Macros to View BoQ information |