| 1 | Dismantling of existing structures like culverts, bridges, retaining walls and other sturcture comprising of masonry, cement concrete wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable materials and stacking the serviceable materials with all lifts and lead of 1000m as per Technical Specification Clause 202 Below foundation |
| 2 | Dismantling of existing structures like culverts, bridges, retaining walls and other sturcture comprising of masonry, cement concrete wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable materials and stacking the serviceable materials with all lifts and lead of 1000m as per Technical Specification Clause 202 Slab |
| 3 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. |
| 4 | Earth work in all kinds soil or ordinary soil in embankment, roads with M.D.D. not less than 1.44gm/1.65gm per cc upto 3mtr high & top 0.5mtr below sub-grade level respectively with initial lead & lift from borrow pit 5m. away from the toe line of final section including rough dressing , breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.23m in depth etc. including removing all debrises & benching old embankment complete (As per item 2(d) of AR-2006 Page-3). With mechanical lead upto 1000m |
| 5 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement as per MORD technical Specification Clause 301 and direction of the Engineer in Charge (excluding cost of excavation and transportation to site). |
| 6 | Excavation in ordinary rock using Hydraulic Excavator of 0.9 cum bucket capacity including cutting and loading in tippers,transporting to embankment site with a lift upto 1000m,trimming bottom and side slopes in accordance with requirements of lines,grades and cross-section as per Techinal Specification clause 302.3.5. |
| 7 | Excavation in Hard Rock (blasting prohibited by mechanical means) as per technical specificaation clause 302 |
| 8 | Fine dressing and turfing including transportation by mechanical means with all lead and lift and placing of turf in position and ramming with thapies and including watering and cost of all labour, materials etc. complete as per Clause 309 of MORD Specification and as per direction of the Engineer in Charge. |
| 9 | Providing Construction of granular sub-base Gr-III by providing well graded material, spereading in uniform layers with tractor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MORD Technical Specification clause 401 and as per direction of Engineer in Charge. |
| 10 | Providing, laying, spreading and compacting graded stone aggregates to Wet Mix Macadam (WMM) specification including premixing the materialnwithb water at OMC in mechanical mixer(pug Mill) , carriage of mix material by tipper to site,laying in uniform layers with paver in sub base or base course on well prepared sub-base and compacting with smooth wheel of 80-100kn roller to achive the desired density including lighting ,barricading and maintenance of diversion etc as per Tables 400.11 & 400.12 and Technical specifications clause 406. |
| 11 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MORD Technical Specification Clause 502 for low porosity surface and as per direction of Engineer-in-Charge. |
| 12 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503 of MoRD & as per direction of Engineer-in-Charge. |
| 13 | Providing, laying and rolling of open-graded premix carpet of 20 mm thickness compacted of 13.2 mm to 5.6 mm aggregates using Bitumen Emulsion(Cold Mix) @ 21.5 kg/10 sqm to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable hot mix plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of Type C as per Technical Specification Clause 508.2 of MoRD and as per direction of Engineer-in-Charge(Cold Mix Bitumen) |
| 14 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type C as per Technical Specification Clause 510 of MORD with bitumen Emulsion SS-1 laid by manual means and as per direction of Engineer-in-Charge. (COLD MIX). |
| 15 | Construction of Panelled cement concrete pavement, thickness as per design, over a prepared sub-base, with 43 grade cement or any other type as per Clause 1501.2.2, M30 (grade) coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars near approaches to bridges and culverts (expansion joints), admixtures as approved, curing of concrete slabs for 14 days, curing compound and water finishing to lines and grade as per drawing and Technical Specification Clause 1501. |
| 16 | Earthwork in excavation for foundation of structures in all types of soil as per drawing and technical specification Clause 305 and 1104 of MoRD includding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto all lead & lift, dressing of sides and bottom and back filling with excavated suitable material upto 3mt. as per direction of Engineer-in-Charge. |
| 17 | Providing and constructing well compacted drainage layer above the subgrade of roadwork with approved quality of dust free washed coarse to medium sand as per Clauses 5.8 and 6.6 of SP:20-2002. |
| 18 | Providing concrete for plain / reinforced concrete in open foundation complete as per drawing and MORD technical specification Clause 800,1100,1200 and as per direction of Engineer-in-Charge. |
| 19 | Providing and laying reinforced cement concrete M-25 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 Raft & Drain Slab |
| 20 | Providing and laying reinforced cement concrete M-25 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 Deck Slab |
| 21 | Providing and laying reinforced cement concrete M-25 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 Rib Hunch |
| 22 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 23 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 24 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) complete as per drawings and MORD technical specification Clauses 1000,1200 as per direction of the Engineer in charge In Sub-structure |
| 25 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) complete as per drawings and MORD technical specification Clauses 1000,1200 as per direction of the Engineer in charge In Super-structure & Drain Slab |
| 26 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MORD technical specification Clause 1204.3.8 and as per direction of the Engineer in charge |
| 27 | Providing and fixing 20mm thick compressible fiber board in expansion joint complete as per drawing and technical specifications including cost convyance taxes of all materials, cost of all labours, T & P required for the work etc.complete and as per direction of the Engineer -in- charge. |
| 28 | Providing and laying reinforced cement concrete NP3 pipe for culverts jointing with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1100 of MoRD & as per direction of Engineer-in-Charge. 1000 mm dia Single row |
| 29 | Providing and laying reinforced cement concrete NP3 pipe for culverts jointing with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1100 of MoRD & as per direction of Engineer-in-Charge. 1000mm dia Double row |
| 30 | Plain/reinforced cement concrete in sub-structure complete as per drawings and MORD technical specification Clauses 800,1200 and as per direction of the Engineer in charge |
| 31 | Providing and laying pitching with stone boulders on slopes laid over prepared filter media as per drawing and MORD technical specifications Clause 1300 and as per direction of the Engineer in charge |
| 32 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MORD technical specification Clauses 614, 709, 1204 and as per direction of the Engineer in charge |
| 33 | Providing and fixing of typical masonry PMGSY informatory sign board with Logo as per MORD specifications and drawing. Brick masonry board with writting area 1.5mx0.9m and 0.115m border. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 of MoRD etc. complete and as per direction of the Engineer -in- charge. |
| 34 | Providing and fixing of typical PMGSY logos made of 1.6mm thick MS sheet duly stove enameled on both side with lettering and printing arrows, border etc.will be painted with ready mixed synthetic enamel paint of superior quality in required shade & colour fixed & supported on 75mmx75mmx6mmM.S.angle 3500mm long firmly fixed to the ground by means of properly foundation with M15 grade c.c. 450x450x600mm ,600mmbelow ground level as per drawings & tech. specification clause 1701 and as per direction of the Engineer -in- charge. |
| 35 | Providing and fixing of semi-reflectorised cautionary, mandatory and iformatory sign as per IRC-67 made of 1.5mm thick MS sheet duly stove white colour in front and gray colour on back with red reflective border of 65mm width & required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 fixed & supported on 47mmx47mmx12SWG sheet tube 3050mm long firmly fixed to the ground by means of properly foundation with M15 grade c.c. 450x450x600mm ,600mmbelow ground level as per drawings & tech. specification clause 1701.2.2 and as per direction of the Engineer -in- charge. |
| 36 | Providing and fixing of semi-reflectorised cautionary, mandatory and iformatory sign as per IRC-67 made of 1.5mm thick MS sheet duly stove white colour in front and gray colour on back with red reflective border of 65mm width & required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 fixed & supported on 47mmx47mmx12SWG sheet tube 3050mm long firmly fixed to the ground by means of properly foundation with M15 grade c.c. 450x450x600mm ,600mmbelow ground level as per drawings & tech. specification clause 1701.2.2 and as per direction of the Engineer -in- charge. ii) 600mm Circular |
| 37 | Providing and fixing of semi-reflectorised direction & place identification sign as per IRC-67 made of 2mm thick MS sheet duly stove white colour in front and gray colour on back with red reflective border of 70 mm width & required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 fixed & supported on 47mmx47mmx12SWG sheet tube 3050mm long duly strenghting by 25mmx5mm flat iron on edges firmly fixed to the ground by means of properly foundation with M15 grade c.c. 450x450x600mm ,600mmbelow ground level as per drawings & tech. specification clause 1701.2.2 and as per direction of the Engineer -in- charge. |
| 38 | Providing and fixing of typical PMGSY Citizen sign board with logo as per MORD specifications and drawing. Two MS plates of 2mm thick, top & middle plate duly welded with MS flat iron 25mmx5mm size on back on edges. The flat iron frame of both plate will be welded to 2nos 75mmx75mm of 12SWG sheet tubes posts duly embeded in C.C. M-15 grade blocks of 600mmx600mmx750mm, 750mm below ground level. The top most dimond plate will be welded to middle plate by 47mmx47mm of 12SWG steel tube. All M.S. will be stove enameled on both sides. Lettering & printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quailty in required shade & colour. All sections of framed posts & steel tubes will be painted with primer & two coats of paint as per drawing clause 1701 and Annexure 1700.1 |
| 39 | Reinforced cement concrete M15 grade Kilomitre stoneof Standard design as per IRC:8 fixing in position including painting, lettering in accordance with the specifications Clause 1703 of MoRD . etc. complete and as per direction of the Engineer -in- charge. Reference Pillar |
| 40 | Reinforced cement concrete M15 grade Kilomitre stoneof Standard design as per IRC:8 fixing in position including painting, lettering in accordance with the specifications Clause 1703 of MoRD . etc. complete and as per direction of the Engineer -in- charge. TBM Pillar |
| 41 | Reinforced cement concrete M15 grade Kilomitre stoneof Standard design as per IRC:8 fixing in position including painting, lettering in accordance with the specifications Clause 1703 of MoRD . etc. complete and as per direction of the Engineer -in- charge. Fixing of Km. Stone |
| 42 | Reinforced cement concrete M15 grade Kilomitre stoneof Standard design as per IRC:8 fixing in position including painting, lettering in accordance with the specifications Clause 1703 of MoRD . etc. complete and as per direction of the Engineer -in- charge. Fixing or 200m Stone |
| 43 | Reinforced cement concrete M15 grade Kilomitre stoneof Standard design as per IRC:8 fixing in position including painting, lettering in accordance with the specifications Clause 1703 of MoRD . etc. complete and as per direction of the Engineer -in- charge. Guide Post (M-20) |
| 44 | Maintenance Routine Maintenance after completion of construction works 1st Year |
| 45 | 2nd Year |
| 46 | 3rd Year |
| 47 | 4th Year |
| 48 | 5th Year Please Enable Macros to View BoQ information |