|
| 1 | Supply of streel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 |
| 2 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. DSR Electrical 2018/ I. No. 11.3.4 |
| 3 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. DSR Electrical 2018/ I. No. 12.42 |
| 4 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS 725 (B) |
| 5 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects. PS No. 716 |
| 6 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. DSR Electricals 2018 No. 9.3a) 2 X 16 sq. mm (9.3.1) |
| 7 | b) 2 X 25 sq. mm (9.3.2) |
| 8 | c) 4 X 16 sq. mm (9.3.29) |
| 9 | d) 3.5 x 50 sq. mm (9.3.19) |
| 10 | e) 3.5 X 70 sq. mm (9.3.20) |
| 11 | Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) DSR Electrical 2018 /Item No. 11.5 |
| 12 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 13 | Location and pin pointing of 11KV HT Cable fault exposing the same in the underground 11KV Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 14 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by expert technical staff. (AOR) |
| 15 | Repairing of 11KV Fuse wire/Jumper i/c supply & fixing of r+B32equired size conductor, fuse wires of 11KV Line/DP Structure of Transformer by taking shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, Shoes and other necessary items. (AOR) |
| 16 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR 14.16.1 a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 17 | b) 90 mm dia (OD-90 mm & ID-76 mm nominal) (14.16.2) |
| 18 | S/L of 3\\" (80mm) dia G.I. Pipe 'B' Class in the ground level including road cutting Complete in all respects as per direction of E/I DSR Electrical-18 12.38 |
| 19 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects.PS NO 627 |
| 20 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR Electrical 2018/ I.No. 12.34 |
| 21 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect.PS No 634 |
| 22 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501. 16 sqmm x 4 core |
| 23 | 25 sqmm x 2 core (AOR) |
| 24 | 16 sqmm x 2 core |
| 25 | 50 sqmm x 3.5 core |
| 26 | 70 sqmm x 3.5 core |
| 27 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making onnection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504a) 16 sqmm |
| 28 | b) 25 sqmm |
| 29 | c) 35 sqmm |
| 30 | d) 50 sqmm |
| 31 | e) 70 sqmm |
| 32 | Numbering of poles with combination of yellow and black colour paint etc complete in all recpects as per direction of E/I (AOR) |
| 33 | S/F of 11 KV Disc insulator 70 KN and fitting B&S heavy duty with clamp of cross arm fixed on HT Pole BHEL/Jai Shree/WS/RR/Make UPERC P-43 |
| 34 | S/F of 11 KV pin 12\\" long with insulator of Jai Shree/HBHEL on cross arm fixed on HT pole including all T/P etc UPERC P-39 Annexure-16 |
| 35 | Supply of 11KV Pin Isulator as per UPERC 2019/I. No. 6 page 40 |
| 36 | Supply of 11KV Pin with nut as per UPERC 2019/I. No. 7 page 39 |
| 37 | S/f of 11 KV TPMO relco/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects. UPERC P No 48 I No. 13 |
| 38 | S/F of 11 kv, 100 Amp, Drop Fuse set Channel type (3 nos) (AOR) |
| 39 | S/F of Sintex Junction box No IIGSSJB2817 of size 240x130x110mm. Complete in all respects as per direction of E/I (AOR) |
| 40 | Repair of 63/100 KVA Transformer incl. changing of HV & LV Coil, Bushing, Gasket & Fresh Transformer oil without returning of old & unservicable material. Complete in all respect as per direction of E/I. (AOR) |
| 41 | Dis/Re-fixing of 63/100 kva transformer with connection loading & unloading, cartage charge from site to repairing at worshop complete in all respects as per direction of E/I (AOR) |
| 42 | Supply & fixing of LED Strip 5 W/M with life L 70/40000 boring hours of reputed LED Make Saffran/White/green datachabe in 1M suitable for 240V AC 30 m of strip for out door use with 3 years warranty. Complete in all respects as per direction of E/I (AOR) |
| 43 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS. No. 807 f (ii) 40 A TPN |
| 44 | S/F of Copper Cable of size 2.5 mm x 3 Core. Complete in all respect (AOR) |
| 45 | Supplying and laying of Underground/Over ground laying of HDPE Pipe, OFC/Power/Data/Coxial Cable (AOR) |
| 46 | Supply and Laying of HDPE Duct (40 mm) Complete with all accessories as required. (AOR) |
| 47 | Supply of 185 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respects as per direction of E/I. . (UPERC P-28) |
| 48 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required..(DSR elect 2018 Item.N. 8.3.2 Above 120 Sqmm and upto 400 Sqmm |
| 49 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :. (UPERC P-41) 185 Sqmm |
| 50 | S/Making of Straight through joint suitable for 185 sqmm x 3 core 11KV XLPE cable as per ISS & Complete in all respects As per direction of E/I. (UPERC P-29) |
| 51 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (creator poly extrusion/duraline/rex/times/ narander plast/pioneer make). (AOR) |
| 52 | Supply and Fixing of 10-12 Mtr Lone Octagonal pole door cover hot dip galvanished & proper locking arrangement. Complete in all respect as per direction of E/I. (AOR) |
| 53 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x16sqmm complete in all respects as per direction of E/I. (AOR) |
| 54 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x25sqmm complete in all respects as per direction of E/I. (AOR) |
| 55 | Painting on Existing Street light Octagonal pole of 10-12 Mtr Height with Primer & zinc paint using spray gun including required labour, T&P etc. (AOR) |
| 56 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 57 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate moorum screening, red bajri and labour required. i) bituminious portion (AOR) |
| 58 | ii) water bound macadam (AOR) |
| 59 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 60 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 61 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/I (AOR) |
| 62 | Laying Old cemennt concrete interlocking paver blocks of any design/shape laid in required line, level currative colour and pattern over and including 50mm thick compacted bed of course sand filling the joint with fine sand etc. all complete as per direction of E/I (Old CC Paver block shall be supplied by the deptt free of cost) (AOR) Please Enable Macros to View BoQ information |