| 1 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PS No. 647 (Make : Bajaj/Philips/Crompton/Valmont/ Transrail) |
| 2 | S/Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. . PS No. 1422 Cat AAA. (Bajaj/Philps/Havells/Crompton) |
| 3 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501 (Make-Havells/Grandley/Polycab/ Diatron/Gloster/Kalinga) b) 16 sqmm x 4 core |
| 4 | f) 50 sqmm x 3.5 core |
| 5 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making onnection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504a) 16 sqmm |
| 6 | e) 50 sqmm |
| 7 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. PS. No. 725 (B) |
| 8 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 716 |
| 9 | S/F of Copper Cable of size 2.5 mm x 3 Core. Complete in all respect (AOR) |
| 10 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (Make-CPE/Duraline/Rex/Times/Narender Plast/Pioneer)i) 90 mm dia (OD-90 mm & ID-76 mm nominal) DSR Electrical-18 pg-52, I.No.14.16.2 |
| 11 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. PS 627 |
| 12 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. E/I E/I DSR Electrical-2018. 12.38 |
| 13 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS. No. 807 f (ii) 40 A TPN |
| 14 | Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect. P.S. No. 628 |
| 15 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. DSR2018, 12.42 |
| 16 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 17 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 18 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 19 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/I (AOR) |
| 20 | Laying Old cemennt concrete interlocking paver blocks of any design/shape laid in required line, level currative colour and pattern over and including 50mm thick compacted bed of course sand filling the joint with fine sand etc. all complete as per direction of E/I (Old CC Paver block shall be supplied by the deptt free of cost) (AOR) Please Enable Macros to View BoQ information |